Soft starter, 41 A, 200 - 480 V AC, 24 V DC, Frame size: FS3, Communication Interfaces: SmartWire-DTSoft starter, Product range: SmartWire-DT slave, Description: With internal bypass contacts, Function: Soft starters for three-phase loads, Mains supply voltage (50/60 Hz): ULN= 200 - 480 V AC, Supply voltage: Us= 24 V DC, Control voltage: UC= 24 V DC, Assigned motor rating (Standard connection, In-Line) at 400 V, 50 Hz: P= 22 kW, at 460 V, 60 Hz: P= 30 HP, Rated operational current AC-53: Ie= 41 A, Rated operational voltage: Ue= 200 V, 230 V, 400 V, 480 V, Connection to SmartWire-DT: yes, Frame size: FS3, Standards: IEC/EN 60947-4-2, UL 508, CSA22.2-14
Soft starter, 41 A, 200 - 480 V AC, 24 V DC, Frame size: FS3, Communication Interfaces: SmartWire-DT
Soft starter, Product range: SmartWire-DT slave, Description: With internal bypass contacts, Function: Soft starters for three-phase loads, Mains supply voltage (50/60 Hz): ULN= 200 - 480 V AC, Supply voltage: Us= 24 V DC, Control voltage: UC= 24 V DC, Assigned motor rating (Standard connection, In-Line) at 400 V, 50 Hz: P= 22 kW, at 460 V, 60 Hz: P= 30 HP, Rated operational current AC-53: Ie= 41 A, Rated operational voltage: Ue= 200 V, 230 V, 400 V, 480 V, Connection to SmartWire-DT: yes, Frame size: FS3, Standards: IEC/EN 60947-4-2, UL 508, CSA22.2-14
Product range | SmartWire-DT slave |
Subrange | SmartWire-DT Soft starters |
Description | With internal bypass contacts |
Function | Soft starters for three-phase loads |
Mains supply voltage (50/60 Hz) [ULN] | 200 - 480 V AC |
Supply voltage [Us] | 24 V DC |
Control voltage [UC] | 24 V DC |
at 400 V, 50 Hz [P] | 22 kW |
at 460 V, 60 Hz [P] | 30 HP |
AC-53 [Ie] | 41 A |
Rated operational voltage [Ue] | 200 V 230 V 400 V 480 V |
Connection to SmartWire-DT | yes |
Frame size | FS3 |
Standards | IEC/EN 60947-4-2 UL 508 CSA22.2-14 |
Approvals | CE |
Approvals | UL CSA C-Tick UkrSEPRO |
Climatic proofing | Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-10 |
Ambient temperature >Operation [ϑ] |
-5 - +40 up to 60 at 2% derating per Kelvin temperature rise °C |
Ambient temperature >Storage [ϑ] |
-25 - +60 °C |
Altitude | 0 - 1000 m, above that 1 % derating per 100 m , up to 2000 m m |
Mounting position | Vertical |
Degree of protection >Degree of Protection |
IP20 (terminals IP00) |
Degree of protection >Integrated |
Protection type IP40 can be achieved on all sides with covers from the NZM range. |
Protection against direct contact | Finger- and back-of-hand proof |
Overvoltage category/pollution degree | II/2 |
Shock resistance | 8 g/11 ms |
Vibration resistance to EN 60721-3-2 | 2M2 |
Radio interference level (IEC/EN 55011) | B |
Static heat dissipation, non-current-dependent [Pvs] | 7 W |
Weight | 1.8 kg |
Rated operating voltage [Ue] | 200 - 480 V AC |
Supply frequency [fLN] | 50/60 Hz |
Rated operational current [Ie
] >AC-53 [Ie] |
41 A |
Assigned motor rating (Standard connection, In-Line) >at 230 V, 50 Hz [P] |
11 kW |
Assigned motor rating (Standard connection, In-Line) >at 400 V, 50 Hz [P] |
22 kW |
Assigned motor rating (Standard connection, In-Line) >at 200 V, 60 Hz [P] |
10 HP |
Assigned motor rating (Standard connection, In-Line) >at 230 V, 60 Hz [P] |
15 HP |
Assigned motor rating (Standard connection, In-Line) >at 460 V, 60 Hz [P] |
30 HP |
Overload cycle to IEC/EN 60947-4-2 >AC-53a |
41 A: AC-53a: 3 - 5: 75 - 10 |
Overload cycle to IEC/EN 60947-4-2 >Internal bypass contacts |
✓ |
Short-circuit rating >Type “1” coordination |
NZMN1-M50/PKZM4-49 |
Short-circuit rating >Type „2“ coordination (additional with the fuses for coordination type „1“) |
3 x 170M3013 |
Fuse base (number x part no.) | 3 x 170H3004 |
Cable lengths >Solid |
1 x (25 - 70) 2 x (6 - 25) mm2 |
Cable lengths >Stranded |
1 x (25 - 70) 2 x (6 - 25) mm2 |
Cable lengths >Solid or stranded |
1 x (12 - 2/0) AWG |
Cable lengths >Copper band |
2 x 9 x 0.89 x 9 x 0.8 MM |
Cable lengths >Tightening torque |
6 (≤ 10 mm²); 9 (> 10 mm²) Nm |
Cable lengths >Screwdriver (PZ: Pozidriv) |
PZ2; 1 x 6 mm mm |
Control cables >Solid |
1 x (0.5 - 2.5) 2 x (0.5 - 1.0) mm2 |
Control cables >Flexible with ferrule |
1 x (0.5 - 1.5) 2 x (0.5 - 0.75) mm2 |
Control cables >Stranded |
1 x (0.5 - 1.5) 2 x (0.5 - 1.0) mm2 |
Control cables >Solid or stranded |
1 x (21 - 14) 2 x (21 - 18) AWG |
Control cables >Tightening torque |
0.4 Nm |
Control cables >Screwdriver |
0,6 x 3,5 mm |
Digital inputs >Control voltage >DC-operated |
24 V DC +10 %/- 15 % oder über SWD V DC |
Digital inputs >Current consumption 24 V >External 24 V |
1.6 mA |
Digital inputs >Pick-up voltage >DC-operated |
17.3 - 27 V DC |
Digital inputs >Drop-out voltage [x Us ] >DC operated |
0 - 3 V DC |
Digital inputs >Pick-up time >DC operated |
250 ms |
Digital inputs >Drop-out time >DC operated |
350 ms |
Regulator supply >Voltage [Us] |
24 V DC +10 %/- 15 % V |
Regulator supply >Current consumption [Ie] |
50 mA |
Regulator supply >Current consumption at peak performance (close bypass) at 24 V DC [IPeak] |
0,6/50 A/ms |
Regulator supply >Notes |
External supply voltage |
Relay outputs >Number |
2 (TOR, Ready) |
Relay outputs >Voltage range |
250 V AC |
Relay outputs >AC-11 current range |
1 A, AC-11 A |
Ramp times >Acceleration |
1 - 30 s |
Ramp times >Deceleration |
0 - 30 s |
Start voltage (= turn-off voltage) | 30100 % |
Start pedestal | 30 - 100 % |
Current limitation | (0 - 8) x Ie |
Fields of application >Fields of application |
Soft starting of three-phase asynchronous motors |
Fields of application >1-phase motors |
● |
Fields of application >3-phase motors |
✓ |
Fast switching (semiconductor contactor) | - (minimum ramp time 1s) |
Soft start function | ✓ |
Reversing starter | External solution required |
Suppression of closing transients | ✓ |
Current limitation | ✓, with PKE |
Fault memory | 8 Faults |
Suppression of DC components for motors | ✓ |
Potential isolation between power and control sections | ✓ |
Communication Interfaces | SmartWire-DT |
Rated operational current for specified heat dissipation [In] | Rated impulse withstand voltage:
|
Heat dissipation per pole, current-dependent [Pvid] | 41 A |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 7 W |
Heat dissipation capacity [Pdiss] | 7 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | -5 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+40 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated operation current Ie at 40 °C Tu | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated operating voltage Ue | 41 A |
Rated power three-phase motor, inline, at 230 V | 230 - 460 V |
Rated power three-phase motor, inline, at 400 V | 11 kW |
Rated power three-phase motor, inside delta, at 230 V | 22 kW |
Rated power three-phase motor, inside delta, at 400 V | 0 kW |
Function | 0 kW |
Internal bypass | Single direction |
With display | Yes |
Torque control | No |
Rated surrounding temperature without derating | No |
Rated control supply voltage Us at AC 50HZ | 40 °C |
Rated control supply voltage Us at AC 60HZ | 0 - 0 V |
Rated control supply voltage Us at DC | 0 - 0 V |
Voltage type for actuating | 24 - 24 V |
Integrated motor overload protection | DC |
Release class | No |
Degree of protection (IP) | Other |
Degree of protection (NEMA) | IP20 |
Product Standards | 1 |
Specially designed for North America | IEC/EN 60947-4-2; GB 14048.6; UL 508; CSA-C22.2 No 0-M91; CSA-C22.2 No 14-05 CE marking |
Suitable for | No |
Current Limiting Circuit-Breaker | Branch circuits |
Max. Voltage Rating | No |
Degree of Protection | 480 V |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.