Up to 2 light barrier pairs SLB 200 can be connected1 safety contact1 Signalling output
Note (Delivery capacity) | Not available! |
Product type description | SLB 200-C04-1R |
Article number (order number) | 101138897 |
EAN (European Article Number) | 4030661281537 |
eCl@ss number, version 12.0 | 27-27-27-01 |
eCl@ss number, version 11.0 | 27-27-27-01 |
eCl@ss number, version 9.0 | 27-27-27-01 |
ETIM number, version 7.0 | EC001831 |
ETIM number, version 6.0 | EC001831 |
Standards | EN IEC 61496-2 EN ISO 13849-1 EN IEC 61496-1 |
Housing material | Glass-fibre, reinforced thermoplastic |
Reaction time, maximum | 30 ms |
Gross weight | 350 g |
Start input | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Reset edge detection | Yes |
Integral system diagnostics, status | Yes |
Number of LEDs | 4 |
Number of safety contacts | 1 |
Number of signalling outputs | 1 |
Safety classification |
Standards | EN IEC 61508 |
Performance Level, up to | d |
Category | 2 |
Safety Integrity Level (SIL), suitable for applications in | 2 |
Mission time | 20 Year(s) |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Termination | Screw terminals M20 x 1.5 |
Cable section, maximum | 4 mm² |
Note | All indications including the conductor ferrules. |
Width | 45 mm |
Height | 84 mm |
Depth | 118 mm |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature | +0 ... +50 °C |
Storage and transport temperature | -20 ... +80 °C |
Resistance to vibrations | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock | 10 g / 16 ms |
Rated impulse withstand voltage Uimp | 4.8 kV |
Overvoltage category | II |
Degree of pollution | 3 |
Operating voltage | 24 VDC -20 % / +20 % |
Rated operating voltage | 24 VDC |
Operating current | 180 mA |
Utilisation category AC-15 | 250 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 2 A |
Time to readiness, maximum | 300 ms |
Switching frequency, maximum | 10 Hz |
EMC rating | EMC-Directive |
Indicated operating states | RELAY, green: safety contact closed RELAY, red: safety contact open |
Note (applications) | Safety light barriers |
Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. In order to set for the desired mode of operation and number of light barriers connected, remove the front cover of the safety monitoring module. As supplied all switches are in Position 1. The required functions can be selected by means of the internal DIP switches. Test push button (T): The test push button is connected to X13 and X14 in order to carry out a check of the light barrier monitoring function. The terminals X15 and X16 must be bridged. |
DIP switch 1, Position 1 | With contactor control |
DIP switch 1, Position 2 | Without contactor control |
DIP switch 2, Position 1 | With start-/restart interlock |
DIP switch 2, Position 2 | Without start-/restart interlock |
DIP switch 3, Position 1 | Connection of 2 light barrier(s) |
DIP switch 3, Position 2 | Connection of 1 light barrier(s) |
Note (Wiring diagram) | The wiring diagram is shown for the de-energised condition. Monitoring up to two pairs of light barrier devices and the power contactors using the SLB 200-C safety monitoring module Contactor check: To monitor an external contactor, the feedback circuit is connected to X17 and X18. The terminals X19 and X20 must be bridged. Start push button (S): The start push button can be used to start the monitoring of the light barriers for a new start or after an interruption. The terminals X3 and X4 must be bridged. It is also possible to connect only one pair of light barrier devices. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.