Individual coding with RFID technologyCoding level "High" according to ISO 14119without latchingThermoplastic enclosureRFID-technology for needs-based protection against tamperingoptionally with integrated magnetic latching
Product type description | RSS 36-I1-ST-AS |
Article number (order number) | 103001536 |
EAN (European Article Number) | 4030661426242 |
eCl@ss number, version 12.0 | 27-27-46-01 |
eCl@ss number, version 11.0 | 27-27-24-03 |
eCl@ss number, version 9.0 | 27-27-24-03 |
ETIM number, version 7.0 | EC001829 |
ETIM number, version 6.0 | EC001829 |
| TÜV cULus ASi-SaW ECOLAB UKCA ANATEL |
Standards | EN IEC 62026-2 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Individual coding |
Coding level according to EN ISO 14119 | High |
Working principle | RFID |
Frequency band RFID | 125 kHz |
Transmitter output RFID, maximum | -6 dB/m |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Reaction time, maximum | 100 ms |
Duration of risk, maximum | 200 ms |
Gross weight | 91 g |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of actuating directions | 3 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 5.13 x 10⁻¹⁰ /h |
PFD value | 3.24 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | Actuating speed Operations for door weights ≤ 5 kg |
Type of the fixing screws | 2x M4 (cylinder head screws with washers DIN 125A / form A) |
Tightening torque of the fixing screws, minimum | 2.2 Nm |
Tightening torque of the fixing screws, maximum | 2.5 Nm |
Switch distance, typical | 12 mm |
Assured switching distance "ON" Sao | 10 mm |
Assured switching distance "OFF" Sar | 20 mm |
Hysteresis (Switching distance), maximum | 2 mm |
Repeat accuracy R | 0.5 mm |
Note (Repeat accuracy R) | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm. |
Termination | Connector plug M12, 4-pole, (A-coding) |
Length of sensor | 22 mm |
Width of sensor | 106.3 mm |
Height of sensor | 25 mm |
Degree of protection | IP65 IP67 IP69 |
Ambient temperature | -25 ... +70 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, maximum | 93 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Time to readiness, maximum | 5,000 ms |
Switching frequency, maximum | 1 Hz |
Rated operating voltage | 18 ... 31.6 VDC (Protection against polarity reversal) |
AS-i Current consumption, maximum | 100 mA |
AS-i Specification | Safety-Slave |
AS-i Version | V 3.0 |
AS-i Profile | S-0.B.F.E |
AS-i, IO-Code | 0x0 |
AS-i, ID-Code | 0xB |
AS-i, ID-Code1 | 0xF |
AS-i, ID-Code2 | 0xE |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 … DO 3 | No Function |
AS-i Parameter bits, P0 | Actuator in |
AS-i Parameter bits, P1 | Enabling inhibit (tamper protection time) active (FID)) |
AS-i Parameter bits, P2 | No function |
AS-i Parameter bits, P3 | Internal device error (FID) |
Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Note (LED switching conditions display) | (1) green/red LED (AS-i Duo LED):Supply voltage / communication error / slave address = 0 / periphery error detected / Tamper protection time active (2) yellow LED: device condition (enabling status) / hysteresis signal / device error |
PIN 1 | AS-Interface + |
PIN 2 | n.c. (≤ 30 VDC) |
PIN 3 | AS-Interface - |
PIN 4 | n.c. (≤ 30 VDC) |
Scope of delivery | Actuator must be ordered separately. |
Recommendation (actuator) | RST 36-1 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.