Product range |
Control relays easyE4 |
Subrange |
easyE4 digital input/output enhancements |
Basic function |
easyE4 extensions |
Description |
Input/output extension for easyE4 control relay Expandable with the easyE4 series of digital input/output expansions with easy-E4-CONNECT1 connector (Item Y7-197225) Rated operating voltage 24V DC Digital inputs: 8 Digital outputs: 8 transistor Screw terminals |
Inputs expansion (number) |
|
Transistor |
digital: 8 |
Display |
|
Software |
8 |
Supply voltage |
|
For use with |
with diagnostic LED |
Standards |
EASYSOFT-SWLIC/easySoft 7 |
Approvals >Approvals |
24 V DC |
Approvals >certificate |
easyE4 |
Approvals >shipping classification |
|
Approvals |
EN 61000-6-2 EN 61000-6-3 IEC 60068-2-6 IEC 60068-2-27 IEC 60068-2-30 IEC 61131-2 EN 61010 EN 50178 |
Dimensions (W x H x D) |
cULus |
Weight |
CE |
Mounting |
DNV GL |
Connection type |
|
Screw terminals >Solid |
71.5 x 90 x 58 mm |
Screw terminals >flexible |
0.14 kg |
Screw terminals >Solid or flexible conductor, with ferrule |
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Screw terminals >Solid or stranded |
screw terminal |
Screw terminals >Standard screwdriver |
|
Screw terminals >Tightening torque |
0.2 - 4 mm2 |
Screw terminals >Stripping length |
0.2 - 2.5 mm2
|
Operating ambient temperature |
0,2 - 2,5 mm2
|
Condensation |
22 - 12 AWG |
Storage [ϑ] |
0.8 x 3.5 mm |
relative humidity |
0.5 - 0.7 Nm |
Air pressure (operation) |
6.5 mm |
Protection type (IEC/EN 60529, EN50178, VBG 4) |
|
Vibrations |
-25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms |
Take appropriate measures to prevent condensation |
Drop to IEC/EN 60068-2-31 [Drop height] |
-40 - +70 °C |
Free fall, packaged (IEC/EN 60068-2-32) |
in accordance with IEC 60068-2-30, IEC 60068-2-78 5 - 95 % |
Mounting position |
795 - 1080 hPa |
Overvoltage category/pollution degree |
|
Electrostatic discharge (ESD) >applied standard |
IP20 |
Electrostatic discharge (ESD) >Air discharge |
In accordance with IEC 60068-2-6 constant amplitude 0.15 mm: 10 - 57 constant acceleration 2 g: 57 - 150 Hz |
Electrostatic discharge (ESD) >Contact discharge |
18 Impacts |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 |
50 mm |
Radio interference suppression |
0.3 m |
Burst |
Vertical or horizontal |
power pulses (Surge) |
|
Immunity to line-conducted interference to (IEC/EN 61000-4-6) |
III/2 |
Clearance in air and creepage distances |
according to IEC EN 61000-4-2 |
Insulation resistance |
8 kV |
Rated operational voltage [Ue] |
6 kV |
Permissible range [Ue] |
0.8 - 1.0 GHz: 10 1.4 - 2 GHz: 3 2.0 - 2.7 GHz: 1 V/m |
Residual ripple |
EN 61000-6-3 Class B |
Protection against polarity reversal |
according to IEC/EN 61000-4-4 Supply cables: 2 Signal cables: 2 kV |
Input current |
according to IEC/EN 61000-4-5 0.5 kV (supply cables, symmetrical) 1 kV (supply cables, asymmetrical) |
Voltage dips |
10 V |
Fuse |
|
Power loss [P] |
nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Heat dissipation at 24 V DC |
in accordance with EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
Number |
|
Potential isolation |
24 DC (-15/+20%) V |
Rated operational voltage [Ue] |
20.4 - 28.8 V DC |
Input voltage |
≦ 5 % |
Input current at signal 1 |
yes |
Deceleration time |
max. 40 mA at Ue |
Cable length |
≤ 10 ms |
Number |
≧ 5A (T) A |
Rated operational voltage [Ue] |
Normally 1 W |
Permissible range [Ue] |
1 W |
Residual ripple |
|
Protection against polarity reversal |
8 |
Potential isolation |
from power supply: no between inputs: no from the outputs: no to expansion devices: yes to base unit: yes |
Rated operational current at signal „1” DC per channel [Ie] |
24 V DC |
Residual current on 0 signal per channel |
Signal 0: ≦ 5 (I1 - I8) Condition 1: ≧ 15 (I1 - I8) V DC |
Max. output voltage |
3.3 (I5 - I8) mA |
Short-circuit protection |
type 0.1 (0 -> 1) type 0.2 (1 -> 0) ms |
Short-circuit tripping current for Ra ≦ 10 mΩ |
100 (unshielded) m |
Total short-circuit current |
|
Thermal cutout |
8 |
Max. operating frequency with constant resistive load |
24 V DC |
Parallel connection of outputs >With resistive load, inductive load with external suppressor circuit, combination within a group |
20.4 - 28.8 V DC |
Parallel connection of outputs >Number of outputs [max.] |
5 % |
Parallel connection of outputs >Max. total current |
Yes (Caution: A short circuit will occur if a supply voltage of the wrong polarity is applied to the outputs.) |
Inductive load to EN 60947-5-1 >Without external suppressor circuit >DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Utilization factor |
from power supply: no between the inputs: no to the outputs: no to base unit: yes to expansion devices: yes |
Inductive load to EN 60947-5-1 >Without external suppressor circuit >DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Duty factor |
Max. 0.5 A |
Inductive load to EN 60947-5-1 >Without external suppressor circuit >T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Utilization factor |
< 0.005 mA |
Inductive load to EN 60947-5-1 >Without external suppressor circuit >T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Duty factor |
1 (at status 0 per channel) U = Ue - 1 V (signal 1 at Ie = 0.5 A) V |
Inductive load to EN 60947-5-1 >With external suppressor circuit >Utilization factor |
yes, electronic (Q1 - Q4, Q5 - Q8) |
Inductive load to EN 60947-5-1 >With external suppressor circuit >Duty factor |
0.7 ≦ Ie ≦ 1.7 per output depending on number of active channels and their load A |
Inductive load to EN 60947-5-1 >With external suppressor circuit >Max. switching frequency, max. duty factor |
13.6 A |
Power loss [P] |
Yes |
Static heat dissipation, non-current-dependent [Pvs] |
abhängig von der Zykluszeit des Basisgeräts und bei Erweiterungsgeräten auch von deren Übertragungszeit Operations/h |
Operating ambient temperature min. |
Group 1 Q1 to Q4 Group 2 Q5 to Q8 |
Operating ambient temperature max. |
8 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
4 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0.25 g |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
100 % DF |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0.25 g |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
100 % DF |
10.2 Strength of materials and parts >10.2.5 Lifting |
1 g |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
100 % DF |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Depending on the suppressor circuit Operations |
10.3 Degree of protection of ASSEMBLIES |
|
10.4 Clearances and creepage distances |
1 W |
10.5 Protection against electric shock |
|
10.6 Incorporation of switching devices and components |
1 W |
10.7 Internal electrical circuits and connections |
-25 °C |
10.8 Connections for external conductors |
+55 °C |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
|
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Meets the product standard´s requirements. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Supply voltage AC 50 Hz |
Does not apply, since the entire switchgear needs to be evaluated. |
Supply voltage AC 60 Hz |
Meets the product standard´s requirements. |
Supply voltage DC |
Meets the product standard´s requirements. |
Voltage type of supply voltage |
Meets the product standard´s requirements. |
Switching current |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of analogue inputs |
Does not apply, since the entire switchgear needs to be evaluated. |
Number of analogue outputs |
Is the panel builder´s responsibility. |
Number of digital inputs |
Is the panel builder´s responsibility. |
Number of digital outputs |
Is the panel builder´s responsibility. |
With relay output |
Is the panel builder´s responsibility. |
Number of HW-interfaces industrial Ethernet |
Is the panel builder´s responsibility. |
Number of interfaces PROFINET |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Number of HW-interfaces RS-232 |
Is the panel builder´s responsibility. |
Number of HW-interfaces RS-422 |
Is the panel builder´s responsibility. |
Number of HW-interfaces RS-485 |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of HW-interfaces serial TTY |
|
Number of HW-interfaces USB |
|
Number of HW-interfaces parallel |
0 - 0 V |
Number of HW-interfaces Wireless |
0 - 0 V |
Number of HW-interfaces other |
20.4 - 28.8 V |
With optical interface |
DC |
Supporting protocol for TCP/IP |
0.5 A |
Supporting protocol for PROFIBUS |
0 |
Supporting protocol for CAN |
0 |
Supporting protocol for INTERBUS |
8 |
Supporting protocol for ASI |
8 |
Supporting protocol for KNX |
No |
Supporting protocol for MODBUS |
0 |
Supporting protocol for Data-Highway |
0 |
Supporting protocol for DeviceNet |
0 |
Supporting protocol for SUCONET |
0 |
Supporting protocol for LON |
0 |
Supporting protocol for PROFINET IO |
0 |
Supporting protocol for PROFINET CBA |
0 |
Supporting protocol for SERCOS |
0 |
Supporting protocol for Foundation Fieldbus |
0 |
Supporting protocol for EtherNet/IP |
2 |
Supporting protocol for AS-Interface Safety at Work |
No |
Supporting protocol for DeviceNet Safety |
No |
Supporting protocol for INTERBUS-Safety |
No |
Supporting protocol for PROFIsafe |
No |
Supporting protocol for SafetyBUS p |
No |
Supporting protocol for other bus systems |
No |
Radio standard Bluetooth |
No |
Radio standard WLAN 802.11 |
No |
Radio standard GPRS |
No |
Radio standard GSM |
No |
Radio standard UMTS |
No |
IO link master |
No |
Redundancy |
No |
With display |
No |
Degree of protection (IP) |
No |
Basic device |
No |
Expandable |
No |
Expansion device |
No |
With timer |
No |
Rail mounting possible |
No |
Wall mounting/direct mounting |
No |
Front build in possible |
No |
Rack-assembly possible |
No |
Suitable for safety functions |
No |
Category according to EN 954-1 |
No |
SIL according to IEC 61508 |
No |
Performance level acc. EN ISO 13849-1 |
No |
Appendant operation agent (Ex ia) |
No |
Appendant operation agent (Ex ib) |
No |
Explosion safety category for gas |
No |
Explosion safety category for dust |
No |
Width |
IP20 |
Height |
No |
Depth |
Yes |
UL File No. |
Yes |
UL Category Control No. |
No |
North America Certification |
Yes |
Degree of Protection |
Yes |