Large wiring compartmentManual release, rearcable entries 4 M 16 x 1.5Thermoplastic enclosureDouble-insulatedInterlock with protection against incorrect locking.130 mm x 90 mm x 30 mm6 ContactsLong life
Note (Delivery capacity) | Not available! |
Product type description | AZM 161CC-12/12RKEU -110/230 |
Article number (order number) | 101187920 |
EAN (European Article Number) | 4030661357218 |
eCl@ss number, version 12.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 9.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
| IFA cULus CCC UKCA |
Standards | EN ISO 13849-1 EN ISO 14119 EN IEC 60947-5-1 |
Coding level according to EN ISO 14119 | Low |
Working principle | electromechanical |
Housing material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Gross weight | 445 g |
Power to unlock | Yes |
Manual release | Yes |
Number of actuating directions | 3 |
Number of auxiliary contacts | 2 |
Number of safety contacts | 4 |
Safety classification |
Standards | EN ISO 13849-1 |
Performance Level, up to | c |
Category | 1 |
B10D Normally-closed contact (NC) | 2,000,000 Operations |
Note | Electrical life on request. |
B10D Normally-open contact (NO) | 1,000,000 Operations |
Note | at 10% Ie and ohmic load |
Mission time | 20 Year(s) |
Safety classification - Fault exclusion |
Please note: | Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed. |
Performance Level, up to | d |
Category | 3 |
Note | for 2-channel use and with suitable logic unit. |
Mission time | 20 Year(s) |
Performance Level, up to | e |
Note (Performance Level) | Information for the safety classification of the guard locking function is documented in the "Operating instructions" or in the "Operation and mounting" instructions. |
Mechanical life, minimum | 1,000,000 Operations |
Actuating play in direction of actuation | 5.5 mm |
Holding force FZh in accordance with EN ISO 14119 | 2,000 N |
Holding force Fmax, maximum | 2,600 N |
Latching force | 30 N |
Positive break travel | 10 mm |
Positive break force per NC contact, minimum | 10 N |
Positive break force, minimum | 20 N |
Actuating speed, maximum | 2 m/s |
Mounting | Screws |
Type of the fixing screws | 3x M5 |
Type of the screw head | Flat head screw |
Tightening torque of the fastening screws for the housing cover | 0.6 Nm |
Note | The tightening sequence of the cover screws must be observed. This can be found in the attached drawing in the “Pictures” tab. |
Cable entry | 4 x M16 x 1,5 |
Termination | Cage clamps |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 1.5 mm² |
Note | All indications including the conductor ferrules. |
Allowed type of cable | solid single-wire solid multi-wire flexible |
Length of sensor | 30 mm |
Width of sensor | 130 mm |
Height of sensor | 90 mm |
Degree of protection | IP67 |
Ambient temperature | -30 ... +60 °C |
Storage and transport temperature | -30 ... +85 °C |
Note (Relative humidity) | non-condensing non-icing |
Protection class | II |
Permissible installation altitude above sea level, maximum | 2,000 m |
Rated insulation voltage Ui | 250 VAC |
Rated impulse withstand voltage Uimp | 4 kV |
Thermal test current | 6 A |
Rated control voltage | 110 VAC 230 VAC |
Required rated short-circuit current | 1,000 A |
Electrical power consumption, maximum | 10 W |
Switching element | NO contact, NC contact |
Switching principle | Slow action |
Maximum switching frequency | 1,000 /h |
Material of the contacts, electrical | Silver |
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 50 ms |
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 2.5 A |
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 4 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 2.5 A |
Note (applications) | sliding safety guard removable guard hinged safety guard |
Scope of delivery | Actuator must be ordered separately. |
Note (Manual release) | For maintenance, installation, etc. For manual release using M5 triangular key, available as accessory Top-side (ordering suffix -ED) or rear-side (ordering suffix -EU) mounting possible |
Note (Emergency exit, Manual release) | A combination of manual release and emergency exit in different mounting directions in only possible for the following variants: -ED/-TU and -TD/-EU |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.