2-channel safety door monitoring2 Safety contacts, 2 Safety OutputPlug-in screw terminals with coding2 Signalling outputs1 Signalling output - failure massage dynamicDetects standstill using 1 or 2 impulse sensorsadditional standstill signal, e.g. PLC as second input channel2-channel time monitoring
Product type description | SRB-E-402FWS-TS |
Article number (order number) | 103014757 |
EAN (European Article Number) | 4030661511283 |
eCl@ss number, version 12.0 | 27-37-18-19 |
eCl@ss number, version 11.0 | 27-37-18-19 |
eCl@ss number, version 9.0 | 27-37-18-19 |
ETIM number, version 7.0 | EC001449 |
ETIM number, version 6.0 | EC001449 |
| cULus CCC |
Standards | EN IEC 62061 EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 60947-5-3 EN IEC 60947-5-5 EN IEC 61508 EN IEC 60204-1 EN IEC 60947-1 |
Climatic stress | EN 60068-2-78 |
Housing material | Glass-fibre reinforced thermoplastic, ventilated |
Gross weight | 190 g |
Electronic Fuse | Yes |
Wire breakage detection | Yes |
Cross-circuit detection | Yes |
Start input | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Reset edge detection | Yes |
Earth connection detection | Yes |
Integral system diagnostics, status | Yes |
Number of auxiliary contacts | 1 |
Number of inputs for NC | 4 |
Number of inputs for NO | 2 |
Number of LEDs | 6 |
Number of safety contacts | 2 |
Number of fail-safe digital outputs | 2 |
Number of signalling outputs | 1 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 62061 EN IEC 61508 |
Stop-Category | 0 |
Safety classification - Relay outputs |
Performance Level, up to | e |
Category | 4 |
Diagnostic Coverage (DC) Level | > 94 % |
PFH value | 1.25 x 10⁻⁸ /h |
PFD value | 5.30 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Common Cause Failure (CCF), minimum | 65 |
Safety classification - Fail-safe digital outputs |
Performance Level, up to | e |
Category | 4 |
PFH value | 2.66 x 10⁻⁹ /h |
PFD value | 2.42 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Terminal designations | IEC 60947-1 |
Termination | rigid or flexible Screw connection, plug-in |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.5 Nm |
Width | 22.5 mm |
Height | 98 mm |
Depth | 115 mm |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -40 ... +85 °C |
Resistance to vibrations | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Rated insulation voltage Ui | 250 V / 50 V |
Rated impulse withstand voltage Uimp, relay output | 4 kV |
Rated impulse withstand voltage Uimp, semiconductor output | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 2 |
Operating voltage | 24 VDC -20 % / +20 % |
Ripple voltage | 10 % |
Rated operating voltage | 24 VDC |
Operating current | 150 mA |
Rated AC voltage for controls at DC minimum | 19.2 VDC |
Rated control voltage at DC, maximum | 28.8 VDC |
Electrical power consumption | 3 W |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 10 ms |
Drop-out delay in case of emergency, typically | 10 ms |
Pull-in delay at automatic start, maximum, typically | 150 ms |
ON delay at automatic start | Adjustable |
Pull-in delay at RESET, typically | 150 ms |
Switching frequency, maximum | 0.3 Hz |
Material of the contacts, electrical | Ag-Ni, self-cleaning, positive drive |
Voltage drop Ud, maximum | 0.5 V |
Leakage current Ir, maximum | 1 mA |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 2 A |
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 4 A |
Switching capacity, minimum | 10 VDC |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 250 VAC |
Switching capacity, maximum | 6 A |
Conduction resistance, maximum | 40 Ω |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.1 A |
Switching capacity, maximum | 24 VDC |
Switching capacity, maximum | 1 A |
EMC rating | EMC-Directive |
Indicated operating states | Internal operating voltage Ui Baustein-Status Fault codes |
Note (applications) | safe standstill monitoring Fail-safe delay timer guard door monitoring |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.