Product range |
RMQ16 |
Basic function |
Illuminated pushbutton actuators |
Single unit/Complete unit |
Single unit |
Design |
Flat |
Lens |
maintained |
button plate |
|
Button plate |
green |
Degree of Protection |
|
Connection to SmartWire-DT |
Blank |
Front dimensions |
IP65 |
Standards |
no |
Lifespan, mechanical [Operations] |
25 x 25 |
Operating frequency [Operations/h] |
IEC/EN 60947 |
Actuating force |
> 30 x 106 |
Degree of protection, IEC/EN 60529 |
≦ 1800 |
Climatic proofing |
≦ 4 n |
Ambient temperature >Open |
IP65 |
Ambient temperature >Enclosed |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mounting position |
-25 - +60 °C |
Mechanical shock resistance |
- 25 - 40 °C |
Terminal capacities |
As required |
Blade terminal |
> 40 according to IEC 60068-2-27 Shock duration 11 ms Sinusoidal g |
Fast-on connectors |
0.5 - 1.0 mm2
|
Rated impulse withstand voltage [Uimp] |
2.8 x 0.8 mm to DIN 46244 |
Rated insulation voltage [Ui
] |
2.8 x 0.8 mm to DIN 46247 and IEC 60760 |
Overvoltage category/pollution degree |
800 V AC |
Rated operational voltage [Ue] |
250 V |
Control circuit reliability >at 24 V DC/5 mA [HF
] |
III/3 |
Control circuit reliability >at 5 V DC/1 mA [HF
] |
24 V AC |
Use of insulated ferrule ISH 2,8 |
< 10-7, < 1 fault in 107 operations Fault probability |
Rated operational current for specified heat dissipation [In] |
< 5 x 10-6 (1 failure in 5 x 106 operations) Fault probability |
Heat dissipation per pole, current-dependent [Pvid] |
>24 V AC/DC recommended >50 V AC or 120 V DC is mandatory, even on unused blade terminals |
Equipment heat dissipation, current-dependent [Pvid] |
0 A |
Static heat dissipation, non-current-dependent [Pvs] |
0 W |
Heat dissipation capacity [Pdiss] |
0 W |
Operating ambient temperature min. |
1 W |
Operating ambient temperature max. |
0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
-25 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
+60 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Please enquire |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.13 Mechanical function |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Colour button |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of command positions |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Construction type lens |
Green |
Hole diameter |
1 |
Width opening |
Square |
Height opening |
16 mm |
Type of button |
0 mm |
Suitable for illumination |
0 mm |
With protective cover |
Flat |
Labelled |
Yes |
Switching function latching |
No |
Spring-return |
No |
With front ring |
Yes |
Material front ring |
No |
Colour front ring |
Yes |
Degree of protection (IP), front side |
Plastic |
Degree of protection (NEMA), front side |
Black |
Product Standards |
IP65 |
UL File No. |
1 |
UL Category Control No. |
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CE marking |
CSA File No. |
E29184 |
CSA Class No. |
NKCR |
North America Certification |
46552 |
Degree of Protection |
3211-03 |