Switched-mode power supply unit, 100-240VAC/24VDC/12VDC, 0.35A/0.02A, 1-phase, controlledThe primary cycled and controlled switched-mode power supply units supply a safe low voltage (SELV according to EN60950) with radio interference level B according to EN55011 and EN55022. They have been tested for use in industrial as well as public networks. Overload safety and permanent short-circuit strength ensure for a high safety of the devices. Rated input voltage at 50/60 Hz: 100-240VAC, rated output voltage: 24V/12VDC, rated output current: 0.35A/20 mA
Switched-mode power supply unit, 100-240VAC/24VDC/12VDC, 0.35A/0.02A, 1-phase, controlled
The primary cycled and controlled switched-mode power supply units supply a safe low voltage (SELV according to EN60950) with radio interference level B according to EN55011 and EN55022. They have been tested for use in industrial as well as public networks. Overload safety and permanent short-circuit strength ensure for a high safety of the devices. Rated input voltage at 50/60 Hz: 100-240VAC, rated output voltage: 24V/12VDC, rated output current: 0.35A/20 mA
Product range | Control relay easyRelay Multi-function-display MFD-Titan |
Product range | Switched-mode power supply units easyPOW |
Basic function accessories | Accessories for remote monitoring unit |
Description | primary chopper controlled |
Phases | Single-phase |
Input voltage range | 85 - 264 V AC |
Nominal input voltage | 100 - 240 V AC |
Rated output voltage | 24 V DC (± 3%) 12 V DC (± 4%) |
Rated output current | 0.35 0.02 A |
For use with | easy500 easy700 easy800 MFD-CP8 EC4P ES4P |
Standards | EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27 |
Dimensions (W x H x D) | 35.5 (2 PE) x 90 x 58 mm |
Weight | 0.1 kg |
Mounting | Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Solid | 0.2/4 (AWG 22 - 12) mm2 |
Flexible with ferrule | 0.2/2.5 (AWG 22 - 12) mm2 |
Standard screwdriver | 0.8 x 3.5 mm |
Max. tightening torque | 0.6 Nm |
Operating ambient temperature | -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Condensation | Take appropriate measures to prevent condensation |
Storage | - 40 - 70 °C |
Relative humidity, non-condensing (IEC/EN 60068-2-30) >Air humidity, non-condensing, min. |
5 % |
Relative humidity, non-condensing (IEC/EN 60068-2-30) >Air humidity, non-condensing, max. |
95 % |
Air pressure (operation) | 795 - 1080 hPa |
Max. installation altitude above sea level, observe derating with higher altitudes | 2000 m |
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP20 |
Vibrations (IEC/EN 60068-2-6) >Constant amplitude 0.15 mm |
10 - 57 Hz |
Vibrations (IEC/EN 60068-2-6) >Constant acceleration 2 g |
57 - 150 Hz |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms | 18 Impacts |
Drop to IEC/EN 60068-2-31 [Drop height] | 50 mm |
Free fall, packaged (IEC/EN 60068-2-32) | 1 m |
Mounting position | Vertical or horizontal |
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD) >Air discharge |
8 kV |
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD) >Contact discharge |
6 kV |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 | 10 V/m |
Radio interference suppression | EN 55011 Class B, EN 55022 Class B |
Burst pulses (IEC/EN 61000-4-4, level 3) | 2 kV |
Power pulses (surge) (IEC/EN 61000-4-5) | 2 (supply cables, symmetrical) kV |
High-energy pulses (surge) (IEC/EN 61000-4-5, level 2), 24 V | 0.5 (outgoer cables symmetrical, EASY…DC) kV |
Immunity to line-conducted interference to (IEC/EN 61000-4-6) | 10 V |
Surge voltage (EN 50178), 24 V | 6 kV |
Clearance in air and creepage distances | EN 50178 |
Insulation resistance | EN 50178 |
Protection class Uout to Uin | Class II to IEC 60536 |
Potential isolation primary/secondary | Yes, SELV (VDE 0100 Part 410; IEC 60364-4-41, HD 384.4.41 S2) EN 60950, EN 50178 |
Rated input voltage DC | 100/120/230/240 (-15/+10 %) V |
Protective switches AC | FAZ-C1/1 or FAZ-B6/1 |
DC protective switches | FAZ-C2/1-DC |
Voltage range | 85 - 264 V AC |
Frequency range | 47 - 63 Hz |
Mains failure bridging 115/230 V (IEC/EN 61000-4-11) | > 10/> 20 ms |
Fuse 115/230 V | 1.5 slow A |
Efficiency | > 80 % |
Power consumption | Normally 7 W |
Power loss [P] | Normally 1 W |
Input current nominal 115/240 V | Approx. 170/80 mA |
Inrush current at 25 °C 230 V | < 5 A |
12 V DC (reference voltage) >Rated value |
12 V DC |
12 V DC (reference voltage) >Tolerance |
± 4 % |
12 V DC (reference voltage) >Switching peaks |
< 7 mVSS |
12 V DC (reference voltage) >Effect of input voltage |
± 1 % |
12 V DC (reference voltage) >Effect with 25 - 100 % load change |
± 1 % |
24 V DC >Rated value |
24 V DC |
24 V DC >Tolerance |
± 3 % |
24 V DC >Switching peaks 115/230 |
< 50/30 mVPP |
24 V DC >Effect of input voltage |
± 1 % |
24 V DC >Effect with 25 - 100 % load change |
± 1 % |
12 V DC (reference voltage) >Output current |
0 - 20 mA |
12 V DC (reference voltage) >Effectiveness of current limitation |
20 mA |
12 V DC (reference voltage) >Reduction of output voltage after current limitation |
< 12 V |
12 V DC (reference voltage) >Overload proof |
Yes, by current limitation permanently short-circuit proof |
12 V DC (reference voltage) >Proof against sustained short circuit |
Yes |
24 V DC >Output current |
0 - 0.35 A |
24 V DC >Effectiveness of current limitation |
> 0.4 A |
24 V DC >Overload proof |
Yes, by current limitation |
24 V DC >Proof against sustained short circuit |
Yes, hickup-mode |
Lamp load, cold, 24 V DC | 2 W |
Base load present | 1 W |
Behaviour on emergency-stop in 24 V circuit, disconnection with contactor (contactor load, no damage) | 6 W |
Indication of output voltage (LED, continuous green light = OK) | 24 V DC |
Rated operational current for specified heat dissipation [In] | 0 A |
Heat dissipation per pole, current-dependent [Pvid] | 0 W |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 1 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +55 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Input voltage at AC 50 Hz | 85 - 264 V |
Input voltage at AC 60 Hz | 85 - 264 V |
Input voltage at DC | 0 - 0 V |
Type of voltage (input voltage) | AC |
Max. input current AC 50 Hz | 0 A |
Max. input current AC 60 Hz | 0 A |
Max. input current DC | 0 A |
Type of output voltage | DC |
Output voltage at AC 50 Hz | 0 - 0 V |
Output voltage at AC 60 Hz | 0 - 0 V |
Output voltage at DC | 12 - 24 V |
Max. output current AC 50 Hz | 0 A |
Max. output current AC 60 Hz | 0 A |
Max. output current DC | 0.35 A |
Power output | 8.4 W |
Redundancy | No |
Suitable for safety functions | No |
Width | 32 mm |
Height | 90 mm |
Depth | 60 mm |
Product Standards | IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking |
UL File No. | E135462 |
UL Category Control No. | NRAQ |
CSA File No. | 012528 |
CSA Class No. | 2252-01 + 2258-02 |
North America Certification | UL listed, CSA certified |
Degree of Protection | IEC: IP20, UL/CSA Type: - |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.