Schmersal : SSW303HV-2S-103037586
SSW303HV-2S
SSW303HV-2S-103037586
Standstill detection time 2sFail-safe standstill monitors3 safety contacts3 Signalling contactsSensor-free detection of standstill by monitoring e.m.f.Direct connection to three-phase motorsMotor voltage range 0 ... 690 V
- Standstill detection time 2s
- Fail-safe standstill monitors
- 3 safety contacts
- 3 Signalling contacts
- Sensor-free detection of standstill by monitoring e.m.f.
- Direct connection to three-phase motors
- Motor voltage range 0 ... 690 V
Ordering data
| Product type description | SSW303HV-2S |
| Article number (order number) | 103037586 |
| EAN (European Article Number) | 4030661546438 |
| eCl@ss number, version 12.0 | 27-37-18-19 |
| eCl@ss number, version 11.0 | 27-37-18-19 |
| eCl@ss number, version 9.0 | 27-37-18-19 |
| ETIM number, version 7.0 | EC001449 |
| ETIM number, version 6.0 | EC001449 |
Approvals - Standards
| TÜV cULus CCC |
General data
| Standards | EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
| Climatic stress | EN 60068-2-78 |
| Housing material | Glass-fibre, reinforced thermoplastic |
| Gross weight | 500 g |
General data - Features
| Wire breakage detection | Yes |
| Cross-circuit detection | Yes |
| Feedback circuit | Yes |
| Automatic reset function | Yes |
| Earth connection detection | Yes |
| Integral system diagnostics, status | Yes |
| Number of auxiliary contacts | 3 |
| Number of LEDs | 5 |
| Number of safety contacts | 3 |
| Safety classification |
| Standards | EN ISO 13849-1 EN IEC 61508 |
| Mission time | 20 Year(s) |
| Common Cause Failure (CCF), minimum | 65 |
| Stop-Category | 0 |
| Safety classification - Relay outputs |
| Performance Level, stop 0, up to | e |
| Category, Stop 0 | 4 |
| Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 % |
| PFH value, Stop 0 | 2.00 x 10⁻⁸ /h |
| Safety Integrity Level (SIL), Stop 0, suitable for applications in | 3 |
Mechanical data
| Mechanical life, minimum | 10,000,000 Operations |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
| Terminal designations | IEC/EN 60947-1 |
| Termination | rigid or flexible Screw connection, plug-in |
| Cable section, minimum | 0.25 mm² |
| Cable section, maximum | 2.5 mm² |
| Tightening torque of Clips | 0.6 Nm |
Mechanical data - Dimensions
| Width | 45 mm |
| Height | 120 mm |
| Depth | 121 mm |
Ambient conditions
| Degree of protection of the enclosure | IP40 |
| Degree of protection of the mounting space | IP54 |
| Degree of protection of clips or terminals | IP20 |
| Ambient temperature | -25 ... +55 °C |
| Storage and transport temperature | -40 ... +85 °C |
| Resistance to vibrations | 5 ... 9 Hz, Amplitude 3.5 mm |
| Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation values
| Rated impulse withstand voltage Uimp | 8 kV |
| Rated impulse withstand voltage Uimp, relay output | 6 kV |
| Degree of pollution | 2 |
Electrical data
| Operating voltage | 24 VDC -10 % / +20 % |
| Ripple voltage | 10 % |
| Type of voltage range | AC |
| Rated operating voltage | 24 VDC |
| Rated operating voltage | 24 ... 230 VAC |
| Rated AC voltage for controls, 50 Hz, minimum | 21.6 VAC |
| Rated control voltage at AC 50 Hz, maximum | 253 VAC |
| Rated AC voltage for controls, 60 Hz, minimum | 21.6 VAC |
| Rated control voltage at AC 60 Hz, maximum | 253 VAC |
| Electrical power consumption, maximum | 4 W |
| Electrical power consumption, maximum | 8.5 VA |
| Contact resistance, maximum | 0.1 Ω |
| Note (Contact resistance) | in new state |
| Drop-out delay in case of "emergency stop", maximum | 15 ms |
| Pull-in delay at automatic start (after detecting standstill), approx. | 2,000 ms |
| Material of the contacts, electrical | AgSn0 + Au, self-cleaning, positive drive |
Electrical data - Safe relay outputs
| Voltage, Utilisation category AC-15 | 230 VAC |
| Current, Utilisation category AC-15 | 6 A |
| Voltage, Utilisation category DC-13 | 24 VDC |
| Current, Utilisation category DC-13 | 6 A |
| Switching capacity, minimum | 10 VDC |
| Switching capacity, minimum | 10 mA |
| Switching capacity, maximum | 250 VAC |
| Switching capacity, maximum | 6 A |
Electrical data - Digital inputs
| Conduction resistance, maximum | 40 Ω |
Electrical data - Relay outputs (auxiliary contacts)
| Switching capacity, maximum | 24 VDC |
| Switching capacity, maximum | 2 A |
Electrical data - Electromagnetic compatibility (EMC)
| EMC rating | EMC-Directive |
Status indication
| Indicated operating states | OUT, green: release switching condition UB: Supply voltage on ERR: Error functional defect |
Other data
| Note (applications) | safe standstill monitoring |
Note
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.