Actuator monitoredPower to lockThermoplastic enclosureMax. length of the sensor chain 200 mSelf-monitoring series-wiringCoding in accordance to ISO 14119 by using RFID-Technology3 LEDs to show operating conditionsSensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontallySuitable for hinged and sliding guardsIntelligent diagnosisManual releaseProtection class IP66, IP67High holding force 2000symmetrical construction form, assembly on 40mm profilesOSSD safety outputsEmergency exit / Emergency release suitable for retrofitting
Note (Delivery capacity) | Not available! |
Product type description | AZM201B-ST2-T-1P2PW-A-DU |
Article number (order number) | 103046730 |
EAN (European Article Number) | 4030661569024 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| TÜV cULus FCC IC UKCA ANATEL |
Standards | EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-3 EN IEC 61508 |
Coding | Universal coding |
Coding level according to EN ISO 14119 | Low |
Working principle | RFID |
Frequency band RFID | 125 kHz |
Transmitter output RFID, maximum | -6 dB/m |
Housing material | Glass-fibre, reinforced thermoplastic |
Duration of risk, maximum | 200 ms |
Reaction time, switching off safety outputs via actuator, maximum | 100 ms |
Reaction time, switching off safety outputs via safety inputs, maximum | 1.5 ms |
Gross weight | 570 g |
Power to lock | Yes |
Actuator monitored | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of safety contacts | 2 |
Safety classification |
Standards | EN ISO 13849-1 EN IEC 61508 |
Performance Level, up to | e |
Category | 4 |
PFH value | 1.90 x 10⁻⁹ /h |
PFD value | 1.60 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical life, minimum | 1,000,000 Operations |
Holding force FZh in accordance with EN ISO 14119 | 2,000 N |
Note (clamping force FZh) | 1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Holding force Fmax, maximum | 2,600 N |
Note (clamping force Fmax) | 1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Latching force | 30 N |
Actuating speed, maximum | 0.2 m/s |
Type of the fixing screws | 2x M6 |
Tightening torque of the fixing screws, maximum | 8 Nm |
Tightening torque of the fastening screws for the housing cover, minimum | 0.7 Nm |
Tightening torque of the fastening screws for the housing cover, maximum | 1 Nm |
Note | Torx T10 |
Length of sensor chain, maximum | 200 m |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination | Connector M12, 8-pole |
Length of sensor | 50 mm |
Width of sensor | 40 mm |
Height of sensor | 220 mm |
Degree of protection | IP66 IP67 |
Ambient temperature | -25 ... +60 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, maximum | 93 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibrations | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Operating voltage | 24 VDC -15 % / +10 % (stabilised PELV power supply) |
No-load supply current I0, typical | 50 mA |
Current consumption with magnet ON, average | 200 mA |
Current consumption with magnet ON, peak | 700 mA / 100 ms |
Rated operating voltage | 24 VDC |
Operating current | 1,200 mA |
Required rated short-circuit current | 100 A |
External wire and device fuse rating | 2 A gG |
Time to readiness, maximum | 4,000 ms |
Switching frequency, maximum | 1 Hz |
Electrical fuse rating, maximum | 2 A |
Designation, Magnet control | IN |
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 10 mA |
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 40 ms |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Designation, Safety inputs | X1 and X2 |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 5 mA |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 100 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Designation, Safety outputs | Y1 and Y2 |
Rated operating current (safety outputs) | 250 mA |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 2 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Test pulse interval, typical | 1000 ms |
Test pulse duration, maximum | 0.5 ms |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Designation, Diagnostic outputs | OUT |
Operating current | 50 mA |
Design of control elements | short-circuit proof, p-type |
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT Diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN Solenoid control |
Scope of delivery | Actuator must be ordered separately. Triangular key for AZM 201 |
Recommendation (actuator) | AZ/AZM201-B1 AZ/AZM201-B30 |
Note (General) | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.