Ex-Zone 1 and 21Resolution 14 and 30 mmProtected modeIntegrated contactor controlBeam coding
Product type description | EX-SLC440-ER-0650-30-H |
Article number (order number) | 103047639 |
EAN (European Article Number) | 4030661619194 |
eCl@ss number, version 12.0 | 27-27-27-04 |
eCl@ss number, version 11.0 | 27-27-27-04 |
eCl@ss number, version 9.0 | 27-27-27-04 |
ETIM number, version 7.0 | EC002549 |
ETIM number, version 6.0 | EC002549 |
| ATEX |
Explosion protection: regulations | EN IEC 60079-0 EN 60079-1 EN 60079-28 EN 60079-31 |
Explosion protection zones | 1 21 |
Explosion protection category | 2G 2D |
Explosion protection designation | D II 2G Ex db op is IIA T6 Gb D II 2D Ex op is tb IIIC T80°C Db |
Standards | EN IEC 61496-2 EN IEC 62061 EN ISO 13849-1 EN IEC 61496-1 |
Housing material | Shatterproof glass |
Reaction time, maximum | 10 ms |
Reaction time with beam coding A, maximum | 15 ms |
Restart interlock (manual reset) | Yes |
Contactor control integrated | Yes |
Beam coding available | Yes |
Blanking function | Yes |
7-segment display | Yes |
Integral system diagnostics, status | Yes |
Integral system diagnostics | Yes |
Number of fail-safe digital outputs | 2 |
Number of beams | 32 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 62061 |
Performance Level, up to | e |
Category | 4 |
PFH value | 5.14 x 10⁻⁹ /h |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Safety type in accordance with IEC 61496-1 | 4 |
Height of the protection field | 650 mm |
Range, protection field, minimum | 4 m |
Range, protection field, maximum | 20 m |
Wave length of the laserdiode | 850 nm |
Termination | Connector |
Terminal connector, Recipient | Connector plug M12, 8-pole |
Terminal, Connector, Transmitter | Connector plug M12, 4-pole |
Width of sensor | 100 mm |
Degree of protection | IP66 |
Ambient temperature | -25 ... +50 °C |
Storage and transport temperature | -25 ... +70 °C |
Switching voltage OSSD, HIGH signal | 24 V |
Output current, (fail-safe output), maximum | 0.25 A |
Design of control elements | short-circuit proof, p-type |
Scope of delivery | Kit with 2 mounting angles |
Recommended safety switchgear | SRB-E 301 |
Note (General) | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.