alt
alt

Sick-System S700
System S700

Gas AnalyzersS700, System S700Measured values: Ar, CBrF3, CClF3, CCl2F2, CCl3F, CHClF2, CHCl3, CH2Cl2, CH2O, CH3Cl, CH3OH, (CH3)2O, CH4, CO, CO2, CS2, C2Cl2F4, C2Cl3F3, C2Cl4, C2HCl3, C2H2, C2H2Cl2, C2H2F4, C2H3Cl3, C2H4, C2H4Cl2, C2H5OH, C2H6, C3H4, C3H6, C3H7OH, C3H8, C3H8O2, C4H6, C4H8, C4H10, C4H8O, C4H9OH, C5H12, C6H10O, C6H12, C6H14, C7H16, C7H8, C8H10, He, H2, H2O, NH3, NO, N2O, O2, SF6, SO2

Gas Analyzers
S700, System S700
Measured values: Ar, CBrF3, CClF3, CCl2F2, CCl3F, CHClF2, CHCl3, CH2Cl2, CH2O, CH3Cl, CH3OH, (CH3)2O, CH4, CO, CO2, CS2, C2Cl2F4, C2Cl3F3, C2Cl4, C2HCl3, C2H2, C2H2Cl2, C2H2F4, C2H3Cl3, C2H4, C2H4Cl2, C2H5OH, C2H6, C3H4, C3H6, C3H7OH, C3H8, C3H8O2, C4H6, C4H8, C4H10, C4H8O, C4H9OH, C5H12, C6H10O, C6H12, C6H14, C7H16, C7H8, C8H10, He, H2, H2O, NH3, NO, N2O, O2, SF6, SO2

Description19″ rack enclosure with 3 rack units, for integration in cabinets
Measured valuesAr, CBrF3, CClF3, CCl2F2, CCl3F, CHClF2, CHCl3, CH2Cl2, CH2O, CH3Cl, CH3OH, (CH3)2O, CH4, CO, CO2, CS2, C2Cl2F4, C2Cl3F3, C2Cl4, C2HCl3, C2H2, C2H2Cl2, C2H2F4, C2H3Cl3, C2H4, C2H4Cl2, C2H5OH, C2H6, C3H4, C3H6, C3H7OH, C3H8, C3H8O2, C4H6, C4H8, C4H10, C4H8O, C4H9OH, C5H12, C6H10O, C6H12, C6H14, C7H16, C7H8, C8H10, He, H2, H2O, NH3, NO, N2O, O2, SF6, SO2
Performance-tested measurandsCO, NO, O2, SO2
Maximum number of measurands4
Measurement principlesNDIR spectroscopy, electrochemical cell
Gas flow rate
No integrated sample gas pump5 l/h ... 100 l/h
With integrated sample gas pump30 l/h ... 60 l/h
Response time (t90)

MULTOR analyzer module: ≤ 25 s
At 60 l/h, depending on cuvette length, gas flow and number of measuring components

OXOR-E analyzer module: 20 s
Typical at 60 l/h, depending on gas flow

Sensitivity drift
MULTOR analyzer module≤ 1 %: of measuring range full scale per week
OXOR-E analyzer module≤ 1 %: of measuring range full scale per week
Zero point drift
MULTOR analyzer module≤ 1 %: of smallest measuring range per week
OXOR-E analyzer module≤ 2 %: of smallest measuring range per month
Sample gas temperature
Analyzer inlet0 °C ... +45 °C
Temperature at analyzer inlet
Process pressure
Hosed internal gas paths–20 kPa ... 30 kPa
Piped internal gas paths–20 kPa ... 100 kPa
With “OXOR-E” analyzer module–20 kPa ... 30 kPa
S720 Ex/S721 Ex–20 kPa ... 10 kPa
Process gas humidity
Non-condensing
Dust load
Free of dust and aerosols
Ambient temperature
+5 °C ... +45 °C
Storage temperature
–20 °C ... +70 °C
Ambient pressure
700 hPa ... 1,200 hPa
Geographical altitude≤ 2,000 m (above mean sea level)
Ambient humidity
≤ 95 %
Relative humidity; non-condensing
Conformities

Industrial Emissions Directive (IED)

CCEP

U.S. EPA conform

China´s EPA compliant

Electrical safetyCE, CSA (option)
Enclosure rating
IP20
Analog outputs4 outputs:
0/4 ... 20 mA, 500 Ω
0 ... 10 V
Electrically isolated
Analog inputs

2 inputs:
0/2/4 ... 20 mA

Option:
0 ... 10 V DC

Digital outputs

8 relay contacts:
Three relay outputs preset for failure, service and maintenance

8 Open collector outputs:
Freely adjustable

Digital inputs8 optical coupler inputs:
Electrically isolated; freely programmable

Modbus

✔ , ✔
RemarkOptional
Type of fieldbus integrationRTU RS-232
RS-485
Ethernet
RemarkOptional
Indication
LC display
OperationMenu-driven operation via LC-display and membrane keyboard
Menu languagesGerman, English, French, Italian, Dutch, Polish, Swedish, Spanish
Dimensions (W x H x D)
483 mm x 132.5 mm x 390 mm (for details see dimensional drawings)
Weight
10 kg ... 20 kg
Depending on configuration
Energy supply
Voltage100 V AC, - 15 % / + 10 %
115 V AC, - 15 % / + 10 %
230 V AC, - 15 % / + 10 %
Frequency48 ... 62 Hz
Power consumption≤ 150 VA
Depending on system configuration
Sample gas connections
PVDF bulkhead fitting
Corrective functions

Automatic testing and adjustment with test gases

Manual adjustment with test gases

Integrated components

MULTOR analyzer module

OXOR-E analyzer module

PVDF bulkhead fitting

Options

Integrated sample gas pump (only with hosed gas lines)

Tubed gas lines

Up tu three separate gas lines

Flow sensor

Humidity sensor

Barometric pressure correction

Sample gas pressure correction

Sample point switching (max. 8 sample points)

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

Contrinex-YXL-0001-000
Contrinex
Contrinex-IDLR-C23PP-NMS-A0
Contrinex
Contrinex-IDLR-M18MP-NMS-A0
Contrinex
Sick-PBS-CB016SN1SS0BMA0Z
Sick
Sick-PBS-RB6X0SGESS0CMA0Z
Sick
Sick-PBS-CK4X0SG1SSNGMA0Z
Sick
Sick-PBS-RB040SF2FSNNMA0Z
Sick
Sick-PBS-CB1X0SG2SS0BMA0Z
Sick
Sick-PBS-RB4X0SGHSS0AMA0Z
Sick
Sick-PBS-RB400SG2SS0CMA0Z
Sick
Sick-SRM50-HGV0-S23
Sick
Sick-PBS-RB4X0SG1SSNE5A0Z
Sick