Accessories |
Suppressor circuit |
Description |
RC suppressor |
Actuating voltage [Us] |
24 - 48 AC V |
Contact sequence |
|
For use with |
DILE…-C |
Instructions |
For AC operation contactors 50 - 60 Hz. The suppressor is fitted as standard in DC operated contactor relays. Note drop-out delay |
Rated operational current for specified heat dissipation [In] |
|
Heat dissipation per pole, current-dependent [Pvid] |
0 A |
Equipment heat dissipation, current-dependent [Pvid] |
0 W |
Static heat dissipation, non-current-dependent [Pvs] |
0 W |
Heat dissipation capacity [Pdiss] |
0 W |
Operating ambient temperature min. |
0 W |
Operating ambient temperature max. |
-25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+50 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.13 Mechanical function |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Function |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated control supply voltage Us at AC 50HZ |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated control supply voltage Us at AC 60HZ |
|
Rated control supply voltage Us at DC |
|
Voltage type for actuating |
RC-element |
With LED indication |
48 - 48 V |
Product Standards |
48 - 48 V |
UL File No. |
0 - 0 V |
UL Category Control No. |
AC |
CSA File No. |
No |
North America Certification |
IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking |
Specially designed for North America |
E29184 |