Door stop with magnetic latchingExplosion protection for ATEX Zones 2 and 22Thermoplastic enclosureRFID-technology for needs-based protection against tampering3 different directions of actuation
Product type description | EX-RSS16-D-R-10M-3G/D |
Article number (order number) | 103027193 |
EAN (European Article Number) | 4030661530581 |
eCl@ss number, version 12.0 | 27-27-46-01 |
eCl@ss number, version 11.0 | 27-27-24-03 |
eCl@ss number, version 9.0 | 27-27-24-03 |
ETIM number, version 7.0 | EC001829 |
ETIM number, version 6.0 | EC001829 |
| TÜV UKCA |
Explosion protection: regulations | EN IEC 60079-0 EN 60079-7 EN 60079-31 |
Explosion protection category | 3G 3D |
Explosion protection designation | D II 3D Ex tc IIIC T90°C Dc X |
Manufacturer declaration, zone | 2 22 |
Standards | EN IEC 60947-5-3 |
Coding | Universal coding |
Coding level according to EN ISO 14119 | Low |
Working principle | RFID |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Sensor topology | Sensor for series wiring |
Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Active area | Glass-fibre, reinforced thermoplastic |
Reaction time, maximum | 100 ms |
Duration of risk, maximum | 200 ms |
Gross weight | 250 g |
Latching magnet | Yes |
Diagnostic output | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Cascadable | Yes |
Integral system diagnostics, status | Yes |
Number of LEDs | 2 |
Number of semi-conductor outputs with signaling function | 1 |
Number of fail-safe digital outputs | 2 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 6.30 x 10⁻¹¹ /h |
PFD value | 1.50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Actuating panels | front side rear from head |
Active area | lateral front side cover-side |
Mounting | 2 x M5, Cylinder head screw |
Tightening torque of the fixing screws | 2 Nm |
Switch distance, typical | 15 mm |
Assured switching distance "ON" Sao | 5 mm |
Assured switching distance "OFF" Sar | 30 mm |
Hysteresis (Switching distance), maximum | 2 mm |
Repeat accuracy R | 0.5 mm |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Length of cable | 10 m |
Length of sensor | 91 mm |
Width of sensor | 52 mm |
Height of sensor | 30 mm |
Degree of protection | IP65 IP67 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, maximum | 93 % |
Note (Relative humidity) | non-condensing non-icing |
Restistance to shock | 30 g / 11 ms |
Permissible installation altitude above sea level, maximum | 2,000 m |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Operating voltage | 24 VDC -15 % / +10 % |
Operating current, minimum | 0.5 mA |
No-load supply current I0, typical | 100 mA |
Rated operating voltage | 24 VDC |
Operating current | 2,100 mA |
Required rated short-circuit current | 100 A |
Time to readiness, maximum | 2,000 ms |
Switching frequency, maximum | 1 Hz |
Utilisation category DC-12 | 24 VDC / 0.05 A |
Current consumption of the safety inputs | 5 mA |
Rated operating current (safety outputs) | 1,000 mA |
Output current, (fail-safe output), maximum | 1 A |
Design of control elements | p-type |
Voltage drop Ud, maximum | 1 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 1 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Operating current | 50 mA |
Design of control elements | p-type |
Voltage drop Ud, maximum | 2 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Interfering radiation | IEC 61000-6-4 |
Note (LED switching conditions display) | Multi-coloured LED: Green, Red LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
Scope of delivery | Actuator must be ordered separately. |
Recommendation (actuator) | RST16-1-R |
Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC SRB200EXi SRB101EXi |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.