Schmersal : SFB-PN-IRT-8M12-IOP-V2-103040357
SFB-PN-IRT-8M12-IOP-V2
SFB-PN-IRT-8M12-IOP-V2-103040357
Safety fieldbox for PROFINET/PROFIsafeFor connection of up to 8 safety switching devicesIntegrated dual-port switch, IRT-capableProtection class IP67
- Safety fieldbox for PROFINET/PROFIsafe
- For connection of up to 8 safety switching devices
- Integrated dual-port switch, IRT-capable
- Protection class IP67
Ordering data
Product type description | SFB-PN-IRT-8M12-IOP-V2 |
Article number (order number) | 103040357 |
EAN (European Article Number) | 4030661561554 |
eCl@ss number, version 12.0 | 27-24-26-04 |
eCl@ss number, version 11.0 | 27-24-26-04 |
eCl@ss number, version 9.0 | 27-24-26-04 |
ETIM number, version 7.0 | EC001599 |
ETIM number, version 6.0 | EC001599 |
Approvals - Standards
| TÜV cULus UKCA |
General data
Standards | EN IEC 61131-1 EN IEC 61131-2 EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
Housing material | Thermoplastic, Polyamide PA 6 GF |
Material of the identification label | Plastic, Polyamide PA |
Material of viewing window | Polyamide PACM 12 |
Material of electronic encapsulation | Polyurethane 2K PU |
Gross weight | 655 g |
General data - Features
Integral system diagnostics, general | Yes |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Safety classification - Safety inputs 2-channels |
Performance Level, up to | e |
Category | 4 |
Diagnostic Coverage (DC) Level | 99 % |
PFH value | 1.10 x 10⁻⁹ /h |
PFDavg | 9.60 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Response time of local safety input ⇒ Fieldbus, maximum | 20 ms |
Notice | The SFB fulfils the requirements as PDDB (proximity switch with defined behaviour under fault conditions) according to EN 60947-5-3 in combination with magnetic sensors (2 NC contacts) up to PL e / SIL 3. |
Safety classification - Safety inputs 1-channel |
Performance Level, up to | d |
Category | 2 |
Diagnostic Coverage (DC) Level | 90 % |
PFH value | 2.30 x 10⁻⁷ /h |
PFDavg | 2.00 x 10⁻² |
Safety Integrity Level (SIL), suitable for applications in | 1 |
Mission time | 20 Year(s) |
Response time of local safety input > Fieldbus, maximum | 20 ms |
Test interval for error detection | 10 s |
Safety classification - Safety outputs 1-channel |
Performance Level, up to | d |
Category | 3 |
Diagnostic Coverage (DC) Level | 90 % |
PFH value | 1.00 x 10⁻⁷ /h |
PFDavg | 8.80 x 10⁻³ |
Safety Integrity Level (SIL), suitable for applications in | 2 |
Mission time | 20 Year(s) |
Reaction time Fieldbus > local safety output | 50 ms |
Safety classification - Safety outputs 2-channels |
Performance Level, up to | e |
Category | 4 |
Diagnostic Coverage (DC) Level | 99 % |
PFH value | 1.20 x 10⁻⁹ /h |
PFDavg | 1.10 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Notes (Safety Integrity Level) | This product must only be replaced in the application by an identical product of type SFB-PN-IRT-8M12-IOP-V2 with part no. 103040357. The older product version has a lower safety level. |
Mission time | 20 Year(s) |
Reaction time Fieldbus > local safety output | 50 ms |
Mechanical data
Mounting | Screws |
Type of the fixing screws | 2x M6 |
Tightening torque of the fixing screws, maximum | 3 Nm |
Type of the fixing screws, viewing window | 2x TX10 (Torx) |
Tightening torque of the fastening screws for the viewing window, maximum | 0.6 Nm |
Mechanical data - Connection technique
Termination | M12 Connector socket/connector |
Terminal connector, Input/Output | X0 - X7: M12, 8-pole, A-coded |
Terminal Connector, Power I/O | M12 POWER, 4-pole, T-coded |
Terminal Connector, Field bus | M12, 4-pole, D-coded |
Tightening torque of electrical connection, minimum | 0.8 Nm |
Tightening torque of electrical connection, maximum | 1.5 Nm |
Mechanical data - Dimensions
Length | 222.8 mm |
Width | 63 mm |
Height | 36.1 mm |
Ambient conditions
Degree of protection | IP66 IP67 |
Ambient temperature | -25 ... +55 °C |
Storage and transport temperature | -25 ... +70 °C |
Relative humidity, minimum | 10 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm / 5 g |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data
Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
Current consumption | 200 mA |
Rated operating voltage | 24 VDC |
Operating current | 10,000 mA |
Note (Electrical data, Fuse rating) | External fuse protection required ≤ 10A slow blow when used to UL 61010. |
Time to readiness, maximum | 8,000 ms |
Device Watchdog Time | 10 ms |
Device Acknowledgement Time, maximum | 25 ms |
Reaction Time Safety Input, maximum | 20 ms |
Reaction Time Safety Output, maximum | 50 ms |
Electrical data - Communication protocols
Feldbus Protokoll | PROFINET / PROFIsafe |
Fieldbus specification | V2.3, Conformance Class C |
Specification safety fieldbus | V2.4 |
Fieldbus properties | Media Redundancy Protocol (MRP) Fast Start Up |
Fieldbus network load class | 3 |
Transfer rate | 100 Mbit/s Full Duplex |
Adressing | Discovery and Configuration Protocol (DCP) |
Integrated switch | Dual Port, 100 Mbit/s, IRT capable |
Fieldbus services | I&M0 ... I&M3, SNMP, LLDP |
Service interface | WEB-Interface HTTP |
Electrical data - Device Ports
Bezeichnung, Geräteanschlüsse | X0 ... X7 |
Cable length, device port | 30 m |
Electrical data - Power supply external devices
Designation, Power supply | A1 and A2 |
Rated operating voltage | 24 VDC |
Rated operating current | 800 mA |
Internal electrical fuse | 1.5 A (Integrated automatic resettable fuse) |
Electrical data - Safety digital inputs
Designation, Safety inputs | X1 and X2 |
Switching thresholds | −3 V … 5 V (Low) 13 V ... 30 V (High) |
Current consumption at 24 V | 6 mA |
Permissible residual drive current | 1 mA |
Test pulse duration, minimum | 0.01 ms |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 20 ms |
Test pulse interval, maximum | 120,000 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Safety digital outputs
Designation, Safety outputs | DO |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 2 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.8 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.8 A |
Note, Utilisation category DC-13 | Inductive load, maximum 400 mH |
Switching frequency, maximum | 1 Hz |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 15 ms |
Test pulse interval, maximum | 500 ms |
Classification ZVEI CB24I, Source | C1 |
Classification ZVEI CB24I, Sink | C1 |
Electrical data - Diagnostic inputs / FB-Interface
Designation, Diagnostic inputs / FB-Interface | DI |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24V | 12 mA |
Input debounce filter | 10 ms |
Data transfer rate FB-Interface | 19,2 kBaud |
Electrical data - Test pulse output
Designation, Test pulse outputs | Y1 and Y2 |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 1 V |
Current leakage Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Y1 rated current at 24 V | 15 mA |
Y2 rated current at 24 V | 10 mA |
Y2 rated current at 0 V | 30 mA |
Test pulse interval, typical | 500 ms |
Test pulse duration, maximum | 1 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 |
LED status display - LED 01
LED status | Error LED device port |
LED position | E: 0 ... 7 |
LED colour | green/red |
LED status display - LED 02
LED status | Input LED device port |
LED position | I: 0 ... 7 |
LED colour | Yellow |
LED status display - LED 03
LED status | LED Link Ethernet port |
LED position | L: P1 + P2 |
LED colour | Green |
LED status display - LED 04
LED status | LED Activity Ethernet port |
LED position | A: P1 + P2 |
LED colour | Yellow |
LED status display - LED 05
LED status | System fault LED |
LED position | "SF": Module |
LED colour | green/red |
LED status display - LED 06
LED status | BUS fault LED |
LED position | "BF": Module |
LED colour | Red |
LED status display - LED 07
LED status | Fieldbox error LED |
LED position | "Err": Module |
LED colour | green/red |
LED status display - LED 08
LED status | Power-LED fieldbox |
LED position | "Pwr": Module |
LED colour | Green |
Other data
Note (applications) | Safe field box with decentralised I/Os |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.