alt
alt

TM-2-8292/IVS
225336 TM-2-8292/IVS
225336

ON-OFF switches, TM, 10 A, service distribution board mounting, 2 contact unit(s), Contacts: 3, 90 °, maintained, With 0 (Off) position, 0-1, Design number 8292On-Off switch, Product range: Control switches, Part group reference: TM, with black thumb grip and front plate, Contacts: 3, Degree of Protection: Front IP30, Design: service distribution board mounting, Switching angle: 90 °, Switching performance: maintained, With 0 (Off) position, front plate: 0-1, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 3 kW, Rated uninterrupted current: Iu = 10 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, CSA, UL, Control switch as per IEC/EN 60947-5-1, Auxiliary switch as per IEC/EN 60947-5-1

ON-OFF switches, TM, 10 A, service distribution board mounting, 2 contact unit(s), Contacts: 3, 90 °, maintained, With 0 (Off) position, 0-1, Design number 8292
On-Off switch, Product range: Control switches, Part group reference: TM, with black thumb grip and front plate, Contacts: 3, Degree of Protection: Front IP30, Design: service distribution board mounting, Switching angle: 90 °, Switching performance: maintained, With 0 (Off) position, front plate: 0-1, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 3 kW, Rated uninterrupted current: Iu = 10 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, CSA, UL, Control switch as per IEC/EN 60947-5-1, Auxiliary switch as per IEC/EN 60947-5-1

Product range Control switches
Part group reference TM
Basic function ON-OFF switches
Contacts with black thumb grip and front plate
Degree of Protection 3
Design Front IP30
Contact sequence service distribution board mounting
Switching angle 000Z082
Switching performance 115S009-2
Design number 90 °
Front plate no. maintained
With 0 (Off) position
front plate 8292
400 V [P] 115K208
Rated uninterrupted current [Iu] 0-1
Note on rated uninterrupted current !u 3 kW
Number of contact units 10 A
Standards Rated uninterrupted current Iu is specified for max. cross-section.
Climatic proofing 2 contact unit(s)
Ambient temperature
>Open
IEC/EN 60947, VDE 0660, CSA, UL
Control switch as per IEC/EN 60947-5-1
Auxiliary switch as per IEC/EN 60947-5-1
Overvoltage category/pollution degree Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Rated impulse withstand voltage [Uimp] -25 - +50 °C
Mounting position III/3
Electrical characteristics
>Rated operational voltage [Ue]
4000 V AC
Electrical characteristics
>Rated uninterrupted current [Iu]
As required
Electrical characteristics
>Note on rated uninterrupted current !u
500 V AC
Short-circuit rating
>Fuse
10 A
Safe isolation to EN 61140
>Current heat loss per contact at Ie
Rated uninterrupted current Iu is specified for max. cross-section.
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
10 A gG/gL
Lifespan, mechanical [Operations] 0.15 W
Maximum operating frequency [Operations/h] 0.15 CO
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
> 1 x 106
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 1200
Solid or stranded 3 kW
Flexible with ferrules to DIN 46228 < 10 -5, < 1 fault in 100000 operations HF
Flexible 1 x 1,5
2 x 1,5 mm2
Terminal screw 1 x 1.0
2 x 1.0 mm2
Tightening torque for terminal screw 1 x 1.5
2 x 1.5 mm2
Contacts
>Rated operational voltage [Ue]
M2.5
Contacts
>Rated uninterrupted current max.
>Main conducting paths
>General use
0.4 Nm
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>General Use [IU]
300 V AC
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>Pilot Duty
10 A
Switching capacity
>Maximum motor rating
>Single-phase
>120 V AC
10 A
Switching capacity
>Maximum motor rating
>Single-phase
>240 V AC
A 300
Switching capacity
>Maximum motor rating
>Single-phase
>277 V AC
0.33 HP
Switching capacity
>Maximum motor rating
>Three-phase
>120 V AC
0.75 HP
Switching capacity
>Maximum motor rating
>Three-phase
>240 V AC
0.75 HP
Terminal capacity
>Solid or flexible conductor with ferrule
0.75 HP
Terminal capacity
>Terminal screw
1 HP
Terminal capacity
>Tightening torque
14 AWG
Rated operational current for specified heat dissipation [In] M2.5
Heat dissipation per pole, current-dependent [Pvid] 3.5 lb-in
Equipment heat dissipation, current-dependent [Pvid] 10 A
Static heat dissipation, non-current-dependent [Pvs] 0.15 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+50 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Version as main switch Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Version as maintenance-/service switch The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Version as safety switch No
Version as emergency stop installation No
Version as reversing switch No
Number of switches No
Max. rated operation voltage Ue AC No
Rated operating voltage 1
Rated permanent current Iu 500 V
Rated permanent current at AC-23, 400 V 500 - 500 V
Rated permanent current at AC-21, 400 V 10 A
Rated operation power at AC-3, 400 V A
Rated short-time withstand current lcw 0 A
Rated operation power at AC-23, 400 V 0 kW
Switching power at 400 V 0 kA
Conditioned rated short-circuit current Iq 0 kW
Number of poles 0 kW
Number of auxiliary contacts as normally closed contact 0 kA
Number of auxiliary contacts as normally open contact 3
Number of auxiliary contacts as change-over contact 0
Motor drive optional 0
Motor drive integrated 0
Voltage release optional No
Device construction No
Suitable for ground mounting No
Suitable for front mounting 4-hole Built-in device fixed built-in technique
Suitable for front mounting centre Yes
Suitable for distribution board installation No
Suitable for intermediate mounting No
Colour control element Yes
Type of control element No
Interlockable Black
Type of electrical connection of main circuit Toggle
Degree of protection (IP), front side No
Degree of protection (NEMA) Screw connection
Product Standards IP30
UL File No. Other
UL Category Control No. UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
CSA File No. E36332
North America Certification NLRV
Degree of Protection UL report applies to both US and Canada

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton