Connector M12, 8-polePower to lockserial diagnostic outputAutomatic latchingSolenoid interlocks with innovating and unique operating principle40 mm x 179 mm x 40 mmElectronic contact-free, coded systemThermoplastic enclosureMax. length of the sensor chain 200 m3 LEDs to show operating conditionsSensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontallyIntelligent diagnosisSelf-monitoring series-wiring
Note (Delivery capacity) | Not available! |
Product type description | MZM 100 B ST2-SD2PREM-A-2930-DU |
Article number (order number) | 103046451 |
EAN (European Article Number) | 4030661567839 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| TÜV cULus UKCA |
Standards | EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Universal coding |
Coding level according to EN ISO 14119 | Low |
Working principle | inductive |
Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Reaction time, maximum | 150 ms |
Duration of risk, maximum | 150 ms |
Gross weight | 620 g |
Power to lock | Yes |
Actuator monitored | Yes |
Serial diagnostics | Yes |
Latching | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of safety contacts | 2 |
Number of series-wiring of sensors | 31 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 3.54 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | Actuating speed ≤ 0.5 m/s Operations for door weights ≤ 5 kg |
Holding force, typically | 750 N |
Holding force, guaranteed | 500 N |
Latching force, minimum | 45 N |
Latching force, maximum | 115 N |
Type of the fixing screws | 2x M6 |
Tightening torque of the fixing screws | 8 Nm |
Assured switching distance "ON" Sao | 0 mm |
Assured switching distance "OFF" Sar | 1 mm |
Length of sensor chain, maximum | 200 m |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination | Connector M12, 8-pole |
Length of sensor | 40 mm |
Width of sensor | 40 mm |
Height of sensor | 177.5 mm |
Degree of protection | IP65 IP67 |
Ambient temperature | -25 ... +55 °C |
Storage and transport temperature | -25 ... +70 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm / 5 g |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
No-load supply current I0, typical | 100 mA |
Current consumption with magnet ON, average | 350 mA |
Current consumption with magnet ON, peak | 550 mA / 10 ms |
Rated operating voltage | 24 VDC |
Operating current | 1,100 mA |
Required rated short-circuit current | 100 A |
External wire and device fuse rating | 2 A gG |
Time to readiness, maximum | 4,000 ms |
Switching frequency, maximum | 1 Hz |
Designation, Magnet control | IN |
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 10 mA |
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 40 ms |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Designation, Safety inputs | X1 and X2 |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 5 mA |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 100 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Designation, Safety outputs | Y1 and Y2 |
Rated operating current (safety outputs) | 250 mA |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 1 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Test pulse interval, typical | 1000 ms |
Test pulse duration, maximum | 1 ms |
Classification ZVEI CB24I, Source | C1 |
Classification ZVEI CB24I, Sink | C1 |
Design of control elements | short-circuit proof, p-type |
Designation, Serial diagnostic SD | OUT |
Operation current | 150 mA |
Design of control elements | short-circuit proof, p-type |
Wiring capacitance | 50 nF |
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT serial diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN serial diagnostic input |
Scope of delivery | Actuator must be ordered separately. |
Recommendation (actuator) | MZM 100-B1.1 |
Note (General) | As long as the actuating unit is applied to the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.