| For use with |
easySafety ES4P |
| Software |
easySoft-Safety Menu selection in German, English, French, and Italian Operating systems: Windows XP SP3, Windows 7 (32 bit + 64 bit), Windows 8 (32 bit + 64 bit) |
Information relevant for export to North America |
UL/CSA certification not required |
| Rated operational current for specified heat dissipation [In] |
|
| Heat dissipation per pole, current-dependent [Pvid] |
0 A |
| Equipment heat dissipation, current-dependent [Pvid] |
0 W |
| Static heat dissipation, non-current-dependent [Pvs] |
0 W |
| Heat dissipation capacity [Pdiss] |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
| 10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
| 10.5 Protection against electric shock |
Meets the product standard´s requirements. |
| 10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
| 10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
| 10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
| 10.10 Temperature rise |
Is the panel builder´s responsibility. |
| 10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
| 10.12 Electromagnetic compatibility |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
| 10.13 Mechanical function |
Is the panel builder´s responsibility. |
| With editor for programming language IL (Instruction List) |
Is the panel builder´s responsibility. |
| With editor for programming language LD (Ladder Diagram) |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| With editor for programming language FBD (Function Block Diagram) |
|
| With editor for programming language ST (structured text) |
|
| With editor for programming language SFC (Sequential Function Chart) |
No |
| With editor for programming language Flowchart |
Yes |
| With editor for manufacturer specific programming language |
No |
| Suitable for operating system Windows 9x |
No |
| Suitable for operating system Windows NT |
No |
| Suitable for operating system Windows 2000 |
No |
| Suitable for operating system Windows XP |
Yes |
| Suitable for operating system Windows ME |
No |
| Suitable for operating system Windows CE |
No |
| Suitable for operating system Linux |
Yes |
| Suitable for operating system Windows Vista |
Yes |
| Suitable for operating system Windows 2003 Server |
No |
| Suitable for operating system Windows 7 |
No |
| Suitable for operating system Windows 8 |
No |
| Suitable for other operating system |
Yes |
| Object library |
No |
| Integrated diagnosis function |
Yes |
| Integrated configuration function |
Yes |
| Integrated evaluation function |
No |
| Integrated application configuration function |
Integrated |
| Integrated data detection function |
Yes |
| Integrated communication function |
Yes |
| Technology function integrated |
Yes |
| Put into operation function integrated |
Yes |
| Simulation function integrated |
Yes |
| Integrated motion function |
Yes |
| Integrated analysis function |
No |
| Integrated position function |
Yes |
| Maintenance function integrated |
Yes |
| In accordance with IEC 1131-3 (DIN EN 61131-3) |
No |
| Suitable for safety functions |
Yes |
| SIL according to IEC 61508 |
No |
| North America Certification |
Yes |