Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Opener (NC) Normally open contact (NO)Two-functions safety monitoring module (double evaluation)2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)2 Signalling outputs
Replacement article number | 101175605 |
Product type description | SRB202CA 24VDC |
Article number (order number) | 101176197 |
EAN (European Article Number) | 4250116201969 |
eCl@ss number, version 12.0 | 27-37-18-19 |
eCl@ss number, version 11.0 | 27-37-18-19 |
eCl@ss number, version 9.0 | 27-37-18-19 |
ETIM number, version 7.0 | EC001449 |
ETIM number, version 6.0 | EC001449 |
Available until | 31.12.2024 |
| cULus |
Standards | EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress | EN 60068-2-78 |
Housing material | Glass-fibre reinforced thermoplastic, ventilated |
Gross weight | 235 g |
Electronic Fuse | Yes |
Wire breakage detection | Yes |
Removable Terminals | Yes |
Start input | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Earth connection detection | Yes |
Integral system diagnostics, status | Yes |
Number of auxiliary contacts | 2 |
Number of inputs for NC | 3 |
Number of inputs for NO | 1 |
Number of LEDs | 6 |
Number of safety contacts | 2 |
Safety classification |
Standards | EN IEC 60947-5-1 EN IEC 61508 |
Stop-Category | 0 |
Safety classification - Relay outputs |
Performance Level, stop 0, up to | e |
Category, Stop 0 | 4 |
Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 % |
PFH value, Stop 0 | 2.00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), Stop 0, suitable for applications in | 3 |
Mission time | 20 Year(s) |
Common Cause Failure (CCF), minimum | 65 |
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Terminal designations | IEC/EN 60947-1 |
Termination | rigid or flexible Screw terminals M20 x 1.5 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Width | 22.5 mm |
Height | 100 mm |
Depth | 121 mm |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature | -25 ... +45 °C |
Storage and transport temperature | -40 ... +85 °C |
Resistance to vibrations | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock | 10 g / 11 ms |
Rated impulse withstand voltage Uimp | 4 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Operating voltage | 24 VDC -10 % / +20 % |
Ripple voltage | 10 % |
Rated operating voltage | 24 VDC |
Rated AC voltage for controls at DC minimum | 20.4 VDC |
Rated control voltage at DC, maximum | 28.8 VDC |
Electrical power consumption | 4.4 W |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 80 ms |
Drop-out delay in case of emergency, typically | 20 ms |
Pull-in delay at automatic start, maximum, typically | 100 ms |
ON delay at automatic start | Adjustable |
Pull-in delay at RESET, typically | 20 ms |
Material of the contacts, electrical | Ag-Ni, self-cleaning, positive drive |
Voltage, Utilisation category AC-15 | 250 VAC |
Current, Utilisation category AC-15 | 6 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 6 A |
Switching capacity, minimum | 10 VDC |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 250 VAC |
Switching capacity, maximum | 8 A |
Conduction resistance, maximum | 40 Ω |
Switching capacity, maximum | 24 VDC |
Switching capacity, maximum | 2 A |
EMC rating | EMC-Directive |
Indicated operating states | Position relay K2 Position relay K1 Internal operating voltage Ui Position relay K3 |
Note (applications) | Safety sensor Guard system Pull-wire emergency stop switches Emergency stop button |
Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
Note (Cross-circuit detection) | Level 1 |
Note (Wiring diagram) | The wiring diagram is shown with guard doors closed and in de-energised condition. Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. The control recognises cross-short, cable break and earth leakages in the monitoring circuit. Input level: the example shows a 2-channel control of an Emergency Stop command device (level 1) with external reset button (R), and guard door monitoring (level 2) with feedback circuit (H2). Automatic start (level 1): The automatic start is programmed by connecting the feedback circuit to the terminals X1/+24 V DC. Automatic start (level 2): The automatic start is programmed by connecting the feedback circuit to the terminals X2/+24 V DC. If the feedback circuit is not required, establish a bridge. 1 NC contact each time communicates the status of level 1 and level 2 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.