Schmersal : SRB202MSL-101181998
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | SRB202MSL |
Article number (order number) | 101181998 |
EAN (European Article Number) | 4250116202577 |
eCl@ss number, version 12.0 | 27-37-18-19 |
eCl@ss number, version 11.0 | 27-37-18-19 |
eCl@ss number, version 9.0 | 27-37-18-19 |
ETIM number, version 7.0 | EC001449 |
ETIM number, version 6.0 | EC001449 |
General data
Standards | EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress | EN 60068-2-78 |
Housing material | Glass-fibre reinforced thermoplastic, ventilated |
Gross weight | 400 g |
General data - Features
Electronic Fuse | Yes |
Wire breakage detection | Yes |
Cross-circuit detection | Yes |
Removable Terminals | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Reset after disconnection of supply voltage | Yes |
Earth connection detection | Yes |
Integral system diagnostics, status | Yes |
Number of auxiliary contacts | 2 |
Number of LEDs | 8 |
Number of normally closed (NC) | 2 |
Number of safety contacts | 2 |
Number of signalling outputs | 2 |
Safety classification |
Standards | EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category | 0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to | e |
Category, Stop 0 | 4 |
Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 % |
PFH value, Stop 0 | 2.00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in | 3 |
Mission time | 20 Year(s) |
Common Cause Failure (CCF), minimum | 65 |
Mechanical data
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Terminal designations | IEC/EN 60947-1 |
Termination | rigid or flexible Screw terminals M20 x 1.5 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Mechanical data - Dimensions
Width | 45 mm |
Height | 100 mm |
Depth | 121 mm |
Ambient conditions
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature | -25 ... +45 °C |
Storage and transport temperature | -40 ... +85 °C |
Resistance to vibrations | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage Uimp | 4 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Electrical data
Frequency range | 50 Hz 60 Hz |
Operating voltage | 24 VDC -10 % / +20 % |
Ripple voltage | 10 % |
Rated operating voltage | 24 VDC |
Rated AC voltage for controls at DC minimum | 20.4 VDC |
Rated control voltage at DC, maximum | 28.8 VDC |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 2 A |
Electrical power consumption | 5.6 W |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 60 ms |
Drop-out delay in case of emergency, typically | 17 ms |
Drop-out delay in case of "emergency stop", maximum | 20 ms |
Pull-in delay at automatic start, maximum, typically | 200 ms |
Material of the contacts, electrical | AgSn0, Ag-Ni, self-cleaning, positive drive |
Electrical data - Digital inputs
Conduction resistance, maximum | 40 Ω |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating | EMC-Directive |
Status indication
Indicated operating states | Position relay K2 Position relay K1 Internal operating voltage Ui Position relay K3 Position relay K5 Position of the muting signalling device LA |
Other data
Note (applications) | Muting function |
Note
Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
Wiring example
Note (Wiring diagram) | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. The control recognises cross-short, cable break and earth leakages in the monitoring circuit. The example shows a 2-channel control of 2 muting sensors and an external master reset button. The wiring diagram is shown with non-actuated muting sensors and in de-energised condition. (H2) = Feedback circuit F1 = Electronic fuse |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.