alt
alt

P1-32/I2H/SVB/HI11
227870 P1-32/I2H/SVB/HI11
227870

Main switch, P1, 32 A, surface mounting, 3 pole, 1 N/O, 1 N/C, Emergency switching off function, With red rotary handle and yellow locking ring, Lockable in the 0 (Off) position, hard knockout versionMain switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: P1, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, Notes: hard knockout version, Information about equipment supplied: Auxiliary contact or neutral conductor fitted by user., 3 pole, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65, Design: surface mounting, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 15 kW, Rated uninterrupted current: Iu = 32 A, Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Main switch, P1, 32 A, surface mounting, 3 pole, 1 N/O, 1 N/C, Emergency switching off function, With red rotary handle and yellow locking ring, Lockable in the 0 (Off) position, hard knockout version
Main switch, Product range: Main switch, maintenance switch, Repair switch, Part group reference: P1, Stop Function: Emergency switching off function, With red rotary handle and yellow locking ring, Notes: hard knockout version, Information about equipment supplied: Auxiliary contact or neutral conductor fitted by user., 3 pole, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65, Design: surface mounting, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 15 kW, Rated uninterrupted current: Iu = 32 A, Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Product range Main switch
maintenance switch
Repair switch
Part group reference P1
Stop Function Emergency switching off function
Information about equipment supplied With red rotary handle and yellow locking ring
Notes Auxiliary contact or neutral conductor fitted by user.
Number of poles hard knockout version
Locking facility 3 pole
Degree of Protection 1 N/O
Design 1 N/C
Contact sequence Lockable in the 0 (Off) position
Function IP65
400 V [P] 000Z083
Rated uninterrupted current [Iu] surface mounting
Note on rated uninterrupted current !u 000Z428
Standards 115S208-2
Climatic proofing 1150SPC-194
Ambient temperature
>Enclosed
15 kW
Overvoltage category/pollution degree 32 A
Rated impulse withstand voltage [Uimp] Rated uninterrupted current Iu is specified for max. cross-section.
Mechanical shock resistance IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Mounting position Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical variables
>Number of poles
-25 - +40 °C
Mechanical variables
>Auxiliary contacts
1 N/O
Mechanical variables
>Auxiliary contacts
1 N/C
Electrical characteristics
>Rated operational voltage [Ue]
III/3
Electrical characteristics
>Rated uninterrupted current [Iu]
6000 V AC
Electrical characteristics
>Note on rated uninterrupted current !u
15 g
Load rating with intermittent operation, class 12
>AB 25 % DF
As required
Load rating with intermittent operation, class 12
>AB 40 % DF
3 pole
Load rating with intermittent operation, class 12
>AB 60 % DF
1 N/O
Short-circuit rating
>Fuse
1 N/C
Rated short-time withstand current (1 s current) [Icw ] 690 V AC
Note on rated short-time withstand current lcw 32 A
Rated conditional short-circuit current [Iq] Rated uninterrupted current Iu is specified for max. cross-section.
cos ϕ rated making capacity as per IEC 60947-3 2 x Ie
Rated breaking capacity cos ϕ to IEC 60947-3
>230 V
1.6 x Ie
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
1.3 x Ie
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
50 A gG/gL
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
640 Arms
Safe isolation to EN 61140
>between the contacts
Current for a time of 1 second
Safe isolation to EN 61140
>Current heat loss per contact at Ie
80 kA
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
320 A
Lifespan, mechanical [Operations] 260 A
Maximum operating frequency [Operations/h] 300 A
AC
>AC-3
>Rating, motor load switch [P]
>220 V 230 V [P]
290 A
AC
>AC-3
>Rating, motor load switch [P]
>400 V 415 V [P]
250 A
AC
>AC-3
>Rating, motor load switch [P]
>500 V [P]
440 V AC
AC
>AC-3
>Rating, motor load switch [P]
>690 V [P]
1.8 W
AC
>AC-3
>Rated operational current motor load switch
>230 V [Ie]
0.2 CO
AC
>AC-3
>Rated operational current motor load switch
>400V 415 V [Ie]
> 0.3 x 106
AC
>AC-3
>Rated operational current motor load switch
>500 V [Ie ]
1200
AC
>AC-3
>Rated operational current motor load switch
>690 V [Ie]
7.5 kW
AC
>AC-21A
>Rated operational current switch
>440 V [Ie]
13 kW
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>230 V [P]
18.5 kW
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
15 kW
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
26.4 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
26.4 A
AC
>AC-23A
>Rated operational current motor load switch
>230 V [Ie]
23.4 A
AC
>AC-23A
>Rated operational current motor load switch
>400 V 415 V [Ie]
14.7 A
AC
>AC-23A
>Rated operational current motor load switch
>500 V [Ie]
32 A
AC
>AC-23A
>Rated operational current motor load switch
>690 V [Ie]
7.5 kW
DC
>DC-1, Load-break switches L/R = 1 ms
>Rated operational current [Ie]
15 kW
DC
>DC-1, Load-break switches L/R = 1 ms
>Voltage per contact pair in series
18.5 kW
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Rated operational current [Ie]
15 kW
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Contacts
32 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Rated operational current [Ie]
32 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Contacts
30 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Rated operational current [Ie]
19.8 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Contacts
32 A
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Rated operational current [Ie]
60 V
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Contacts
25 A
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 1 Quantity
Solid or stranded 25 A
Flexible with ferrules to DIN 46228 2 Quantity
Terminal screw 25 A
Tightening torque for terminal screw 2 Quantity
Notes 12 A
Contacts
>Rated operational voltage [Ue]
3 Quantity
Contacts
>Rated uninterrupted current max.
>Main conducting paths
>General use
< 10 -5, < 1 fault in 100000 operations HF
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>General Use [IU]
1 x (1,5 - 6)
2 x (1,5 - 6) mm2
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>Pilot Duty
1 x (1 - 4)
2 x (1 - 4) mm2
Switching capacity
>Maximum motor rating
>Single-phase
>120 V AC
M4
Switching capacity
>Maximum motor rating
>Single-phase
>200 V AC
1.6 Nm
Switching capacity
>Maximum motor rating
>Single-phase
>240 V AC
B10d values as per EN ISO 13849-1, table C1
Switching capacity
>Maximum motor rating
>Three-phase
>200 V AC
600 V AC
Switching capacity
>Maximum motor rating
>Three-phase
>240 V AC
30 A
Switching capacity
>Maximum motor rating
>Three-phase
>480 V AC
10 A
Switching capacity
>Maximum motor rating
>Three-phase
>600 V AC
A 600
P 600
Short Circuit Current Rating
>Basic Rating
1 HP
Short Circuit Current Rating
>max. Fuse
2 HP
Short Circuit Current Rating
>High fault rating
3 HP
Short Circuit Current Rating
>max. Fuse
3 HP
Terminal capacity
>Solid or flexible conductor with ferrule
7.5 HP
Terminal capacity
>Terminal screw
10 HP
Terminal capacity
>Tightening torque
15 HP
Rated operational current for specified heat dissipation [In] 5 kA
Heat dissipation per pole, current-dependent [Pvid] 110 A
Equipment heat dissipation, current-dependent [Pvid] 10 kA
Static heat dissipation, non-current-dependent [Pvs] 50, Class J A
Heat dissipation capacity [Pdiss] 14 - 8 AWG
Operating ambient temperature min. M4
Operating ambient temperature max. 14.1 lb-in
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
32 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
1.8 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-25 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+40 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components UV resistance only in connection with protective shield.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Version as main switch Is the panel builder´s responsibility.
Version as maintenance-/service switch Is the panel builder´s responsibility.
Version as safety switch Is the panel builder´s responsibility.
Version as emergency stop installation The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Version as reversing switch Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of switches Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. rated operation voltage Ue AC The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated operating voltage Yes
Rated permanent current Iu Yes
Rated permanent current at AC-23, 400 V No
Rated permanent current at AC-21, 400 V Yes
Rated operation power at AC-3, 400 V No
Rated short-time withstand current lcw 1
Rated operation power at AC-23, 400 V 690 V
Switching power at 400 V 690 - 690 V
Conditioned rated short-circuit current Iq 32 A
Number of poles 32 A
Number of auxiliary contacts as normally closed contact 32 A
Number of auxiliary contacts as normally open contact 13 kW
Number of auxiliary contacts as change-over contact 0.64 kA
Motor drive optional 15 kW
Motor drive integrated 15 kW
Voltage release optional 80 kA
Device construction 3
Suitable for ground mounting 1
Suitable for front mounting 4-hole 1
Suitable for front mounting centre 0
Suitable for distribution board installation No
Suitable for intermediate mounting No
Colour control element No
Type of control element Complete device in housing
Interlockable Yes
Type of electrical connection of main circuit No
Degree of protection (IP), front side No
Degree of protection (NEMA) No
Product Standards No
UL File No. Red
UL Category Control No. Door coupling rotary drive
CSA File No. Yes
CSA Class No. Screw connection
North America Certification IP65
Specially designed for North America 12
Suitable for UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
Degree of Protection E36332

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton