Idle assignable pushbutton and LEDThermoplastic enclosureCoding in accordance to ISO 14119 by using RFID-Technology3 LEDs to show operating conditionsSensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontallySuitable for hinged and sliding guardsIntelligent diagnosisManual releaseProtection class IP66, IP67High holding force 20002 OSSD safety outputs for guard door monitoring2 OSSD safety outputs for guard locking monitoringsymmetrical construction form, assembly on 40mm profilesEmergency exit / Emergency release suitable for retrofitting
Note (Delivery capacity) | Not available! |
Product type description | AZM201D-ST-T-1P2P2P-2965-1-DU |
Article number (order number) | 103046770 |
EAN (European Article Number) | 4030661615776 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| TÜV cULus FCC IC UKCA ANATEL |
Standards | EN IEC 62061 EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Universal coding |
Coding level according to EN ISO 14119 | Low |
Working principle | RFID |
Frequency band RFID | 125 kHz |
Transmitter output RFID, maximum | -6 dB/m |
Housing material | Glass-fibre, reinforced thermoplastic |
Duration of risk, maximum | 200 ms |
Reaction time, switching off safety outputs via actuator, maximum | 100 ms |
Reaction time, switching off safety outputs via safety inputs, maximum | 0.5 ms |
Power to unlock | Yes |
Actuator monitored | Yes |
Solenoid interlock monitored | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of safety contacts | 4 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 5.70 x 10⁻¹⁰ /h |
PFD value | 5.00 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Safety classification - Interlocking function 2 |
Performance Level, up to | d |
Category | 3 |
Safety Integrity Level (SIL), suitable for applications in | 2 |
Mission time | 20 Year(s) |
Mission time | 20 Year(s) |
Mechanical life, minimum | 1,000,000 Operations |
Holding force FZh in accordance with EN ISO 14119 | 2,000 N |
Note (clamping force FZh) | 1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Holding force Fmax, maximum | 2,600 N |
Note (clamping force Fmax) | 1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Latching force | 30 N |
Actuating speed, maximum | 0.2 m/s |
Type of the fixing screws | 2x M6 |
Tightening torque of the fastening screws for the housing cover, minimum | 0.7 Nm |
Tightening torque of the fastening screws for the housing cover, maximum | 1 Nm |
Note | Torx T10 |
Length of sensor chain, maximum | 200 m |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination | Connector M23, 12-pole |
Length of sensor | 50 mm |
Width of sensor | 40 mm |
Height of sensor | 220 mm |
Degree of protection | IP66 IP67 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
No-load supply current I0, typical | 50 mA |
Current consumption with magnet ON, peak | 700 mA / 100 ms |
Rated operating voltage | 24 VDC |
Operating current | 1,200 mA |
Required rated short-circuit current | 100 A |
Time to readiness, maximum | 4,000 ms |
Switching frequency, approx. | 1 Hz |
Switching frequency, maximum | 1 Hz |
Electrical fuse rating, maximum | 3 A |
Designation, Magnet control | IN |
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 40 ms |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 100 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Designation, Safety outputs | Y1 and Y2 |
Rated operating current (safety outputs) | 250 mA |
Voltage drop Ud, maximum | 4 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Note, Utilisation category DC-13 | Gilt für die Ausgänge Y1 und Y2 |
Test pulse interval, typical | 1000 ms |
Test pulse duration, maximum | 0.5 ms |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Operating current | 50 mA |
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
PIN 1 | A1 Supply voltage UB |
PIN 2 | OUT diagnostic output |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | Y3 safety output 3 |
PIN 6 | Y4 safety output Y4 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN Solenoid control |
PIN 9 | white LED |
PIN 10 | Key button |
PIN 11 | Key button |
PIN 12 | Not used |
Scope of delivery | Actuator must be ordered separately. Triangular key for AZM 201 |
Recommendation (actuator) | AZ/AZM201-B1 AZ/AZM201-B30 |
Note (General) | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
Note (Actuator monitored) | Safety outputs Y1, Y2 |
Note (Solenoid interlock monitored) | Safety outputs Y3, Y4 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.