Repeated individual coding with RFID technologyCoding level "High" according to ISO 14119Connector M12, 8-polePower to unlockGuard locking monitoredDiagnostic outputHygienic designProtection class IP 69Suitable for mounting to profile systemsThermoplastic enclosureRFID-technology for needs-based protection against tampering3 different directions of actuationCompact design3 LEDs to show operating conditionsSuitable for hinged and sliding guardsSeries-wiringManual release
Note (Delivery capacity) | Not available! |
Product type description | AZM300Z-I2-ST-1P2P-DU |
Article number (order number) | 103044800 |
EAN (European Article Number) | 4030661563756 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| TÜV cULus ECOLAB FCC IC UKCA ANATEL |
Standards | EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Individual coding, multiple teaching |
Coding level according to EN ISO 14119 | High |
Working principle | RFID |
Frequency band RFID | 125 kHz |
Transmitter output RFID, maximum | -6 dB/m |
Housing material | Glass-fibre, reinforced thermoplastic |
Duration of risk, maximum | 200 ms |
Reaction time, switching off safety outputs via actuator, maximum | 100 ms |
Reaction time, switching off safety outputs via safety inputs, maximum | 1.5 ms |
Gross weight | 550 g |
Power to unlock | Yes |
Solenoid interlock monitored | Yes |
Latching | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of actuating directions | 3 |
Number of fail-safe digital outputs | 2 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 5.20 x 10⁻¹⁰ /h |
PFD value | 4.50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Performance Level, up to | d |
Category | 2 |
PFH value | 2.00 x 10⁻⁹ /h |
PFD value | 1.80 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 2 |
Mission time | 20 Year(s) |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) |
Angular misalignment between solenoid interlock and actuator, maximum | 2 ° |
Holding force FZh in accordance with EN ISO 14119 | 1,150 N |
Holding force Fmax, maximum | 1,500 N |
Latching force, adjustable, position 1 | 25 N |
Latching force, adjustable, position 2 | 50 N |
Type of the fixing screws | 2x M6 |
Tightening torque of the fixing screws, minimum | 6 Nm |
Tightening torque of the fixing screws, maximum | 7 Nm |
Switch distance, typical | 2 mm |
Assured switching distance "ON" Sao | 1 mm |
Assured switching distance "OFF" Sar | 20 mm |
Length of sensor chain, maximum | 200 m |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination | Connector M12, 8-pole, A-coded |
Length of sensor | 120 mm |
Width of sensor | 87.5 mm |
Height of sensor | 35 mm |
Degree of protection | IP66 IP67 IP69 |
Ambient temperature | +0 ... +60 °C |
Storage and transport temperature | -10 ... +90 °C |
Relative humidity, maximum | 93 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
No-load supply current I0, typical | 100 mA |
Current consumption with magnet ON, average | 200 mA |
Current consumption with magnet ON, peak | 350 mA / 200 ms |
Rated operating voltage | 24 VDC |
Operating current | 800 mA |
Required rated short-circuit current | 100 A |
External wire and device fuse rating | 2 A gG |
Time to readiness, maximum | 5,000 ms |
Switching frequency, maximum | 0.5 Hz |
Utilisation category DC-12 | 24 VDC / 0.05 A |
Electrical fuse rating, maximum | 2 A |
Designation, Magnet control | IN |
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 10 mA |
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 40 ms |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Designation, Safety inputs | X1 and X2 |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 5 mA |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 100 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Designation, Safety outputs | Y1 and Y2 |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 2 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.25 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Test pulse interval, typical | 1000 ms |
Test pulse duration, maximum | 0.5 ms |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Designation, Diagnostic outputs | OUT |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 2 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT Diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN Solenoid control |
Scope of delivery | Actuator must be ordered separately. |
Recommendation (actuator) | AZ/AZM300-B1 |
Note (General) | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.