Variable frequency drive, 600 V AC, 3-phase, 37 kW, IP54, Radio interference suppression filter, OLED display, FR7Variable frequency drive, Part group reference (e.g. DIL): SPX, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 525 (-15%) - 690 (±10%) V, Rated operational current At 150% overload: Ie = 41 A, Rated operational current At 110% overload: Ie = 52 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For AC motors with internal and external ventilation with 50 Hz / 60 Hz, Overload cycle for 60 s every 600 s, at 690 V, 50 Hz, Assigned motor rating 150 % Overload: P = 37 kW, 110 % Overload: P = 45 kW, 150 % Overload: IM = 39 A, 110 % Overload: IM = 47 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 40 HP, 110 % Overload: P = 50 HP, Assigned motor rating 150 % Overload: IM = 36 A, 110 % Overload: IM = 45 A, Degree of Protection: IP54, Fieldbus connection (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Fitted with: Radio interference suppression filter, OLED display, DC link choke, Frame size: FR7, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Variable frequency drive, 600 V AC, 3-phase, 37 kW, IP54, Radio interference suppression filter, OLED display, FR7
Variable frequency drive, Part group reference (e.g. DIL): SPX, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 525 (-15%) - 690 (±10%) V, Rated operational current At 150% overload: Ie = 41 A, Rated operational current At 110% overload: Ie = 52 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For AC motors with internal and external ventilation with 50 Hz / 60 Hz, Overload cycle for 60 s every 600 s, at 690 V, 50 Hz, Assigned motor rating 150 % Overload: P = 37 kW, 110 % Overload: P = 45 kW, 150 % Overload: IM = 39 A, 110 % Overload: IM = 47 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 40 HP, 110 % Overload: P = 50 HP, Assigned motor rating 150 % Overload: IM = 36 A, 110 % Overload: IM = 45 A, Degree of Protection: IP54, Fieldbus connection (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Fitted with: Radio interference suppression filter, OLED display, DC link choke, Frame size: FR7, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Product range | Variable frequency drives |
Part group reference (e.g. DIL) | SPX |
Rated operational voltage [Ue] | 600 V AC, 3-phase 690 V AC, 3-phase |
Output voltage with Ve [U2] | 600 V AC, 3-phase 690 V AC, 3-phase |
Mains voltage (50/60Hz) [ULN] | 525 (-15%) - 690 (±10%) V |
At 150% overload [Ie] | |
At 110% overload [Ie] | 41 A |
Note | 52 A |
Note | |
Note | For AC motors with internal and external ventilation with 50 Hz / 60 Hz |
150 % Overload [P] | Overload cycle for 60 s every 600 s |
110 % Overload [P] | at 690 V, 50 Hz |
150 % Overload [IM] | 37 kW |
110 % Overload [IM] | 45 kW |
Note | 39 A |
150 % Overload [P] | 47 A |
110 % Overload [P] | at 690 V, 60 Hz |
150 % Overload [IM] | 40 HP |
110 % Overload [IM] | 50 HP |
Degree of Protection | 36 A |
Fieldbus connection (optional) | 45 A |
Fitted with | IP54 |
Frame size | PROFIBUS-DP PROFINET EtherCAT EtherNet/IP LonWorks CANopen® DeviceNet Modbus-TCP Modbus-RTU BACnet MS/TP |
Connection to SmartWire-DT | Radio interference suppression filter OLED display |
Standards | FR7 |
Certifications | no |
Approvals | |
Production quality | Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5-1 |
Climatic proofing [ρw] | CE, UL, cUL, RCM |
Ambient temperature >Operating ambient temperature min. |
DNV |
Ambient temperature >Operating ambient temperature max. |
RoHS, ISO 9001 |
Ambient temperature >operation (110 % overload) [ϑ] |
< 95% relative humidity, no condensation, no corrosion, no dripping water % |
Ambient temperature >Storage [ϑ] |
-10 °C |
Radio interference level >Radio interference class (EMC) |
+50 °C |
Radio interference level >Environment (EMC) |
-10 - +40 °C |
Mounting position | -40 - +70 °C |
Altitude | C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. |
Degree of Protection | 1st and 2nd environments as per EN 61800-3 |
Protection against direct contact | Vertical |
Supply >Rated operational voltage [Ue] |
0 - 1000 m above sea level above 1000 m with 1 % performance reduction per 100 m max. 3000 m m |
Supply >Mains voltage (50/60Hz) [ULN] |
IP54 |
Supply >System configuration |
BGV A3 (VBG4, finger- and back-of-hand proof) |
Supply >Supply frequency [fLN] |
|
Supply >Frequency range [fLN] |
600 V AC, 3-phase 690 V AC, 3-phase |
Power section >Function |
525 (-15%) - 690 (±10%) V |
Power section >Output voltage with Ve [U2] |
AC supply systems with earthed center point |
Power section >Output Frequency [f2] |
50/60 Hz |
Power section >Switching frequency [fPWM] |
45–66 (± 0%) Hz |
Power section >Operation Mode |
Variable frequency drive with internal DC link and IGBT inverter |
Power section >Frequency resolution (setpoint value) [Δf] |
600 V AC, 3-phase 690 V AC, 3-phase |
Power section >Rated operational current >At 150% overload [Ie] |
0 - 50/60 (max. 320) Hz |
Power section >Rated operational current >At 110% overload [Ie] |
1.5 adjustable 1 - 6 kHz |
Power section >Fitted with |
U/f control sensorless vector control (SLV) optional: Vector control with feedback (CLV) |
Power section >Frame size |
0.01 Hz |
Motor feeder >Note |
41 A |
Motor feeder >Note |
52 A |
Motor feeder >Note |
Radio interference suppression filter OLED display |
Motor feeder >150 % Overload [P] |
FR7 |
Motor feeder >110 % Overload [P] |
For AC motors with internal and external ventilation with 50 Hz / 60 Hz |
Motor feeder >Note |
Overload cycle for 60 s every 600 s |
Motor feeder >150 % Overload [P] |
at 690 V, 50 Hz |
Motor feeder >110 % Overload [P] |
37 kW |
External control voltage [Uc] | 45 kW |
Reference voltage [Us] | at 690 V, 60 Hz |
Analog inputs | 40 HP |
Analog outputs | 50 HP |
Digital inputs | |
Digital outputs | 24 V DC (max. 250 mA) V |
Relay outputs | 10 V DC (max. 10 mA) V |
Power Wiring >Main choke >150 % overload (CT/IH, at 50 °C) |
2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA |
Motor feeder >motor choke >150 % overload (CT/IH, at 50 °C) |
1, parameterizable, 0/4 - 20 mA |
Motor feeder >motor choke >110 % overload (VT/IL, at 40 °C) |
6, parameterizable, max. 30 V DC |
Motor feeder >Sine filter >150 % overload (CT/IH, at 50 °C) |
1, parameterizable, 48 V DC/50 mA |
Motor feeder >Sine filter >110 % overload (VT/IL, at 40 °C) |
2, parameterizable, N/O, 8 A (24 V DC) / 8 A (250 V AC) / 0,4 A (125 V DC) |
Rated operational current for specified heat dissipation [In] | |
Heat dissipation per pole, current-dependent [Pvid] | DX-LN3-080 |
Equipment heat dissipation, current-dependent [Pvid] | DX-LM3-050 |
Static heat dissipation, non-current-dependent [Pvs] | DX-LM3-063 |
Heat dissipation capacity [Pdiss] | SIN-0052-6-0-P |
Operating ambient temperature min. | SIN-0052-6-0-P |
Operating ambient temperature max. | |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
41 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
925 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-10 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+50 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Operation (with 150 % overload) |
10.3 Degree of protection of ASSEMBLIES | |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise | Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating | Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility | Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function | Does not apply, since the entire switchgear needs to be evaluated. |
Product Standards | Is the panel builder´s responsibility. |
UL File No. | Is the panel builder´s responsibility. |
UL Category Control No. | Is the panel builder´s responsibility. |
CSA File No. | Is the panel builder´s responsibility. |
CSA Class No. | Is the panel builder´s responsibility. |
North America Certification | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Specially designed for North America | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Suitable for | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Max. Voltage Rating | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Degree of Protection | UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.