Arc Fault Detection Device, 2 poles, C20A-OL, 30mA, type ACArc-fault detection device with residual current operated circuit-breaker with overcurrent protection, conforms to IEC/EN 62606, reliably detects arc faults, residual current circuit-breaker part is mains voltage-independent, optionally pulse-current sensitive, delayed or non-delayed, red/green contact position indicator, trip indication with LED; guide for secure terminal connection, three-position DIN rail clip - makes removal from an existing busbar system possible, comprehensive range of accessories that can be retrofitted, rated fault currents: 10 mA or 30 mA, rated operational currents of up to 40 A, trip characteristics B,C, rated making and breaking capacity of up to 10 kA, suitable for outdoor use (building and outdoor distribution boards) at temperatures as low as -25 °C
Arc Fault Detection Device, 2 poles, C20A-OL, 30mA, type AC
Arc-fault detection device with residual current operated circuit-breaker with overcurrent protection, conforms to IEC/EN 62606, reliably detects arc faults, residual current circuit-breaker part is mains voltage-independent, optionally pulse-current sensitive, delayed or non-delayed, red/green contact position indicator, trip indication with LED; guide for secure terminal connection, three-position DIN rail clip - makes removal from an existing busbar system possible, comprehensive range of accessories that can be retrofitted, rated fault currents: 10 mA or 30 mA, rated operational currents of up to 40 A, trip characteristics B,C, rated making and breaking capacity of up to 10 kA, suitable for outdoor use (building and outdoor distribution boards) at temperatures as low as -25 °C
Basic function | Arc fault detection device |
Number of poles | 2 pole |
Tripping characteristic | C |
Application | Switchgear for residential and commercial applications |
Rated current [In] | 20 A |
Rated switching capacity according to IEC/EN 60898-1 [Icn] | 10 kA |
Rated switching capacity according to IEC/EN 61009 | 10 kA |
Rated short-circuit strength [Icn] | 10 kA |
Rated fault current [IΔN] | 0.03 A |
Type | Type AC |
Tripping | non-delayed s… |
Busbar type | ZV-SS |
Product range | AFDD |
Sensitivity | AC current sensitive |
Impulse withstand current | Partly surge-proof 250 A |
Types conform to | IEC/EN 62606 IEC/EN 61009 |
Current test marks | As per inscription |
Rated switching capacity according to IEC/EN 60898-1 [Icn] | 10 kA |
Limit values of the operating voltage >Test circuit |
170 - 264 V AC |
Sensitivity | AC current sensitive |
Rated short-circuit strength [Icn] | 10 kA |
lifespan >Electrical [Operations] |
≧ 4000 |
lifespan >Mechanical [Operations] |
≧ 20000 |
Standard front dimension | 45 mm |
Device height | 80 mm |
Built-in width | 54 (3TE) mm |
Mounting | Tristable slide catch enables removal from existing combination. |
Degree of Protection | IP20 switches IP40 enclosed |
Terminals top and bottom | Twin-purpose terminals |
Terminal protection | Busbar tag shroud as per VBG4, ÖVE-EN 6 |
Thickness of busbar material | 0.8 - 2 mm |
Admissible ambient temperature range | -25 - +40 °C |
Permissible storage and transport temperatures | -35 - +60 °C |
Climatic proofing | according to IEC/EN 61009 |
Contact position indicator | red / green |
Rated operational current for specified heat dissipation [In] | 20 A |
Equipment heat dissipation, current-dependent [Pvid] | 8 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +40 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of poles | 2 |
Rated voltage | 230 V |
Rated current | 20 A |
Rated fault current | 0.03 A |
Leakage current type | AC |
Current limiting class | 3 |
Rated short-circuit breaking capacity acc. EN 61009 | 10 kA |
Rated short-circuit breaking capacity IEC 60947-2 | 0 kA |
Frequency | 50 Hz |
Release characteristic | C |
Concurrently switching N-neutral | No |
Over voltage category | 3 |
Pollution degree | 2 |
Width in number of modular spacings | 3 |
Built-in depth | 67 mm |
Additional equipment attached at delivery | Fire protection switch |
Rated switch current auxiliary device | 0 A |
Rated voltage auxiliary device | 230 V |
Control voltage type auxiliary equipment | AC |
Degree of protection (IP) | IP20 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.