Power supply unit, 1p, 100VA, prim 230VAC, sec. 24VAC, 24 V DC, 10 V DCUniversal power supply unit single-phase, safety transformer to IEC/EN 61558-2-2, 2-6, VDE 0570 Part 2-2, 2-6. rated power 100VA, one fuse per output voltage, a changeover contact for monitoring and annunciation, rated input voltage 230V +- 5%, rated output voltage / current: 24V AC / 4.2A, 10V DC / 1A, 24V DC / 3A
Power supply unit, 1p, 100VA, prim 230VAC, sec. 24VAC, 24 V DC, 10 V DC
Universal power supply unit single-phase, safety transformer to IEC/EN 61558-2-2, 2-6, VDE 0570 Part 2-2, 2-6. rated power 100VA, one fuse per output voltage, a changeover contact for monitoring and annunciation, rated input voltage 230V +- 5%, rated output voltage / current: 24V AC / 4.2A, 10V DC / 1A, 24V DC / 3A
Product range | Universal power supply unit AING |
Basic function | Single-phase power supply |
Rated input voltage | Every output voltage a fuse, an LED and a changeover contact for monitoring and annunciation Non-standard voltages on request |
Rated output voltage | 230± 5 % V |
Rated power | 24 AC, 10 DC, 24 DC V |
Max. output current | 0.1 kVA |
Cu factor | 4.2 1 3 A |
Notes | 3,40 kg |
Standards >Built and tested to |
Signal contacts Switching voltage max. 250 V AC/110 V DC max. 1 A Switching duty 62 VA/30 W LED indication
Size/part no. FK2 fuses are used. |
Standards >Suitable for use to |
Safety transformer to IEC/EN 61558-2-2/2-6 VDE 0570 part 2-2/2-6 |
Ambient temperature | IEC/EN 60204-1 VDE 0113 |
Terminations | -25 - 40 |
Insulation class | ● |
Rated frequency | B |
Primary tapping | 50 - 60 Hz |
Degree of Protection | ± 5 % |
Separate windings | IP20 |
Fully vacuum-impregnated | ● |
Reinforced insulation | ● |
Rated duty factor | ● |
Rated operational current for specified heat dissipation [In] | 100 % DF |
Heat dissipation per pole, current-dependent [Pvid] | 0 A |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 50 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | -25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+40 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Input voltage at AC 50 Hz | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Input voltage at AC 60 Hz | 230 - 230 V |
Input voltage at DC | 230 - 230 V |
Type of voltage (input voltage) | 0 - 0 V |
Max. input current AC 50 Hz | AC |
Max. input current AC 60 Hz | 0.44 A |
Max. input current DC | 0.44 A |
Type of output voltage | 0 A |
Output voltage at AC 50 Hz | AC/DC |
Output voltage at AC 60 Hz | 24 - 24 V |
Output voltage at DC | 24 - 24 V |
Max. output current AC 50 Hz | 24 - 24 V |
Max. output current AC 60 Hz | 4.2 A |
Max. output current DC | 4.2 A |
Power output | 3 A |
Redundancy | 100 W |
Suitable for safety functions | No |
Width | Yes |
Height | 110 mm |
Depth | 155 mm |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.