T5B-2-1/I4/SVB
222924 T5B-2-1/I4/SVB
222924

Main switch, T5B, 63 A, surface mounting, 2 contact unit(s), 3 pole, Emergency switching off function, With red rotary handle and yellow locking ringMain switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T5B, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, 3 pole, Degree of Protection: IP65, Design: surface mounting, Switching angle: 90 °, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 30 kW, Rated uninterrupted current: Iu = 63 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

Main switch, T5B, 63 A, surface mounting, 2 contact unit(s), 3 pole, Emergency switching off function, With red rotary handle and yellow locking ring
Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: T5B, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, 3 pole, Degree of Protection: IP65, Design: surface mounting, Switching angle: 90 °, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 30 kW, Rated uninterrupted current: Iu = 63 A, 2 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

Product range Main switch
maintenance switch
Repair switch
Part group reference T5B
Stop Function Emergency switching off function
Number of poles With red rotary handle and yellow locking ring
Degree of Protection 3 pole
Design IP65
Contact sequence 000Z083
Switching angle surface mounting
Design number 000Z428
Function 115S009-2
400 V [P] 90 °
Rated uninterrupted current [Iu] 1
Note on rated uninterrupted current !u 1150SPC-194
Number of contact units 30 kW
Standards 63 A
Climatic proofing Rated uninterrupted current Iu is specified for max. cross-section.
Ambient temperature
>Enclosed
2 contact unit(s)
Overvoltage category/pollution degree IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnector according to IEC/EN 60947-3
Rated impulse withstand voltage [Uimp] Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance -25 - +40 °C
Mounting position III/3
Mechanical variables
>Number of poles
6000 V AC
Electrical characteristics
>Rated operational voltage [Ue]
15 g
Electrical characteristics
>Rated uninterrupted current [Iu]
As required
Electrical characteristics
>Note on rated uninterrupted current !u
3 pole
Load rating with intermittent operation, class 12
>AB 25 % DF
690 V AC
Load rating with intermittent operation, class 12
>AB 40 % DF
63 A
Load rating with intermittent operation, class 12
>AB 60 % DF
Rated uninterrupted current Iu is specified for max. cross-section.
Short-circuit rating
>Fuse
2 x Ie
Rated short-time withstand current (1 s current) [Icw ] 1.6 x Ie
Note on rated short-time withstand current lcw 1.3 x Ie
Rated conditional short-circuit current [Iq] 80 A gG/gL
cos ϕ rated making capacity as per IEC 60947-3 1300 Arms
Rated breaking capacity cos ϕ to IEC 60947-3
>230 V
Current for a time of 1 second
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
2 kA
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
800 A
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
520 A
Safe isolation to EN 61140
>between the contacts
600 A
Safe isolation to EN 61140
>Current heat loss per contact at Ie
480 A
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
340 A
Lifespan, mechanical [Operations] 440 V AC
Maximum operating frequency [Operations/h] 4.5 W
AC
>AC-3
>Rating, motor load switch [P]
>220 V 230 V [P]
4.5 CO
AC
>AC-3
>Rating, motor load switch [P]
>230 V Star-delta [P]
> 0.5 x 106
AC
>AC-3
>Rating, motor load switch [P]
>400 V 415 V [P]
1200
AC
>AC-3
>Rating, motor load switch [P]
>400 V Star-delta [P]
15 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V [P]
18.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V Star-delta [P]
22 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V [P]
30 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V Star-delta [P]
22 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V [Ie]
37 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V star-delta [Ie]
15 kW
AC
>AC-3
>Rated operational current motor load switch
>400V 415 V [Ie]
22 kW
AC
>AC-3
>Rated operational current motor load switch
>400 V star-delta [Ie]
51 A
AC
>AC-3
>Rated operational current motor load switch
>500 V [Ie ]
63 A
AC
>AC-3
>Rated operational current motor load switch
>500 V star-delta [Ie ]
41 A
AC
>AC-3
>Rated operational current motor load switch
>690 V [Ie]
63 A
AC
>AC-3
>Rated operational current motor load switch
>690 V star-delta [Ie]
33 A
AC
>AC-21A
>Rated operational current switch
>440 V [Ie]
57.2 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>230 V [P]
17 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
29.4 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
63 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
18.5 kW
AC
>AC-23A
>Rated operational current motor load switch
>230 V [Ie]
30 kW
AC
>AC-23A
>Rated operational current motor load switch
>400 V 415 V [Ie]
22 kW
AC
>AC-23A
>Rated operational current motor load switch
>500 V [Ie]
22 kW
AC
>AC-23A
>Rated operational current motor load switch
>690 V [Ie]
63 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Rated operational current [Ie]
63 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Voltage per contact pair in series
33 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Rated operational current [Ie]
23.8 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Contacts
63 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Rated operational current [Ie]
60 V
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Contacts
50 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Rated operational current [Ie]
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Contacts
50 A
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Rated operational current [Ie]
2 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Contacts
50 A
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Rated operational current [Ie]
3 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Contacts
25 A
DC
>DC-13, Control switches L/R = 50 ms
>Rated operational current [Ie]
3 Quantity
DC
>DC-13, Control switches L/R = 50 ms
>Voltage per contact pair in series
20 A
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 6 Quantity
Solid or stranded 25 A
Flexible with ferrules to DIN 46228 24 V
Terminal screw < 10 -5, < 1 fault in 100000 operations HF
Tightening torque for terminal screw 1 x (2,5 - 35)
2 x (2,5 - 16) mm2
Notes 1 x (1 - 25)
2 x (1.5 - 10) mm2
Contacts
>Rated operational voltage [Ue]
M6
Contacts
>Rated uninterrupted current max.
>Main conducting paths
>General use
4 Nm
Switching capacity
>Maximum motor rating
>Single-phase
>120 V AC
B10d values as per EN ISO 13849-1, table C1
Switching capacity
>Maximum motor rating
>Single-phase
>200 V AC
600 V AC
Switching capacity
>Maximum motor rating
>Single-phase
>240 V AC
63 A
Switching capacity
>Maximum motor rating
>Three-phase
>200 V AC
3 HP
Switching capacity
>Maximum motor rating
>Three-phase
>240 V AC
7.5 HP
Switching capacity
>Maximum motor rating
>Three-phase
>480 V AC
10 HP
Switching capacity
>Maximum motor rating
>Three-phase
>600 V AC
15 HP
Short Circuit Current Rating
>High fault rating
15 HP
Short Circuit Current Rating
>max. Fuse
40 HP
Terminal capacity
>Solid or flexible conductor with ferrule
40 HP
Terminal capacity
>Terminal screw
10 kA
Terminal capacity
>Tightening torque
100, Class J A
Rated operational current for specified heat dissipation [In] 12 - 4 AWG
Heat dissipation per pole, current-dependent [Pvid] M6
Equipment heat dissipation, current-dependent [Pvid] 35.4 lb-in
Static heat dissipation, non-current-dependent [Pvs] 63 A
Heat dissipation capacity [Pdiss] 4.5 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
-25 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
+40 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
UV resistance only in connection with protective shield.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Version as main switch Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Version as maintenance-/service switch Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Version as safety switch The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Version as emergency stop installation Yes
Version as reversing switch Yes
Number of switches No
Max. rated operation voltage Ue AC Yes
Rated operating voltage No
Rated permanent current Iu 1
Rated permanent current at AC-23, 400 V 690 V
Rated permanent current at AC-21, 400 V 690 - 690 V
Rated operation power at AC-3, 400 V 63 A
Rated short-time withstand current lcw 63 A
Rated operation power at AC-23, 400 V 63 A
Switching power at 400 V 22 kW
Conditioned rated short-circuit current Iq 1.3 kA
Number of poles 30 kW
Number of auxiliary contacts as normally closed contact 30 kW
Number of auxiliary contacts as normally open contact 2 kA
Number of auxiliary contacts as change-over contact 3
Motor drive optional 0
Motor drive integrated 0
Voltage release optional 0
Device construction No
Suitable for ground mounting No
Suitable for front mounting 4-hole No
Suitable for front mounting centre Complete device in housing
Suitable for distribution board installation Yes
Suitable for intermediate mounting No
Colour control element No
Type of control element No
Interlockable No
Type of electrical connection of main circuit Red
Degree of protection (IP), front side Door coupling rotary drive
Degree of protection (NEMA) Yes
Product Standards Screw connection
UL File No. IP65
UL Category Control No. 12
CSA File No. UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
CSA Class No. E36332
North America Certification NLRV
Specially designed for North America 12528
Suitable for 3211-07
Degree of Protection UL listed, CSA certified

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton