T0-3-8901/IVS
231940 T0-3-8901/IVS
231940

On-Off switch, T0, 20 A, service distribution board mounting, 3 contact unit(s), 3 pole + N, 1 N/O, 1 N/C, with black thumb grip and front plateOn-Off switch, Product range: On-Off switch, Part group reference: T0, with black thumb grip and front plate, 3 pole + N, Degree of Protection: Front IP30, Design: service distribution board mounting, Switching angle: 90 °, Switching performance: maintained, front plate: 0-1, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 5.5 kW, Rated uninterrupted current: Iu = 20 A, 3 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

On-Off switch, T0, 20 A, service distribution board mounting, 3 contact unit(s), 3 pole + N, 1 N/O, 1 N/C, with black thumb grip and front plate
On-Off switch, Product range: On-Off switch, Part group reference: T0, with black thumb grip and front plate, 3 pole + N, Degree of Protection: Front IP30, Design: service distribution board mounting, Switching angle: 90 °, Switching performance: maintained, front plate: 0-1, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 5.5 kW, Rated uninterrupted current: Iu = 20 A, 3 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

Product range On-Off switch
Part group reference T0
Number of poles with black thumb grip and front plate
Degree of Protection 3 pole + N
Design 1 N/O
Contact sequence 1 N/C
Switching angle Front IP30
Switching performance service distribution board mounting
Design number 000Z082
Front plate no. 115S209-2
front plate 90 °
400 V [P] maintained
Rated uninterrupted current [Iu] 8901
Note on rated uninterrupted current !u 115K001
Number of contact units 0-1
Standards 5.5 kW
Climatic proofing 20 A
Ambient temperature
>Open
Rated uninterrupted current Iu is specified for max. cross-section.
Ambient temperature
>Enclosed
3 contact unit(s)
Overvoltage category/pollution degree IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnector according to IEC/EN 60947-3
Rated impulse withstand voltage [Uimp] Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance -25 - +50 °C
Mounting position -25 - +40 °C
Mechanical variables
>Number of poles
III/3
Mechanical variables
>Auxiliary contacts
1 N/O
Mechanical variables
>Auxiliary contacts
1 N/C
Electrical characteristics
>Rated operational voltage [Ue]
6000 V AC
Electrical characteristics
>Rated uninterrupted current [Iu]
15 g
Electrical characteristics
>Note on rated uninterrupted current !u
As required
Load rating with intermittent operation, class 12
>AB 25 % DF
3 pole + N
Load rating with intermittent operation, class 12
>AB 40 % DF
1 N/O
Load rating with intermittent operation, class 12
>AB 60 % DF
1 N/C
Short-circuit rating
>Fuse
690 V AC
Rated short-time withstand current (1 s current) [Icw ] 20 A
Note on rated short-time withstand current lcw Rated uninterrupted current Iu is specified for max. cross-section.
Rated conditional short-circuit current [Iq] 2 x Ie
cos ϕ rated making capacity as per IEC 60947-3 1.6 x Ie
Rated breaking capacity cos ϕ to IEC 60947-3
>230 V
1.3 x Ie
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
20 A gG/gL
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
320 Arms
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
Current for a time of 1 second
Safe isolation to EN 61140
>between the contacts
6 kA
Safe isolation to EN 61140
>Current heat loss per contact at Ie
130 A
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
100 A
Lifespan, mechanical [Operations] 110 A
Maximum operating frequency [Operations/h] 80 A
AC
>AC-3
>Rating, motor load switch [P]
>220 V 230 V [P]
60 A
AC
>AC-3
>Rating, motor load switch [P]
>230 V Star-delta [P]
440 V AC
AC
>AC-3
>Rating, motor load switch [P]
>400 V 415 V [P]
0.6 W
AC
>AC-3
>Rating, motor load switch [P]
>400 V Star-delta [P]
0.6 CO
AC
>AC-3
>Rating, motor load switch [P]
>500 V [P]
> 0.4 x 106
AC
>AC-3
>Rating, motor load switch [P]
>500 V Star-delta [P]
1200
AC
>AC-3
>Rating, motor load switch [P]
>690 V [P]
3 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V Star-delta [P]
5.5 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V [Ie]
5.5 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V star-delta [Ie]
7.5 kW
AC
>AC-3
>Rated operational current motor load switch
>400V 415 V [Ie]
5.5 kW
AC
>AC-3
>Rated operational current motor load switch
>400 V star-delta [Ie]
7.5 kW
AC
>AC-3
>Rated operational current motor load switch
>500 V [Ie ]
4 kW
AC
>AC-3
>Rated operational current motor load switch
>500 V star-delta [Ie ]
5.5 kW
AC
>AC-3
>Rated operational current motor load switch
>690 V [Ie]
11.5 A
AC
>AC-3
>Rated operational current motor load switch
>690 V star-delta [Ie]
20 A
AC
>AC-21A
>Rated operational current switch
>440 V [Ie]
11.5 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>230 V [P]
20 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
9 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
15.6 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
4.9 A
AC
>AC-23A
>Rated operational current motor load switch
>230 V [Ie]
8.5 A
AC
>AC-23A
>Rated operational current motor load switch
>400 V 415 V [Ie]
20 A
AC
>AC-23A
>Rated operational current motor load switch
>500 V [Ie]
3 kW
AC
>AC-23A
>Rated operational current motor load switch
>690 V [Ie]
5.5 kW
DC
>DC-1, Load-break switches L/R = 1 ms
>Rated operational current [Ie]
7.5 kW
DC
>DC-1, Load-break switches L/R = 1 ms
>Voltage per contact pair in series
5.5 kW
DC
>DC-21A [Ie ]
>Rated operational current [Ie]
13.3 A
DC
>DC-21A [Ie ]
>Contacts
13.3 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Rated operational current [Ie]
13.3 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Contacts
7.6 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Rated operational current [Ie]
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Contacts
60 V
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Rated operational current [Ie]
1 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Contacts
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Rated operational current [Ie]
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Contacts
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Rated operational current [Ie]
10 A
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Contacts
2 Quantity
DC
>DC-13, Control switches L/R = 50 ms
>Rated operational current [Ie]
10 A
DC
>DC-13, Control switches L/R = 50 ms
>Voltage per contact pair in series
3 Quantity
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 5 A
Solid or stranded 3 Quantity
Flexible with ferrules to DIN 46228 5 A
Terminal screw 5 Quantity
Tightening torque for terminal screw 10 A
Notes 32 V
Contacts
>Rated operational voltage [Ue]
< 10 -5, < 1 fault in 100000 operations HF
Contacts
>Rated uninterrupted current max.
>Main conducting paths
>General use
1 x (1 - 2,5)
2 x (1 - 2,5) mm2
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>General Use [IU]
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>Pilot Duty
M3.5
Switching capacity
>Maximum motor rating
>Single-phase
>120 V AC
1 Nm
Switching capacity
>Maximum motor rating
>Single-phase
>200 V AC
B10d values as per EN ISO 13849-1, table C1
Switching capacity
>Maximum motor rating
>Single-phase
>240 V AC
600 V AC
Switching capacity
>Maximum motor rating
>Three-phase
>200 V AC
16 A
Switching capacity
>Maximum motor rating
>Three-phase
>240 V AC
10 A
Switching capacity
>Maximum motor rating
>Three-phase
>480 V AC
A 600
P 600
Switching capacity
>Maximum motor rating
>Three-phase
>600 V AC
0.5 HP
Short Circuit Current Rating
>Basic Rating
1 HP
Short Circuit Current Rating
>max. Fuse
1.5 HP
Short Circuit Current Rating
>High fault rating
3 HP
Short Circuit Current Rating
>max. Fuse
3 HP
Terminal capacity
>Solid or flexible conductor with ferrule
7.5 HP
Terminal capacity
>Terminal screw
7.5 HP
Terminal capacity
>Tightening torque
5 kA
Rated operational current for specified heat dissipation [In] 50 A
Heat dissipation per pole, current-dependent [Pvid] 10 kA
Equipment heat dissipation, current-dependent [Pvid] 20, Class J A
Static heat dissipation, non-current-dependent [Pvs] 18 - 14 AWG
Heat dissipation capacity [Pdiss] M3.5
Operating ambient temperature min. 8.8 lb-in
Operating ambient temperature max. 20 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0.6 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
-25 °C
10.2 Strength of materials and parts
>10.2.5 Lifting
+50 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Version as main switch Is the panel builder´s responsibility.
Version as maintenance-/service switch Is the panel builder´s responsibility.
Version as safety switch The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Version as emergency stop installation Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Version as reversing switch Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of switches The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Max. rated operation voltage Ue AC No
Rated operating voltage No
Rated permanent current Iu No
Rated permanent current at AC-23, 400 V No
Rated permanent current at AC-21, 400 V No
Rated operation power at AC-3, 400 V 1
Rated short-time withstand current lcw 690 V
Rated operation power at AC-23, 400 V 690 - 690 V
Switching power at 400 V 20 A
Conditioned rated short-circuit current Iq 13.3 A
Number of poles 20 A
Number of auxiliary contacts as normally closed contact 5.5 kW
Number of auxiliary contacts as normally open contact 0.32 kA
Number of auxiliary contacts as change-over contact 5.5 kW
Motor drive optional 5.5 kW
Motor drive integrated 6 kA
Voltage release optional 4
Device construction 1
Suitable for ground mounting 1
Suitable for front mounting 4-hole 0
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting No
Colour control element Built-in device fixed built-in technique
Type of control element Yes
Interlockable No
Type of electrical connection of main circuit No
Degree of protection (IP), front side Yes
Degree of protection (NEMA) No
Product Standards Black
UL File No. Toggle
UL Category Control No. No
CSA File No. Screw connection
CSA Class No. IP30
North America Certification Other
Suitable for UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
Degree of Protection E36332

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton