| Product range |
RMQ16 |
| Basic function |
Indicator lights |
| Single unit/Complete unit |
Single unit |
| Design |
Flat |
| Description |
without light elements With base, W2x4,6d; max. 30 V, 1 W |
| Lens |
Red |
| Lens |
 |
| Degree of Protection |
IP65 |
| Connection to SmartWire-DT |
no |
| Front dimensions |
Front dimensions 18 × 18 mm |
| Standards |
IEC/EN 60947 |
| Degree of protection, IEC/EN 60529 |
IP65 |
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Open |
-25 - +60 °C |
Ambient temperature >Enclosed |
- 25 - 40 °C |
| Mounting position |
As required |
| Mechanical shock resistance |
> 40 according to IEC 60068-2-27 Shock duration 11 ms Sinusoidal g |
| Terminal capacities |
0.5 - 1.0 mm2
|
| Blade terminal |
2.8 x 0.8 mm to DIN 46244 |
| Fast-on connectors |
2.8 x 0.8 mm to DIN 46247 and IEC 60760 |
| Rated impulse withstand voltage [Uimp] |
800 V AC |
| Rated insulation voltage [Ui
] |
250 V |
| Overvoltage category/pollution degree |
III/3 |
| Rated operational voltage [Ue] |
24 V AC |
| Use of insulated ferrule ISH 2,8 |
>24 V AC/DC recommended >50 V AC or 120 V DC is mandatory, even on unused blade terminals |
| Rated operational current for specified heat dissipation [In] |
0 A |
| Heat dissipation per pole, current-dependent [Pvid] |
0 W |
| Equipment heat dissipation, current-dependent [Pvid] |
0 W |
| Static heat dissipation, non-current-dependent [Pvs] |
0 W |
| Heat dissipation capacity [Pdiss] |
0 W |
| Operating ambient temperature min. |
-25 °C |
| Operating ambient temperature max. |
+60 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
| 10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
| 10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated. |
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
| 10.7 Internal electrical circuits and connections |
Is the panel builder´s responsibility. |
| 10.8 Connections for external conductors |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
| 10.10 Temperature rise |
Not applicable. |
| 10.11 Short-circuit rating |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
| 10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
| Suitable for number of built-in signal lights |
1 |
| Colour lens |
Red |
| Construction type lens |
Square |
| Hole diameter |
16 mm |
| Width opening |
0 mm |
| Height opening |
0 mm |
| With front ring |
Yes |
| Material front ring |
Plastic |
| Colour front ring |
Black |
| Type of lens |
Flat |
| Degree of protection (IP), front side |
IP65 |
| Product Standards |
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CE marking |
| UL File No. |
E29184 |
| UL Category Control No. |
NKCR |
| CSA File No. |
46552 |
| CSA Class No. |
3211-03 |
| North America Certification |
UL listed, CSA certified |
| Degree of Protection |
UL/CSA Type 1 |