Guard locking monitoredserial diagnostic outputThermoplastic enclosureElectronic contact-free, coded systemMax. length of the sensor chain 200 mSelf-monitoring series-wiring3 LEDs to show operating conditionsSensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontallyIntelligent diagnosisManual release
Note (Delivery capacity) | Not available! |
Product type description | AZM 200CC-T-SD2PA |
Article number (order number) | 101193281 |
EAN (European Article Number) | 4030661443256 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| TÜV cULus |
Standards | EN ISO 13849-1 EN IEC 60947-5-1 EN IEC 61508 |
Working principle | inductive |
Housing material | Glass-fibre, reinforced thermoplastic |
Reaction time, maximum | 60 ms |
Duration of risk, maximum | 120 ms |
Power to lock | Yes |
Solenoid interlock monitored | Yes |
Serial diagnostics | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of safety contacts | 2 |
Number of series-wiring of sensors | 31 |
Safety classification |
Standards | EN IEC 60947-5-3 EN IEC 61508 |
Mission time | 20 Year(s) |
Performance Level, up to | e |
Category | 4 |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mechanical life, minimum | 1,000,000 Operations |
Holding force FZh in accordance with EN ISO 14119 | 2,000 N |
Note (clamping force FZh) | 1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Holding force Fmax, maximum | 2,600 N |
Note (clamping force Fmax) | 1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use. |
Latching force | 30 N |
Actuating speed, maximum | 0.2 m/s |
Tightening torque of the fastening screws for the housing cover, minimum | 0.7 Nm |
Tightening torque of the fastening screws for the housing cover, maximum | 1 Nm |
Note | Torx T10 |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Termination | Spring pulley connection |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 1.5 mm² |
Note | All indications including the conductor ferrules. |
Wire cross-section, minimum | 23 AWG |
Wire cross-section, maximum | 15 AWG |
Wire cross-section | 23 ... 15 AWG |
Allowed type of cable | solid single-wire solid multi-wire flexible |
Length of sensor | 50 mm |
Width of sensor | 40 mm |
Height of sensor | 220 mm |
Degree of protection | IP67 |
Ambient temperature | -25 ... +50 °C |
Storage and transport temperature | -25 ... +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Resistance to vibrations | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | II |
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution | 3 |
Operating voltage | 24 VDC -15 % / +10 % |
No-load supply current I0, typical | 600 mA |
Rated operating voltage | 24 VDC |
Operating current | 1,200 mA |
Time to readiness, maximum | 4,000 ms |
Switching frequency, approx. | 1 Hz |
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time | 100 % |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24 V | 5 mA |
Rated operating current (safety outputs) | 250 mA |
Voltage drop Ud, maximum | 4 V |
Leakage current Ir, maximum | 0.5 mA |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Designation, Serial diagnostic SD | OUT |
Operation current | 150 mA |
Design of control elements | short-circuit proof, p-type |
Wiring capacitance | 50 nF |
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Scope of delivery | Actuator must be ordered separately. Triangular key for AZM 200 |
Recommendation (actuator) | AZ/AZM 200-B1 |
Note (General) | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.