alt
alt

SPX125A1-4A1B1
134489 SPX125A1-4A1B1
134489

Variable frequency drive, 400 V AC, 3-phase, 90 kW, IP21, Radio interference suppression filter, Brake chopper, OLED display, FR8Variable frequency drive, Part group reference (e.g. DIL): SPX, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 170 A, Rated operational current At 110% overload: Ie = 205 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For AC motors with internal and external ventilation with 50 Hz / 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 90 kW, 110 % Overload: P = 110 kW, 150 % Overload: IM = 161 A, 110 % Overload: IM = 196 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 125 HP, 110 % Overload: P = 150 HP, Assigned motor rating 150 % Overload: IM = 156 A, 110 % Overload: IM = 180 A, Degree of Protection: IP21, Fieldbus connection (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Fitted with: Radio interference suppression filter, Brake chopper, OLED display, DC link choke, Frame size: FR8, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Variable frequency drive, 400 V AC, 3-phase, 90 kW, IP21, Radio interference suppression filter, Brake chopper, OLED display, FR8
Variable frequency drive, Part group reference (e.g. DIL): SPX, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 170 A, Rated operational current At 110% overload: Ie = 205 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For AC motors with internal and external ventilation with 50 Hz / 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 90 kW, 110 % Overload: P = 110 kW, 150 % Overload: IM = 161 A, 110 % Overload: IM = 196 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 125 HP, 110 % Overload: P = 150 HP, Assigned motor rating 150 % Overload: IM = 156 A, 110 % Overload: IM = 180 A, Degree of Protection: IP21, Fieldbus connection (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Fitted with: Radio interference suppression filter, Brake chopper, OLED display, DC link choke, Frame size: FR8, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Product range Variable frequency drives
Part group reference (e.g. DIL) SPX
Rated operational voltage [Ue] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Output voltage with Ve [U2] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Mains voltage (50/60Hz) [ULN] 380 (-15%) - 500 (+10%) V
At 150% overload [Ie]
At 110% overload [Ie] 170 A
Note 205 A
Note
Note For AC motors with internal and external ventilation with 50 Hz / 60 Hz
150 % Overload [P] Overload cycle for 60 s every 600 s
110 % Overload [P] at 400 V, 50 Hz
150 % Overload [IM] 90 kW
110 % Overload [IM] 110 kW
Note 161 A
150 % Overload [P] 196 A
110 % Overload [P] at 440 - 480 V, 60 Hz
150 % Overload [IM] 125 HP
110 % Overload [IM] 150 HP
Degree of Protection 156 A
Fieldbus connection (optional) 180 A
Fitted with IP21
Frame size PROFIBUS-DP
PROFINET
EtherCAT
EtherNet/IP
LonWorks
CANopen®
DeviceNet
Modbus-TCP
Modbus-RTU
BACnet MS/TP
Connection to SmartWire-DT Radio interference suppression filter
Brake chopper
OLED display
Standards FR8
Certifications no
Approvals
Production quality Specification for general requirements: IEC/EN 61800-2
EMC requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5-1
Climatic proofing [ρw] CE, UL, cUL, RCM
Ambient temperature
>Operating ambient temperature min.
DNV
Ambient temperature
>Operating ambient temperature max.
RoHS, ISO 9001
Ambient temperature
>operation (110 % overload) [ϑ]
< 95% relative humidity, no condensation, no corrosion, no dripping water %
Ambient temperature
>Storage [ϑ]
-10 °C
Radio interference level
>Radio interference class (EMC)
+50 °C
Radio interference level
>Environment (EMC)
-10 - +40 °C
Mounting position -40 - +70 °C
Altitude C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Degree of Protection 1st and 2nd environments as per EN 61800-3
Protection against direct contact Vertical
Supply
>Rated operational voltage [Ue]
0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m m
Supply
>Mains voltage (50/60Hz) [ULN]
IP21
Supply
>System configuration
BGV A3 (VBG4, finger- and back-of-hand proof)
Supply
>Supply frequency [fLN]
Supply
>Frequency range [fLN]
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Power section
>Function
380 (-15%) - 500 (+10%) V
Power section
>Output voltage with Ve [U2]
AC supply systems with earthed center point
Power section
>Output Frequency [f2]
50/60 Hz
Power section
>Switching frequency [fPWM]
45–66 (± 0%) Hz
Power section
>Operation Mode
Variable frequency drive with internal DC link and IGBT inverter
Power section
>Frequency resolution (setpoint value) [Δf]
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Power section
>Rated operational current
>At 150% overload [Ie]
0 - 50/60 (max. 320) Hz
Power section
>Rated operational current
>At 110% overload [Ie]
3.6
adjustable 1 - 10 kHz
Power section
>Fitted with
U/f control
sensorless vector control (SLV)
optional: Vector control with feedback (CLV)
Power section
>Frame size
0.01 Hz
Motor feeder
>Note
170 A
Motor feeder
>Note
205 A
Motor feeder
>Note
Radio interference suppression filter
Brake chopper
OLED display
Motor feeder
>150 % Overload [P]
FR8
Motor feeder
>110 % Overload [P]
For AC motors with internal and external ventilation with 50 Hz / 60 Hz
Motor feeder
>Note
Overload cycle for 60 s every 600 s
Motor feeder
>150 % Overload [P]
at 400 V, 50 Hz
Motor feeder
>110 % Overload [P]
90 kW
External control voltage [Uc] 110 kW
Reference voltage [Us] at 440 - 480 V, 60 Hz
Analog inputs 125 HP
Analog outputs 150 HP
Digital inputs
Digital outputs 24 V DC (max. 250 mA) V
Relay outputs 10 V DC (max. 10 mA) V
Power Wiring
>Main choke
>150 % overload (CT/IH, at 50 °C)
2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA
Power Wiring
>Note regarding mains choke
1, parameterizable, 0/4 - 20 mA
Motor feeder
>motor choke
>150 % overload (CT/IH, at 50 °C)
6, parameterizable, max. 30 V DC
Motor feeder
>motor choke
>110 % overload (VT/IL, at 40 °C)
1, parameterizable, 48 V DC/50 mA
Motor feeder
>Sine filter
>150 % overload (CT/IH, at 50 °C)
2, parameterizable, N/O, 8 A (24 V DC) / 8 A (250 V AC) / 0,4 A (125 V DC)
Motor feeder
>Sine filter
>110 % overload (VT/IL, at 40 °C)
Rated operational current for specified heat dissipation [In] DX-LN3-250
Equipment heat dissipation, current-dependent [Pvid] Mains choke recommended only if the power quality is poor. Current harmonics (THD) are attenuated by internal DC link chokes.
Operating ambient temperature min. DX-LM3-180
Operating ambient temperature max. DX-LM3-220
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
DX-SIN3-180
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
DX-SIN3-250
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
170 A
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
2250 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-10 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+50 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Is the panel builder´s responsibility.
Product Standards Is the panel builder´s responsibility.
UL File No. Is the panel builder´s responsibility.
UL Category Control No. Is the panel builder´s responsibility.
CSA File No. Is the panel builder´s responsibility.
CSA Class No. The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
North America Certification Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Specially designed for North America Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Suitable for The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Max. Voltage Rating UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking
Degree of Protection E134360

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DA1-32110FB-B55C
Eaton
DA1-32150FB-B55C
Eaton
DA1-32180FB-B55C
Eaton
DA1-32202FB-B55C
Eaton
DA1-32248FB-B55C
Eaton
DA1-342D2FB-B66C
Eaton
DA1-342D2FB-B6SC
Eaton
DA1-344D1FB-B66C
Eaton
DA1-344D1FB-B6SC
Eaton