T0-8-8364/E
016141 T0-8-8364/E
016141

Changeoverswitches, T0, 20 A, flush mounting, 8 contact unit(s), Contacts: 16, 60 °, maintained, With 0 (Off) position, 1-0-2, Design number 8364Changeover switch, Product range: Control switches, Part group reference: T0, with black thumb grip and front plate, Contacts: 16, Degree of Protection: Front IP65, Design: flush mounting, Switching angle: 60 °, Switching performance: maintained, With 0 (Off) position, front plate: 1-0-2, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 5.5 kW, Rated uninterrupted current: Iu = 20 A, 8 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

Changeoverswitches, T0, 20 A, flush mounting, 8 contact unit(s), Contacts: 16, 60 °, maintained, With 0 (Off) position, 1-0-2, Design number 8364
Changeover switch, Product range: Control switches, Part group reference: T0, with black thumb grip and front plate, Contacts: 16, Degree of Protection: Front IP65, Design: flush mounting, Switching angle: 60 °, Switching performance: maintained, With 0 (Off) position, front plate: 1-0-2, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 5.5 kW, Rated uninterrupted current: Iu = 20 A, 8 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

Product range Control switches
Part group reference T0
Basic function Changeoverswitches
Contacts with black thumb grip and front plate
Degree of Protection 16
Design Front IP65
Contact sequence flush mounting
Switching angle 000Z079
Switching performance 1150SWI-97
Design number 60 °
Front plate no. maintained
With 0 (Off) position
front plate 8364
400 V [P] 115K003
Rated uninterrupted current [Iu] 1-0-2
Note on rated uninterrupted current !u 5.5 kW
Number of contact units 20 A
Standards Rated uninterrupted current Iu is specified for max. cross-section.
Climatic proofing 8 contact unit(s)
Ambient temperature
>Open
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnector according to IEC/EN 60947-3
Ambient temperature
>Enclosed
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Overvoltage category/pollution degree -25 - +50 °C
Rated impulse withstand voltage [Uimp] -25 - +40 °C
Mechanical shock resistance III/3
Mounting position 6000 V AC
Electrical characteristics
>Rated operational voltage [Ue]
15 g
Electrical characteristics
>Rated uninterrupted current [Iu]
As required
Electrical characteristics
>Note on rated uninterrupted current !u
690 V AC
Load rating with intermittent operation, class 12
>AB 25 % DF
20 A
Load rating with intermittent operation, class 12
>AB 40 % DF
Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
>AB 60 % DF
2 x Ie
Short-circuit rating
>Fuse
1.6 x Ie
Rated short-time withstand current (1 s current) [Icw ] 1.3 x Ie
Note on rated short-time withstand current lcw 20 A gG/gL
Rated conditional short-circuit current [Iq] 320 Arms
cos ϕ rated making capacity as per IEC 60947-3 Current for a time of 1 second
Rated breaking capacity cos ϕ to IEC 60947-3
>230 V
6 kA
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
130 A
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
100 A
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
110 A
Safe isolation to EN 61140
>between the contacts
80 A
Safe isolation to EN 61140
>Current heat loss per contact at Ie
60 A
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
440 V AC
Lifespan, mechanical [Operations] 0.6 W
Maximum operating frequency [Operations/h] 0.6 CO
AC
>AC-3
>Rating, motor load switch [P]
>220 V 230 V [P]
> 0.4 x 106
AC
>AC-3
>Rating, motor load switch [P]
>230 V Star-delta [P]
1200
AC
>AC-3
>Rating, motor load switch [P]
>400 V 415 V [P]
3 kW
AC
>AC-3
>Rating, motor load switch [P]
>400 V Star-delta [P]
5.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V [P]
5.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V Star-delta [P]
7.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V [P]
5.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V Star-delta [P]
7.5 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V [Ie]
4 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V star-delta [Ie]
5.5 kW
AC
>AC-3
>Rated operational current motor load switch
>400V 415 V [Ie]
11.5 A
AC
>AC-3
>Rated operational current motor load switch
>400 V star-delta [Ie]
20 A
AC
>AC-3
>Rated operational current motor load switch
>500 V [Ie ]
11.5 A
AC
>AC-3
>Rated operational current motor load switch
>500 V star-delta [Ie ]
20 A
AC
>AC-3
>Rated operational current motor load switch
>690 V [Ie]
9 A
AC
>AC-3
>Rated operational current motor load switch
>690 V star-delta [Ie]
15.6 A
AC
>AC-21A
>Rated operational current switch
>440 V [Ie]
4.9 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>230 V [P]
8.5 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
20 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
3 kW
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
5.5 kW
AC
>AC-23A
>Rated operational current motor load switch
>230 V [Ie]
7.5 kW
AC
>AC-23A
>Rated operational current motor load switch
>400 V 415 V [Ie]
5.5 kW
AC
>AC-23A
>Rated operational current motor load switch
>500 V [Ie]
13.3 A
AC
>AC-23A
>Rated operational current motor load switch
>690 V [Ie]
13.3 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Rated operational current [Ie]
13.3 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Voltage per contact pair in series
7.6 A
DC
>DC-21A [Ie ]
>Rated operational current [Ie]
10 A
DC
>DC-21A [Ie ]
>Contacts
60 V
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Rated operational current [Ie]
1 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Contacts
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Rated operational current [Ie]
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Contacts
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Rated operational current [Ie]
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Contacts
2 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Rated operational current [Ie]
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Contacts
3 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Rated operational current [Ie]
5 A
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Contacts
3 Quantity
DC
>DC-13, Control switches L/R = 50 ms
>Rated operational current [Ie]
5 A
DC
>DC-13, Control switches L/R = 50 ms
>Voltage per contact pair in series
5 Quantity
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 10 A
Solid or stranded 32 V
Flexible with ferrules to DIN 46228 < 10 -5, < 1 fault in 100000 operations HF
Terminal screw 1 x (1 - 2,5)
2 x (1 - 2,5) mm2
Tightening torque for terminal screw 1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Notes M3.5
Contacts
>Rated operational voltage [Ue]
1 Nm
Contacts
>Rated uninterrupted current max.
>Main conducting paths
>General use
B10d values as per EN ISO 13849-1, table C1
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>General Use [IU]
600 V AC
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>Pilot Duty
16 A
Switching capacity
>Maximum motor rating
>Single-phase
>120 V AC
10 A
Switching capacity
>Maximum motor rating
>Single-phase
>200 V AC
A 600
P 600
Switching capacity
>Maximum motor rating
>Single-phase
>240 V AC
0.5 HP
Switching capacity
>Maximum motor rating
>Three-phase
>200 V AC
1 HP
Switching capacity
>Maximum motor rating
>Three-phase
>240 V AC
1.5 HP
Switching capacity
>Maximum motor rating
>Three-phase
>480 V AC
3 HP
Switching capacity
>Maximum motor rating
>Three-phase
>600 V AC
3 HP
Short Circuit Current Rating
>Basic Rating
7.5 HP
Short Circuit Current Rating
>max. Fuse
7.5 HP
Short Circuit Current Rating
>High fault rating
5 kA
Short Circuit Current Rating
>max. Fuse
50 A
Terminal capacity
>Solid or flexible conductor with ferrule
10 kA
Terminal capacity
>Terminal screw
20, Class J A
Terminal capacity
>Tightening torque
18 - 14 AWG
Rated operational current for specified heat dissipation [In] M3.5
Heat dissipation per pole, current-dependent [Pvid] 8.8 lb-in
Equipment heat dissipation, current-dependent [Pvid] 20 A
Static heat dissipation, non-current-dependent [Pvs] 0.6 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+50 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
UV resistance only in connection with protective shield.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Model Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of poles The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
With 0 (off) position Reverser
With retraction in 0-position 8
Rated permanent current Iu Yes
Rated operation current Ie at AC-3, 400 V No
Rated operation power at AC-3, 400 V 20 A
Degree of protection (IP), front side 11.5 A
Degree of protection (NEMA), front side 4 kW
Number of auxiliary contacts as normally closed contact IP65
Number of auxiliary contacts as normally open contact 12
Number of auxiliary contacts as change-over contact 0
Suitable for ground mounting 0
Suitable for front mounting 4-hole 0
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Complete device in housing No
Material housing No
Type of control element No
Type of electrical connection of main circuit Plastic
Product Standards Toggle
UL File No. Screw connection
UL Category Control No. UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
CSA File No. E36332
CSA Class No. NLRV
North America Certification 12528
Specially designed for North America 3211-05
Suitable for UL listed, CSA certified
Degree of Protection Yes, with an alternative front plate and/or terminal markings to those of the IEC type in combination with "+NA" (105864)

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton