For use with |
easySafety ES4P |
Software |
easySoft-Safety Menu selection in German, English, French, and Italian Operating systems: Windows XP SP3, Windows 7 (32 bit + 64 bit), Windows 8 (32 bit + 64 bit) |
Information relevant for export to North America |
UL/CSA certification not required |
Rated operational current for specified heat dissipation [In] |
|
Heat dissipation per pole, current-dependent [Pvid] |
0 A |
Equipment heat dissipation, current-dependent [Pvid] |
0 W |
Static heat dissipation, non-current-dependent [Pvs] |
0 W |
Heat dissipation capacity [Pdiss] |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
With editor for programming language IL (Instruction List) |
Is the panel builder´s responsibility. |
With editor for programming language LD (Ladder Diagram) |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
With editor for programming language FBD (Function Block Diagram) |
|
With editor for programming language ST (structured text) |
|
With editor for programming language SFC (Sequential Function Chart) |
No |
With editor for programming language Flowchart |
Yes |
With editor for manufacturer specific programming language |
No |
Suitable for operating system Windows 9x |
No |
Suitable for operating system Windows NT |
No |
Suitable for operating system Windows 2000 |
No |
Suitable for operating system Windows XP |
Yes |
Suitable for operating system Windows ME |
No |
Suitable for operating system Windows CE |
No |
Suitable for operating system Linux |
Yes |
Suitable for operating system Windows Vista |
Yes |
Suitable for operating system Windows 2003 Server |
No |
Suitable for operating system Windows 7 |
No |
Suitable for operating system Windows 8 |
No |
Suitable for other operating system |
Yes |
Object library |
No |
Integrated diagnosis function |
Yes |
Integrated configuration function |
Yes |
Integrated evaluation function |
No |
Integrated application configuration function |
Integrated |
Integrated data detection function |
Yes |
Integrated communication function |
Yes |
Technology function integrated |
Yes |
Put into operation function integrated |
Yes |
Simulation function integrated |
Yes |
Integrated motion function |
Yes |
Integrated analysis function |
No |
Integrated position function |
Yes |
Maintenance function integrated |
Yes |
In accordance with IEC 1131-3 (DIN EN 61131-3) |
No |
Suitable for safety functions |
Yes |
SIL according to IEC 61508 |
No |
North America Certification |
Yes |