Guard locking monitoredconnector plug M12, 8-polePower to lockenabling signal, when safety guard closed and locked (without force monitoring)Thermoplastic enclosureSafety switches must be used as end stop40 mm x 179 mm x 40 mmElectronic contact-free, coded systemVariably adjustable latching3 LEDs to show operating conditionsSensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontallyIntelligent diagnosisSelf-monitoring series-wiring
- Guard locking monitored
- connector plug M12, 8-pole
- Power to lock
- enabling signal, when safety guard closed and locked (without force monitoring)
- Thermoplastic enclosure
- Safety switches must be used as end stop
- 40 mm x 179 mm x 40 mm
- Electronic contact-free, coded system
- Variably adjustable latching
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Intelligent diagnosis
- Self-monitoring series-wiring
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | MZM 120 BM ST2-1P2PW2RE-A |
Article number (order number) | 101215716 |
EAN (European Article Number) | 4030661419336 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
| cULus |
General data
Standards | EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508 |
Working principle | inductive |
Housing material | Glass-fibre, reinforced thermoplastic |
Reaction time, maximum | 150 ms |
Duration of risk, maximum | 150 ms |
Gross weight | 150 g |
General data - Features
Power to lock | Yes |
Actuator monitored | Yes |
Solenoid interlock monitored | Yes |
Latching | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of safety contacts | 2 |
Safety classification |
Standards | EN IEC 60947-5-3 EN IEC 61508 |
PFH value | 4.30 x 10⁻⁹ /h |
Mission time | 20 Year(s) |
Safety classification - Interlocking function
Performance Level, up to | e |
Category | 4 |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | Operations for door weights ≤ 5 kg |
Holding force | 500 N |
Latching force, minimum | 30 N |
Latching force, maximum | 80 N |
Mechanical data - Connection technique
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Termination | Connector plug M12, 8-pole |
Mechanical data - Dimensions
Length of sensor | 40 mm |
Width of sensor | 40 mm |
Height of sensor | 177.5 mm |
Ambient conditions
Degree of protection | IP67 IP69K |
Ambient temperature | -25 ... +55 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | II |
Ambient conditions - Insulation values
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data
No-load supply current I0, typical | 600 mA |
Operating current | 50 mA |
Time to readiness, maximum | 4,000 ms |
Switching frequency, approx. | 1 Hz |
Electrical fuse rating, maximum | 2 A |
Electrical data - Magnet control
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time | 100 % |
Electrical data - Safety digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 5 mA |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) | 250 mA |
Voltage drop Ud, maximum | 1 V |
Leakage current Ir, maximum | 0.5 mA |
Electrical data - Diagnostic outputs
Voltage drop Ud, maximum | 2 V |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB available: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT Diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN Solenoid control |
PIN 9 | without function |
Scope of delivery
Scope of delivery | Actuator must be ordered separately. |
Accessory
Recommendation (actuator) | MZM 120-B1.1 |
Note
Note (General) | As long as the safety guard remains closed, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.
Similar Products
Can't find the product you're looking for?
LET US HELP YOU
Can't Find the Product You're Looking For? Let Us Know, and We'll Source It for You!
Are you searching for products not listed on our website or out of stock? Let us know your requirements, and our expert team will contact you as soon as possible to find the most suitable solution for you.