| Measured values | CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2, NOx, C3H8, C2H6 |
| Performance-tested measurands | CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2 |
| Measurement principles | FTIR spectroscopy, flame ionisation detection, Zirconium dioxide sensor |
|
| Measuring ranges | | | CH4 | 0 ... 70 ppm / 0 ... 210 ppm | | SO2 | 0 ... 25 ppm / 0 ... 525 ppm | | NOx | 0 ... 100 ppm / 0 ... 1,000 ppm | | C3H8 | 0 ... 25 ppm | | CO | 0 ... 60 ppm / 0 ... 1,200 ppm | | CO2 | 0 ... 25 Vol.-% | | Corg | 0 ... 7.5 ppm / 0 ... 75 ppm | | HCl | 0 ... 10 ppm / 0 ... 100 ppm | | HF | 0 ... 3 ppm / 0 ... 10 ppm | | H2O | 0 ... 40 Vol.-% | | NH3 | 0 ... 13 ppm / 0 ... 65 ppm | | NO | 0 ... 150 ppm / 0 ... 1,500 ppm | | NO2 | 0 ... 25 ppm / 0 ... 250 ppm | | N2O | 0 ... 25 ppm / 0 ... 250 ppm | | O2 | 0 ... 21 Vol.-% | | C2H6 | 0 ... 40 ppm | | Other measuring ranges and components on request |
|
| Certified measuring ranges | | | CH4 | 0 ... 50 mg/m³ / 0 ... 150 mg/m³ | | CO | 0 ... 75 mg/m³ / 0 ... 300 mg/m³ / 0 ... 1,500 mg/m³ | | CO2 | 0 ... 25 Vol.-% | | Corg | 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 150 mg/m³ / 0 ... 500 mg/m³ | | HCl | 0 ... 15 mg/m³ / 0 ... 90 mg/m³ / 0 ... 150 mg/m³ | | HF | 0 ... 3 mg/m³ / 0 ... 10 mg/m³ | | H2O | 0 ... 40 Vol.-% | | NH3 | 0 ... 10 mg/m³ / 0 ... 50 mg/m³ | | NO | 0 ... 200 mg/m³ / 0 ... 400 mg/m³ / 0 ... 2,000 mg/m³ | | NO2 | 0 ... 100 mg/m³ / 0 ... 500 mg/m³ | | N2O | 0 ... 50 mg/m³ / 0 ... 500 mg/m³ | | O2 | 0 ... 21 Vol.-% | | SO2 | 0 ... 75 mg/m³ / 0 ... 300 mg/m³ / 0 ... 1,500 mg/m³ |
|
| Response time (t90) | ≤ 200 s FID: ≤ 45 s |
| Sensitivity drift | | | < 3 %: of the measuring range full scale value per maintenance interval | | FID | < 2 %: of measuring range full scale per week |
|
| Zero point drift | | | < 3 %: of the measuring range full scale value per maintenance interval | | FID | < 2 %: of measuring range full scale per week |
|
| Detection limit | | | < 2 %: of measuring range full scale |
|
| Process temperature | | | ≤ +1,300 °C |
|
| Sample gas temperature | | | ≤ +220 °C |
|
| Process pressure | | | 900 hPa ... 1,100 hPa |
|
| Ambient temperature | | | +5 °C ... +35 °C | | With cooling device | +5 °C ... +50 °C |
|
| Storage temperature | | | –20 °C ... +60 °C |
|
| Ambient pressure | | | 900 hPa ... 1,100 hPa |
|
| Ambient humidity | | | ≤ 80 % Non-condensing |
|
| Conformities | Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS |
| Electrical safety | CE |
| Enclosure rating | | | IP43 | | Optional | IP54 |
|
| Analog outputs | 0/4 ... 22 mA, 500 Ω Number depends on system configuration; electrically isolated; max. 32 outputs |
| Analog inputs | 0/4 ... 22 mA, 100 Ω Number depends on system configuration; electrically isolated; max. 32 inputs |
| Digital outputs | 48 V AC, 0.5 A, 35 W / 48 V DC, 0.5 A, 24 W Number depends on system configuration; electrically isolated; max. 64 outputs |
| Digital inputs | 3.9 V, 4.5 mA, 0.55 W Number depends on system configuration; max. 64 inputs |
Modbus | ✔ , ✔ | | Type of fieldbus integration | TCP | | RTU RS-485 |
|
|
| Ethernet | ✔ | | Function | Connection to SOPAS ET software or OPC server |
|
| Indication | | | LC display | | Status LEDs: “Power,” “Failure,” and “Maintenance request” |
|
| Input | Touchscreen |
| Operation | Via LC-display or software SOPAS ET Several operating levels, password-protected |
| Dimensions (W x H x D) | | | Analyzer cabinet | 806 mm x 2,165 mm x 605 mm (for details see dimensional drawings) | | With cooling device | 1,096 mm x 2,165 mm x 605 mm |
|
|
| Energy supply | | | Depending on device version | | Power consumption | Analyzer cabinet: ≤ 1,000 VA Without cooling device | | Sample gas line, heated: ≤ 95 VA | | Gas sampling unit: ≤ 450 VA | | Heated gas sampling pipe: ≤ 450 VA |
|
| Auxiliaries | | | Zero gas (FTIR/FID) | ≤ 300 l/h ... ≤ 350 l/h Instrument air; 3±0.2 bar; particle size max. 1 µm; oil content max. 0.1 mg/m³; pressure dew point max. –30 °C | | Zero gas (O2) | ≤ 350 l/h O2 in N2: 1 ... 4 Vol.-%; accuracy ±2%; 3 ±0.2 bar | | Reference gas (FTIR) | ≤ 350 l/h Measuring component in N2; 70% of measuring range full scale; 3 ±0.2 bar | | Reference gas (O2) | ≤ 350 l/h Ambient air | | Reference gas (FID) | ≤ 450 l/h Propane in synthetic air: 75% of measuring range full scale value | | Instrument air | ≤ 2,000 l/h Instrument air: 5 ... 7 bar; particle size max. 1 µm; oil content max. 0.1 mg/m³; pressure dew point max. –30 °C | | Fuel gas | ≤ 4.8 l/h Hydrogen: 5.0 or higher; 3 ±0.2 bar | | Combustion air | ≤ 30 l/h Instrument air; 3±0.2 bar; particle size max. 1 µm; oil content max. 0.1 mg/m³; pressure dew point max. –30 °C |
|
| Sample gas connections | | | Sample gas inlet | DN 4/6 | | Exhaust gas outlet | DN 8/10 |
|
| Auxiliary gas connections | | | Test gas | DN 4/6 | | Fuel gas | DN 4/6 | | Instrument air | DN 6/8 |
|
| Corrective functions | Internal adjustment unit (option) |
| Test functions | Internal zero point check |
| Options | Integrated total hydrocarbon analyzer |