Suitable for the signal processing of outputs with contact sensorsPossibility to connect a non-contact end switch or speed reduction switch2 safety contacts, switch-off level 1;2 safety contacts, switch-off level 22 Signalling outputs
Replacement article number | 101178532 |
Product type description | SRB402NE 230V |
Article number (order number) | 101178397 |
EAN (European Article Number) | 4250116202423 |
eCl@ss number, version 12.0 | 27-37-18-19 |
eCl@ss number, version 11.0 | 27-37-18-19 |
eCl@ss number, version 9.0 | 27-37-18-19 |
ETIM number, version 7.0 | EC001449 |
ETIM number, version 6.0 | EC001449 |
Standards | EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress | EN 60068-2-78 |
Housing material | Glass-fibre reinforced thermoplastic, ventilated |
Gross weight | 550 g |
Wire breakage detection | Yes |
Cross-circuit detection | Yes |
Removable Terminals | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Earth connection detection | Yes |
Integral system diagnostics, status | Yes |
Number of auxiliary contacts | 2 |
Number of LEDs | 7 |
Number of normally closed (NC) | 4 |
Number of safety contacts | 4 |
Number of signalling outputs | 2 |
Safety classification |
Standards | EN IEC 60947-1 EN IEC 61508 |
Stop-Category | 0 |
Safety classification - Relay outputs |
PFH value | 2.00 x 10⁻⁸ /h |
Performance Level, stop 0, up to | e |
Category, Stop 0 | 4 |
Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 % |
Safety Integrity Level (SIL), Stop 0, suitable for applications in | 3 |
Mission time | 20 Year(s) |
Common Cause Failure (CCF), minimum | 65 |
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Terminal designations | IEC/EN 60947-1 |
Termination | rigid or flexible Screw terminals M20 x 1.5 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Width | 45 mm |
Height | 100 mm |
Depth | 121 mm |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature | -25 ... +45 °C |
Storage and transport temperature | -40 ... +85 °C |
Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
Restistance to shock | 30 g / 11 ms |
Rated impulse withstand voltage Uimp | 4 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Frequency range | 50 Hz 60 Hz |
Operating voltage | 230 VAC -15 % / +10 % |
Rated operating voltage | 230 VAC |
Rated AC voltage for controls, 50 Hz, minimum | 195.5 VAC |
Rated control voltage at AC 50 Hz, maximum | 253 VAC |
Rated AC voltage for controls, 60 Hz, minimum | 195.5 VAC |
Rated control voltage at AC 60 Hz, maximum | 253 VAC |
Electrical power consumption | 6 W |
Electrical power consumption | 7.8 VA |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 80 ms |
Drop-out delay in case of emergency, typically | 20 ms |
Pull-in delay at automatic start, maximum, typically | 100 ms |
Pull-in delay at RESET, typically | 20 ms |
Material of the contacts, electrical | Ag-Ni, self-cleaning, positive drive |
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 4 A |
Switching capacity, minimum | 10 VDC |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 250 VAC |
Switching capacity, maximum | 8 A |
Conduction resistance, maximum | 40 Ω |
Switching capacity, maximum | 24 VDC |
Switching capacity, maximum | 2 A |
EMC rating | EMC-Directive |
Indicated operating states | Position relay K2 Position relay K1 Internal operating voltage Ui Position relay K3 Position relay K5 |
Note (applications) | Safety sensor Guard system |
Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
Note (Wiring diagram) | The control system recognises wire-breakage and earth faults in the monitoring circuit. The example shows a 1-channel control with contact A for a guard door monitor; of which at least one contact has positive break; with external reset button (R). Relay outputs: Suitable for 1 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. The wiring diagram is shown with non-actuated limit switches and in de-energised condition. (H2) = Feedback circuit |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.