Schmersal : RSS260-I1-LSTM12-4-0,25M-AS-103014762
RSS260-I1-LSTM12-4-0,25M-AS
RSS260-I1-LSTM12-4-0,25M-AS-103014762
Individual coding with RFID technologyCoding level "High" according to ISO 14119Safety sensor, electronicThermoplastic enclosureSmall body, high switching distanceProtection class IP65 / IP67
- Individual coding with RFID technology
- Coding level "High" according to ISO 14119
- Safety sensor, electronic
- Thermoplastic enclosure
- Small body, high switching distance
- Protection class IP65 / IP67
Ordering data
Product type description | RSS260-I1-LSTM12-4-0,25M-AS |
Article number (order number) | 103014762 |
EAN (European Article Number) | 4030661507606 |
eCl@ss number, version 12.0 | 27-27-46-01 |
eCl@ss number, version 11.0 | 27-27-24-03 |
eCl@ss number, version 9.0 | 27-27-24-03 |
ETIM number, version 7.0 | EC001829 |
ETIM number, version 6.0 | EC001829 |
Approvals - Standards
| TÜV cULus ASi-SaW FCC UKCA ANATEL |
General data
Standards | EN IEC 62026-2 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Individual coding |
Coding level according to EN ISO 14119 | High |
Working principle | RFID |
Housing material | Thermoplastic hotmelt |
Reaction time, maximum | 100 ms |
Duration of risk, maximum | 200 ms |
Gross weight | 83 g |
General data - Features
Coding | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of actuating directions | 2 |
Safety classification |
Standards | EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 3.93 x 10⁻¹⁰ /h |
PFD value | 6.89 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switching distance Sn | 12 mm 9 mm (in case of approach from side) |
Assured switching distance "ON", frontal | 10 mm |
Assured switching distance "OFF", frontal | 18 mm |
Assured switching distance "ON", lateral | 6 mm |
Assured switching distance "OFF", lateral | 15 mm |
Hysteresis (Switching distance), maximum | 2 mm |
Repeat accuracy R | 0.5 mm |
Mechanical data - Connection technique
Length of cable | 0.25 m |
Termination | Connecting cable with M12 connector, straight, 4-pole |
Mechanical data - Dimensions
Length of sensor | 18 mm |
Width of sensor | 40 mm |
Height of sensor | 29.5 mm |
Ambient conditions
Degree of protection | IP65 IP67 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -25 ... +85 °C |
Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Ambient conditions - Insulation values
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data
Time to readiness, maximum | 2,000 ms |
Switching frequency, maximum | 1 Hz |
Electrical data - AS Interface
Rated operating voltage | 18 ... 31.6 VDC (Protection against polarity reversal) |
AS-i Current consumption, maximum | 100 mA |
Electrical data - AS-Interface specification
AS-i Specification | Safety-Slave |
AS-i Version | V 2.1 |
AS-i Profile | S-0.B.F.E |
AS-i, IO-Code | 0x0 |
AS-i, ID-Code | 0xB |
AS-i, ID-Code1 | 0xF |
AS-i, ID-Code2 | 0xE |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 … DO 3 | No Function |
AS-i Parameter bits, P0 | Actuator in |
AS-i Parameter bits, P1 | Enabling inhibit (tamper protection time) active (FID)) |
AS-i Parameter bits, P2 | No function |
AS-i Parameter bits, P3 | Internal device error (FID) |
Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
Note (LED switching conditions display) | (1) green/red LED (AS-i Duo LED):Supply voltage / communication error / slave address = 0 / periphery error detected / Tamper protection time active (2) yellow LED: device condition (enabling status) / hysteresis signal / device error |
Pin assignment
PIN 1 | AS-Interface + |
PIN 2 | n.c. (≤ 30 VDC) |
PIN 3 | AS-Interface - |
PIN 4 | n.c. (≤ 30 VDC) |
Scope of delivery
Scope of delivery | Actuator must be ordered separately. |
Note (scope of delivery, number and type) | Actuator incl. mounting plate |
Accessory
Recommendation (actuator) | RST260-1 |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.