alt
alt

SFB-EC-8M12-IOP-103047531
SFB-EC-8M12-IOP

Safety fieldbox for EtherCAT with FSoEFor connection of up to 8 safety switching devicesIntegrated dual-port switchProtection class IP66, IP67

  • Safety fieldbox for EtherCAT with FSoE
  • For connection of up to 8 safety switching devices
  • Integrated dual-port switch
  • Protection class IP66, IP67

Ordering data

Product type description

SFB-EC-8M12-IOP

Article number (order number)

103047531

EAN (European Article Number)

4030661628707

eCl@ss number, version 12.0

27-24-26-04

eCl@ss number, version 11.0

27-24-26-04

eCl@ss number, version 9.0

27-24-26-04

ETIM number, version 7.0

EC001599

ETIM number, version 6.0

EC001599

Approvals - Standards

Certificates

TÜV

cULus

UKCA

General data

Standards

EN IEC 61131-1

EN IEC 61131-2

EN ISO 13849-1

EN IEC 60947-5-3

EN IEC 61508

Housing material

Thermoplastic, Polyamide PA 6 GF

Material of the identification label

Plastic, Polyamide PA

Material of viewing window

Polyamide PACM 12

Material of electronic encapsulation

Polyurethane 2K PU

Gross weight

597 g

General data - Features

Integral system diagnostics, general

Yes

Safety classification
Standards

EN ISO 13849-1

EN IEC 61508

Safety classification - Safety inputs 2-channels
Performance Level, up to

e

Category

4

Diagnostic Coverage (DC) Level

99 %

PFH value

1.10 x 10⁻⁹ /h

PFDavg

9.60 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Response time of local safety input ⇒ Fieldbus, maximum

30 ms

Notice

The SFB fulfils the requirements as PDDB (proximity switch with defined behaviour under fault conditions) according to EN 60947-5-3 in combination with magnetic sensors (2 NC contacts) up to PL e / SIL 3.

Safety classification - Safety inputs 1-channel
Performance Level, up to

d

Category

2

Diagnostic Coverage (DC) Level

90 %

PFH value

2.30 x 10⁻⁷ /h

PFDavg

2.00 x 10⁻²

Safety Integrity Level (SIL), suitable for applications in

1

Mission time

20 Year(s)

Response time of local safety input > Fieldbus, maximum

30 ms

Test interval for error detection

10 s

Safety classification - Safety outputs 1-channel
Performance Level, up to

d

Category

3

Diagnostic Coverage (DC) Level

90 %

PFH value

1.00 x 10⁻⁷ /h

PFDavg

8.80 x 10⁻³

Safety Integrity Level (SIL), suitable for applications in

2

Mission time

20 Year(s)

Reaction time Fieldbus > local safety output

50 ms

Safety classification - Safety outputs 2-channels
Performance Level, up to

e

Category

4

Diagnostic Coverage (DC) Level

99 %

PFH value

1.20 x 10⁻⁹ /h

PFDavg

1.10 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Reaction time Fieldbus > local safety output

50 ms

Mechanical data

Mounting

Screws

Type of the fixing screws

2x M6

Tightening torque of the fixing screws, maximum

3 Nm

Type of the fixing screws, viewing window

2x TX10 (Torx)

Tightening torque of the fastening screws for the viewing window, maximum

0.6 Nm

Mechanical data - Connection technique

Termination

M12 Connector socket/connector

Terminal connector, Input/Output

X0 - X7: M12, 8-pole, A-coded

Terminal Connector, Power I/O

M12 POWER, 4-pole, T-coded

Terminal Connector, Field bus

M12, 4-pole, D-coded

Tightening torque of electrical connection, minimum

0.8 Nm

Tightening torque of electrical connection, maximum

1.5 Nm

Mechanical data - Dimensions

Length

222.8 mm

Width

63 mm

Height

36.1 mm

Ambient conditions

Degree of protection

IP66

IP67

Ambient temperature

-25 ... +55 °C

Storage and transport temperature

-25 ... +70 °C

Relative humidity, minimum

10 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

Resistance to vibrations

10 … 150 Hz, amplitude 0.35 mm / 5 g

Restistance to shock

30 g / 11 ms

Protection class

III

Permissible installation altitude above sea level, maximum

2,000 m

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 % (stabilised PELV power supply)

Current consumption

200 mA

Rated operating voltage

24 VDC

Operating current

10,000 mA

Note (Electrical data, Fuse rating)

External fuse protection required ≤ 10A slow blow when used to UL 61010.

Time to readiness, maximum

12,000 ms

Device Watchdog Time

12 ms

Device Acknowledgement Time, maximum

25 ms

Reaction Time Safety Input, maximum

30 ms

Reaction Time Safety Output, maximum

50 ms

Electrical data - Communication protocols

Feldbus Protokoll

EtherCAT / FSoE

Fieldbus specification

V1.0.10

Specification safety fieldbus

V1.2.0

Transfer rate

100 Mbit/s Full Duplex

Adressing

Topology dependent

Integrated switch

Dual Port, 100 Mbit/s

Service interface

WEB-Interface HTTP

Electrical data - Device Ports

Bezeichnung, Geräteanschlüsse

X0 ... X7

Cable length, device port

30 m

Electrical data - Power supply external devices

Designation, Power supply

A1 and A2

Rated operating voltage

24 VDC

Rated operating current

800 mA

Internal electrical fuse

1.5 A (Integrated automatic resettable fuse)

Electrical data - Safety digital inputs

Designation, Safety inputs

X1 and X2

Switching thresholds

−3 V … 5 V (Low)

13 V ... 30 V (High)

Current consumption at 24 V

6 mA

Permissible residual drive current

1 mA

Test pulse duration, minimum

0.01 ms

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

20 ms

Test pulse interval, maximum

120,000 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Designation, Safety outputs

DO

Design of control elements

short-circuit proof, p-type

Voltage drop Ud, maximum

2 V

Leakage current Ir, maximum

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.8 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.8 A

Note, Utilisation category DC-13

Inductive load, maximum 400 mH

Switching frequency, maximum

1 Hz

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

15 ms

Test pulse interval, maximum

500 ms

Classification ZVEI CB24I, Source

C1

Classification ZVEI CB24I, Sink

C1

Electrical data - Diagnostic inputs / FB-Interface

Designation, Diagnostic inputs / FB-Interface

DI

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

12 mA

Input debounce filter

10 ms

Data transfer rate FB-Interface

19,2 kBaud

Electrical data - Test pulse output

Designation, Test pulse outputs

Y1 and Y2

Design of control elements

short-circuit proof, p-type

Voltage drop Ud, maximum

1 V

Current leakage Ir, maximum

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Y1 rated current at 24 V

15 mA

Y2 rated current at 24 V

10 mA

Y2 rated current at 0 V

30 mA

Test pulse interval, typical

500 ms

Test pulse duration, maximum

1 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

LED status display - LED 01

LED status

Error LED device port

LED position

E: 0 ... 7

LED colour

green/red

LED status display - LED 02

LED status

Input LED device port

LED position

I: 0 ... 7

LED colour

Yellow

LED status display - LED 03

LED status

Link / Activity-LED Ethernet Port

LED position

L / A: IN + OUT

LED colour

Green

LED status display - LED 05

LED status

EtherCAT RUN LED

LED position

"RUN": Module

LED colour

Green

LED status display - LED 06

LED status

EtherCAT error LED

LED position

"ERR": Module

LED colour

Red

LED status display - LED 07

LED status

Fieldbox Diag-LED

LED position

"Diag": Module

LED colour

green/red

LED status display - LED 08

LED status

Power-LED fieldbox

LED position

"Pwr": Module

LED colour

Green

Other data

Note (applications)

Safe field box with decentralised I/Os

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

Z4V10H 335-11Z-M20-151162579
Schmersal
Z4V7H 335-02Z-RMS-151217130
Schmersal
T4V7H 335-03Z-151147375
Schmersal
Z4V7H 335-11Z-M20-151161691
Schmersal
Z4V7H 335-11Z-RMS-1637-151094266
Schmersal
Z4V7H 335-11Z-U180-151091526
Schmersal
Z4V7H 335-11Z-1637-151088173
Schmersal
T4V7H 335-20ZH-151082571
Schmersal
Z4V7H 335-11Z-U180-M20-2079-1-151171730
Schmersal
Z4V7H 335-11Z-RVA-2622-151195401
Schmersal
Z4V7H 335-11Z-2079-1-151118889
Schmersal
T4V7H 335-12Z-M20-101172022
Schmersal