Power to lockActuator monitoredPermanent magnetSolenoid interlockThermoplastic enclosureIntegrated AS-Interface40 mm x 179 mm x 40 mmSolenoid interlocks (for the protection of man) with innovating and unique operating principleElectronic contact-free, coded system3 LEDs to show operating conditionsAutomatic latchingSensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontallyIntelligent diagnosis
Note (Delivery capacity) | Not available! |
Product type description | MZM 100 B ST-AS REMAP-DU |
Article number (order number) | 103044829 |
EAN (European Article Number) | 4030661563961 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| TÜV cULus ASi-SaW UKCA |
Standards | EN IEC 62026-2 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Universal coding |
Coding level according to EN ISO 14119 | Low |
Working principle | inductive |
Housing material | Glass-fibre, reinforced thermoplastic |
Reaction time, maximum | 150 ms |
Duration of risk, maximum | 150 ms |
Gross weight | 707 g |
Power to lock | Yes |
Actuator monitored | Yes |
Latching | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Safety classification |
Standards | EN IEC 60947-5-3 EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 5.00 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | Actuating speed ≤ 0.5 m/s Operations for door weights ≤ 5 kg |
Holding force, typically | 750 N |
Holding force, guaranteed | 500 N |
Latching force, minimum | 30 N |
Latching force, maximum | 100 N |
Termination | Connector plug M12, 4-pole, (A-coding) |
Length of sensor | 40 mm |
Width of sensor | 40 mm |
Height of sensor | 179 mm |
Degree of protection | IP67 |
Ambient temperature | -25 ... +55 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Time to readiness, maximum | 4,000 ms |
Rated operating voltage | 26.5 ... 31.6 VDC (Protection against polarity reversal) |
AS-i Current consumption, maximum | 100 mA |
AS-i Specification | Safety-Slave |
AS-i Version | V 2.1 |
AS-i Profile | S-7.B.F.E |
AS-i, IO-Code | 0x7 |
AS-i, ID-Code | 0xB |
AS-i, ID-Code1 | 0xF |
AS-i, ID-Code2 | 0xE |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 | Solenoid control |
AS-i Outputs, DO 1 | For the variable setting of the latching force |
AS-i Outputs, DO 2 | For the variable setting of the latching force |
AS-i Outputs, DO 3 | For the variable setting of the latching force |
AS-i Parameter bits, P0 | Actuator in |
AS-i Parameter bits, P1 | Solenoid interlock locked |
AS-i Parameter bits, P2 | Auxiliary voltage in |
AS-i Parameter bits, P3 | Device error (fault detected) |
Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
Current consumption | 600 mA |
Rated operating voltage | 24 VDC |
Magnet switch-on time | 100 % |
Note (LED switching conditions display) | (1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 (2) LED yellow: Device condition (3) LED red: Internal device error |
PIN 1 | AS-i + |
PIN 2 | Aux - (P) |
PIN 3 | AS-Interface - |
PIN 4 | Aux + (P) |
Scope of delivery | Actuator must be ordered separately. |
Recommendation (actuator) | MZM 100-B1.1 |
Note (General) | Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
Note voltage AUX DC | stabilised PELV power supply |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.