alt
alt

QSA400N-2/3N.
1318614 QSA400N-2/3N.
1318614

Fuse switch-disconnector, 3P + N (switched), rear mounting, 400 A, NH1/NH2QSA400N-2/3N fuse-switch-disconnector; frame size 2; suitable for DIN fuse-links (blade contacts type)

Fuse switch-disconnector, 3P + N (switched), rear mounting, 400 A, NH1/NH2
QSA400N-2/3N fuse-switch-disconnector; frame size 2; suitable for DIN fuse-links (blade contacts type)

Product range Fuse-switch-disconnector
Main switch
maintenance switch
Part group reference QSA
Stop Function optional
Notes Suitable for DIN fuse-links (blade contacts type)
Information about equipment supplied auxiliary contact fitted by user.
Number of poles 3P + N (switched)
Degree of Protection 0 N/O
Design 0 N/C
Contact sequence IP00
IP20 with terminal cover
Rated uninterrupted current [Iu] rear mounting
Note on rated uninterrupted current !u 000Z429
Fuse cartridge 115S262
Standards 400 A
Certifications Rated uninterrupted current Iu is specified for max. cross-section.
In ventilated enclosure.
Ambient temperature
>Operation [ϑ]
NH1/NH2 Size
Ambient temperature
>Storage [ϑ]
IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch disconnector in accordance with IEC/EN 60947-11
Overvoltage category/pollution degree CE, RoHs
Rated impulse withstand voltage [Uimp] -25 - +55 °C
Rated insulation voltage [Ui ] -30 - +80 °C
Mounting position III/3
Mechanical variables
>Number of poles
6 kV
Mechanical variables
>Auxiliary contacts
0 N/O
Mechanical variables
>Auxiliary contacts
0 N/C
Electrical characteristics
>Rated operational voltage [Ue]
690 V
Electrical characteristics
>Rated uninterrupted current [Iu]
As required
Electrical characteristics
>Note on rated uninterrupted current !u
3P + N (switched)
Heat dissipation per pole, current-dependent [Pvid] 0 N/O
Rated operational current for specified heat dissipation [In] 0 N/C
Heat dissipation per pole, current-dependent [Pvid] 690 V AC
Equipment heat dissipation, current-dependent [Pvid] 400 A
Static heat dissipation, non-current-dependent [Pvs] Rated uninterrupted current Iu is specified for max. cross-section.
In ventilated enclosure.
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 400 A
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
-25 °C
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
+55 °C
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Version as main switch Is the panel builder´s responsibility.
Version as safety switch The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Max. rated operation voltage Ue AC Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated permanent current Iu Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power at AC-23, 400 V The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Conditioned rated short-circuit current Iq Yes
Rated short-time withstand current lcw No
Suitable for fuses 690 V
Number of poles 400 A
With error protection 220 kW
Type of electrical connection of main circuit 50 kA
Cable entry 0 kA
Equipped with connectors NH1, NH2
Suitable for ground mounting 4
Suitable for front mounting 4-hole No
Suitable for busbar mounting Screw connection
Type of control element Other
Position control element Yes
Motor drive optional Yes
Motor drive integrated No
Version as emergency stop installation No
Degree of protection (IP), front side Other

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton