Guard locking monitoredconnector plug M12, 8-polePower to lockserial diagnostic outputenabling signal, when safety guard closed and locked (without force monitoring)Thermoplastic enclosureSafety switches must be used as end stop40 mm x 179 mm x 40 mmElectronic contact-free, coded systemVariably adjustable latching3 LEDs to show operating conditionsSensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontallyIntelligent diagnosisSelf-monitoring series-wiring
Note (Delivery capacity) | Not available! |
Product type description | MZM 120 BM ST2-SD2PRE-A |
Article number (order number) | 101215717 |
EAN (European Article Number) | 4030661419343 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| cULus |
Standards | EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
Working principle | inductive |
Housing material | Glass-fibre, reinforced thermoplastic |
Reaction time, maximum | 150 ms |
Duration of risk, maximum | 150 ms |
Gross weight | 150 g |
Power to lock | Yes |
Actuator monitored | Yes |
Solenoid interlock monitored | Yes |
Serial diagnostics | Yes |
Latching | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of safety contacts | 2 |
Safety classification |
Standards | EN IEC 60947-5-3 EN IEC 61508 |
PFH value | 4.30 x 10⁻⁹ /h |
Mission time | 20 Year(s) |
Performance Level, up to | e |
Category | 4 |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | Operations for door weights ≤ 5 kg |
Holding force | 500 N |
Latching force, minimum | 30 N |
Latching force, maximum | 80 N |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination | Connector plug M12, 8-pole |
Length of sensor | 40 mm |
Width of sensor | 40 mm |
Height of sensor | 177.5 mm |
Degree of protection | IP67 IP69K |
Ambient temperature | -25 ... +55 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | II |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
No-load supply current I0, typical | 600 mA |
Operating current | 1,000 mA |
Time to readiness, maximum | 4,000 ms |
Switching frequency, approx. | 1 Hz |
Electrical fuse rating, maximum | 2 A |
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time | 100 % |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 5 mA |
Rated operating current (safety outputs) | 250 mA |
Voltage drop Ud, maximum | 1 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage drop Ud, maximum | 2 V |
Designation, Serial diagnostic SD | OUT |
Operation current | 150 mA |
Design of control elements | short-circuit proof, p-type |
Wiring capacitance | 50 nF |
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB available: LED green |
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT serial diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN serial diagnostic input |
PIN 9 | without function |
Scope of delivery | Actuator must be ordered separately. |
Recommendation (actuator) | MZM 120-B1.1 |
Note (General) | As long as the safety guard remains closed, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.