Interface module for NZM4 PXR25, connection for communication, zone selectivity, ARMS, neutral conductor voltageOptional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Breaker status modules - For multi purpose connection of optional circuit-breaker features. Required for communication. Type of connections depends on the version of the breaker status module. Detection of circuit-breaker status (I, +, 0) for the electronic release. Breaker status can be communicated. Auxiliary power supply connection for 2 x 24 V DC. Connection for communication adapter module (CAM). CAM available for various fieldbus communication systems (Profibus DP, SmartWire-DT, Ethernet based fieldbus). Connection to internal Modbus RTU module. Connection to Zone Selective Interlocking (ZSI). NZM3/4: Connection to arc reduction maintanance systems (ARMS). NZM4 3 pole: Connection to Vn voltage tap-off.
Interface module for NZM4 PXR25, connection for communication, zone selectivity, ARMS, neutral conductor voltage
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Breaker status modules - For multi purpose connection of optional circuit-breaker features. Required for communication. Type of connections depends on the version of the breaker status module. Detection of circuit-breaker status (I, +, 0) for the electronic release. Breaker status can be communicated. Auxiliary power supply connection for 2 x 24 V DC. Connection for communication adapter module (CAM). CAM available for various fieldbus communication systems (Profibus DP, SmartWire-DT, Ethernet based fieldbus). Connection to internal Modbus RTU module. Connection to Zone Selective Interlocking (ZSI). NZM3/4: Connection to arc reduction maintanance systems (ARMS). NZM4 3 pole: Connection to Vn voltage tap-off.
Product range | Accessories |
Accessories | Interface module |
Standard/Approval | UL/CSA, IEC |
Construction size | NZM4 |
Description | For universal connection of optional circuit breaker functions. Required for communication The connection types depend on the design of the interface module. Circuit breaker status detection (I, +, 0) for the electronic trip unit. The switch´s status can be communicated. 24 V DC auxiliary power connection. Connection for Communications Adapter Module (CAM). Optional CAM available for various Fieldbus communication systems (Profibus DP, SmartWire-DT, Ethernet-based Fieldbus). Connection to optional, internal Modbus RTU module. Connection to neutral voltage Vn. Connector for Logical Zone Selectivity (ZSI) function. Connection for maintenance mode (ARMS) Mechanical pass-through of the switch´s status (I, O) for use by the remote operator. |
Connection type | with push in terminal With bolt connection |
For use with | NZM4-PX…-TAZ |
Rated control voltage [Us
] >DC [Us ] |
24-24 V DC |
Rated control voltage [Us
] >Tolerance |
+/- 20% |
Rated control voltage [Us
] >max. current consumption |
100 |
Rated control voltage [Us
] >Connection >Connection type |
Screw terminal |
Rated control voltage [Us
] >Connection >Stripping length |
5 mm |
Rated control voltage [Us
] >Connection >Terminal capacity >Solid |
1 x (0.2 - 1.5) mm2 |
Rated control voltage [Us
] >Connection >Terminal capacity >Stranded |
1 x (0.2 - 1.5) mm2 |
Rated control voltage [Us
] >Connection >Terminal capacity |
1 x AWG 24 - AWG 16 AWG |
Rated control voltage [Us
] >Connection >Terminal capacity >with uninsulated end sleeve in accordance with DIN46228 / 1 |
1 x (0,25 - 0,75) mm2 |
Rated control voltage [Us
] >Connection >Terminal capacity >with insulated end sleeve in accordance with DIN46224 / 4 |
1 x (0,25 - 0,75) mm2 |
Rated control voltage [Us
] >Connection >Terminal capacity >Min. tightening torque |
0.22 Nm |
Rated control voltage [Us
] >Connection >Terminal capacity >Maximum tightening torque |
0.25 Nm |
Connection technique | 5-pin plug connector |
Connection type | assembled CAM cable |
Connection technique | 10-pin plug connector |
Connection type | pre-wired cable to the Modbus module |
Connection technique | Cable |
Connection type | Push-in |
Stripping length | 6 mm |
Terminal capacity >Solid |
1 x (0.2 - 0.5) mm2 |
Terminal capacity >Stranded |
1 x (0.2 - 0.5) mm2 |
Terminal capacity >with uninsulated end sleeve in accordance with DIN46228 / 1 |
1 x (0,25 - 0,5) mm2 |
Digitale Halbleiterausgänge >Function |
For remote switching |
Digitale Halbleiterausgänge >Number |
1 |
Digitale Halbleiterausgänge >Output voltage |
3,3 V DC |
Digitale Halbleiterausgänge >Overload proof |
yes |
Digitale Halbleiterausgänge >Connection technique |
Cable |
Digitale Halbleiterausgänge >Connection type |
Push-in |
Digitale Halbleiterausgänge >Stripping length |
6 mm |
Digitale Halbleiterausgänge >Terminal capacity >Solid |
1 x (0,2 - 0,5) mm2 |
Digitale Halbleiterausgänge >Terminal capacity >Stranded |
1 x (0,2 - 0,5) mm2 |
Digitale Halbleiterausgänge >Terminal capacity >with uninsulated end sleeve in accordance with DIN46228 / 1 |
1 x (0,25 - 0,5) mm2 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Type of accessory | Communication and measuring function |
Product Standards | In preparation |
Degree of Protection | Installation in the switch |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.