alt
alt

Schmersal-AZM400Z-ST2-2P2P-BOW-E-DU-103047377
AZM400Z-ST2-2P2P-BOW-E-DU

Universal coding with RFID technology2 Connector M12, 8- and 5-polesGuard locking monitored2 Diagnostic outputsWith securing holes for Bowden cable assemblyElectric manual release with auxiliary voltage

  • Universal coding with RFID technology
  • 2 Connector M12, 8- and 5-poles
  • Guard locking monitored
  • 2 Diagnostic outputs
  • With securing holes for Bowden cable assembly
  • Electric manual release with auxiliary voltage

Ordering data

Note (Delivery capacity)

Not available!

Product type description

AZM400Z-ST2-2P2P-BOW-E-DU

Article number (order number)

103047377

EAN (European Article Number)

4030661618623

eCl@ss number, version 12.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 9.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

FCC

IC

UKCA

ANATEL

General data

Standards

EN ISO 13849-1

EN ISO 14119

EN IEC 60947-5-3

EN IEC 61508

Coding

Universal coding

Coding level according to EN ISO 14119

Low

Working principle

Magnetic field

RFID

Frequency band RFID

125 kHz

Transmitter output RFID, maximum

-6 dB/m

Housing material

Light alloy die-casting

Reaction time, maximum

100 ms

Reaction time, switching off safety outputs via actuator, maximum

100 ms

General data - Features

Solenoid interlock monitored

Yes

Electronic manual release

Yes

Short circuit detection

Yes

Cross-circuit detection

Yes

Securing holes for Bowden cable assembly

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of diagnostic signals

2

Number of safety contacts

2

Safety classification
Standards

EN ISO 13849-1

EN IEC 61508

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

1.00 x 10⁻⁹ /h

PFD value

9.00 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Safety classification - Guard locking function

Performance Level, up to

e

Category

4

PFH value

1.80 x 10⁻⁹ /h

PFD value

1.60 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Interlocking principle

bistable

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

Which have a lateral force Ftrans = 100 N: 100.000 operations

Allowed distance interlock to actuator, minimum

1 mm

Allowed distance interlock to actuator, maximum

7 mm

Angular misalignment between solenoid interlock and actuator, maximum

2 °

Minimum distance devices

30 mm

Holding force FZh in accordance with EN ISO 14119

10,000 N

Holding force Fmax, maximum

13,000 N

Lateral force at bolt return, maximal (against locked door)

300 N

Note (Lateral force at bolt return)

Does not apply to emergency exit, Bowden cable and manual release

Type of the fixing screws

2x M6

Note (Type of the fixing screws)

Property class min. 10.9

Tightening torque of the screw

8 Nm

Tightening torque of the fixing screws Bowden cable

1.2 Nm

Mechanical data - Connection technique

Termination

2 connector M12, 8 and 5 pin., both A-coded

Mechanical data - Dimensions

Length of sensor

46.7 mm

Width of sensor

77.8 mm

Height of sensor

166.7 mm

Ambient conditions

Degree of protection

IP66

IP67

Ambient temperature

-20 ... +55 °C

Storage and transport temperature

-40 ... +85 °C

Relative humidity, maximum

93 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibrations

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Permissible installation altitude above sea level, maximum

2,000 m

Ambient conditions - Insulation values

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution

3

Electrical data

Operating voltage

24 VDC -15 % / +10 % (stabilised PELV power supply)

Current consumption

100 mA

Current consumption, maximum

600 mA

Current consumption at 24V, minimum

10 mA

Current consumption at 24V, maximum

15 mA

No-load supply current I0, typical

100 mA

Operating current while bolt movement, peak

600 mA / 100 ms

Rated operating voltage

24 VDC

Operating current

50 mA

Required rated short-circuit current

100 A

External wire and device fuse rating

2 A gG

Time to readiness, maximum

1,500 ms

Switching frequency, approx.

0.3 Hz

Switching frequency, maximum

0.3 Hz

Open / close cycle (motor), minimum

3

Minimal average cycle time (with continuous operation)

20 s

Utilisation category DC-12

24 VDC / 0.05 A

Electrical fuse rating, maximum

2 A

Electrical data - Control inputs Guard locking function

Designation, Control inputs

E1 und E2 (p-schaltend), E3 (n-schaltend)

Switching thresholds of the control inputs

−3 V … 5 V (Low)

15 V … 30 V (High)

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Current consumption at 24V, minimum

5 mA

Current consumption at 24V, maximum

10 mA

Allowable discrepancy time (input), maximum

10 s

Test pulse interval, maximum

40 ms

Test pulse duration, maximum

5 ms

Permissible residual drive current

1.5 mA

Electrical data - Safety digital inputs

Classification ZVEI CB24I, Sink

C1

Electrical data - Safety digital outputs

Designation, Safety outputs

Y1 and Y2

Rated operating current (safety outputs)

250 mA

Design of control elements

short-circuit proof, p-type

Voltage drop Ud, maximum

2 V

Leakage current Ir, maximum

1.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Test pulse interval, typical

1000 ms

Test pulse duration, maximum

0.5 ms

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Diagnostic outputs

Design of control elements

short-circuit proof, p-type

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Note

The diagnostic output are not safety relevant outputs!

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

Connection

Connector 1

PIN 1

OUT2 Diagnostic output 2

PIN 2

E1 Control input 1

PIN 3

n.c.

PIN 4

Y1 Safety output 1

PIN 5

OUT1 Diagnostic output 1

PIN 6

E3 Control input 3

PIN 7

Y2 Safety output 2

PIN 8

E2 Control input 2

Connection

Connector 2

PIN 1

A1 Supply voltage UB

PIN 2

H2 GND

PIN 3

A2 GND

PIN 4

H1 Auxiliary voltage Uhe

PIN 5

FE (functional earth connection)

Scope of delivery

Scope of delivery

The actuator and the Bowden cable are not included in delivery.

Note: Versions AZM400Z-...-BOW may only be used in connection with Bowden cable release ACC-AZM400-BOW-.M-.M, which is available as an accessory. Use without the Bowden cable release fitted is not permissible.

Scope of delivery of mounting material

2 x M6 (10.9)

Accessory

Recommendation (actuator)

AZM400-B1

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

Schmersal-Report on Sustainability 2021/2022-1001761511
Schmersal
Schmersal-Explosion protection poster-1000718236
Schmersal
Schmersal-FLACHKABELKLEMME K 99-6431-00-02-101177831
Schmersal
Schmersal-SRB401EM115V-101183481
Schmersal
Schmersal-SRB401EM-230V-101182857
Schmersal
Schmersal-AZR 63 V2-1000341736
Schmersal
Schmersal-AZR 62A2-1000341734
Schmersal
Schmersal-AZR 600 EO-1000341732
Schmersal
Schmersal-AZR 32 V1-1000341653
Schmersal
Schmersal-AZM150SK-02/02RA-110-153032127
Schmersal
Schmersal-AZM150SK-02/02R-110-153032121
Schmersal
Schmersal-MZM 100 ST2-1P2P-A-DU-103047122
Schmersal