Wiring set, For DOL Starter, DILM7-M15Wiring set can be used for DOL starter for PKZM0 + DILM7, PKZM0 + DILM9, PKZM0 + DILM12, PKZM0 + DILM15
Wiring set, For DOL Starter, DILM7-M15
Wiring set can be used for DOL starter for PKZM0 + DILM7, PKZM0 + DILM9, PKZM0 + DILM12, PKZM0 + DILM15
Product range | Accessories |
Accessories | Wiring set |
For use with | For DOL Starter |
Equipment supplied: | PKZM0, PKE + DILM7 PKZM0, PKE + DILM9 PKZM0, PKE + DILM12 PKZM0, PKE + DILM15 DS7-34…SX004… DS7-34…SX007… DS7-34…SX009… DS7-34…SX012… |
Instructions | Mechanical connection element for PKZM0 and contactor + main current wiring between PKZM0 and contactor with tool-less plug connection + cable routing |
Rated operational current for specified heat dissipation [In] | Use as auxiliary contact DILA‐XHIT... Cannot be combined with NHI‐E…PKZ0‐C. Ue ≦ 415 V |
Heat dissipation per pole, current-dependent [Pvid] | |
Equipment heat dissipation, current-dependent [Pvid] | 15.5 A |
Static heat dissipation, non-current-dependent [Pvs] | 0.5 W |
Heat dissipation capacity [Pdiss] | 1.5 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
-25 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
+55 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
|
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Suitable for number of poles | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Model | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Product Standards | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
UL File No. | |
UL Category Control No. | |
CSA File No. | 3 |
CSA Class No. | Direct circuit |
North America Certification | UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking |
Specially designed for North America | E36332 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.