Product range |
Accessories |
Accessories |
Overload relay function |
Actuating voltage |
Can be mounted on the right side of PKE motor-protective circuit-breakers with advanced PKE-XTU…A… trip blocks Overload relay function: the motor-protective circuit-breaker will not trip in the event of an overload. 1 N/O: for trip indication 1 N/C: for switching off the contactor Status display via LED. Adjustable manual/auto reset. External control voltage supply required. |
For use with |
24 V DC |
N/O = Normally open |
Overload relay function PKE |
N/C = Normally closed |
|
Contact sequence |
1 N/O |
For use with |
1 NC |
Rated impulse withstand voltage [Uimp] |
|
Overvoltage category/pollution degree |
PKE12 PKE32 PKE65 with XTUA trip block with release 04 and higher |
Rated operational voltage [Ue] [Ue
] |
|
Safe isolation to EN 61140 >Between auxiliary contacts and main contacts |
6000 V AC |
Rated operational current [Ie
] >DC-13 L/R - 100 ms >24 V [Ie
] |
III/3 |
Lifespan >Lifespan, mechanical [Operations] |
250 V DC |
Lifespan >Lifespan, electrical [Operations] |
690 V AC |
Short-circuit rating without welding >Fuse |
1.5 A |
Solid or flexible conductor, with ferrule |
> 5 x 106 |
Solid or stranded |
0.2 x 106
|
Actuating voltage |
6 A gG/gL |
DC Voltage |
|
DC current >Pull-in power [Pick-up] |
0,75 - 2,5 mm2
|
Rated operational current for specified heat dissipation [In] |
18 - 14 AWG |
Heat dissipation per pole, current-dependent [Pvid] |
|
Equipment heat dissipation, current-dependent [Pvid] |
24 V DC |
Static heat dissipation, non-current-dependent [Pvs] |
0.8 - 1.1 x US |
Heat dissipation capacity [Pdiss] |
|
Operating ambient temperature min. |
0.5 W |
Operating ambient temperature max. |
|
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
1.5 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0.017 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0.61 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-25 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+55 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
|
10.3 Degree of protection of ASSEMBLIES |
Meets the product standard´s requirements. |
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Is the panel builder´s responsibility. |
Adjustable current range |
Is the panel builder´s responsibility. |
Mounting method |
Is the panel builder´s responsibility. |
Type of electrical connection of main circuit |
Is the panel builder´s responsibility. |
Number of auxiliary contacts as normally closed contact |
Is the panel builder´s responsibility. |
Number of auxiliary contacts as normally open contact |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Number of auxiliary contacts as change-over contact |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated control supply voltage Us at AC 50HZ |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated control supply voltage Us at AC 60HZ |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated control supply voltage Us at DC |
|
Release class |
|
Voltage type for actuating |
0 - 0 A |
Reset function automatic |
Direct attachment |
Reset function input |
Other |
Reset function push-button |
1 |
Specially designed for North America |
1 |