NZM3-XR208-240AC
259850 NZM3-XR208-240AC
259850

Remote operator, 208-240VAC, for size 3Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: for remote switching of circuit-breakers and switch-disconnectors. ON and OFF switching and resetting by means of two-wire or three-wire control. Local switching by hand possible. lockable in the 0 position of the remote operator with up to 3 padlocks (hasp thickness: 4–8mm). Can be synchronized. Cannot be combined with mechanical interlock. Cannot be combined with dual auxiliary switch M22-CK11. Can be used for: NZM3(-4), N(N/O)3(-4)

Remote operator, 208-240VAC, for size 3
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: for remote switching of circuit-breakers and switch-disconnectors. ON and OFF switching and resetting by means of two-wire or three-wire control. Local switching by hand possible. lockable in the 0 position of the remote operator with up to 3 padlocks (hasp thickness: 4–8mm). Can be synchronized. Cannot be combined with mechanical interlock. Cannot be combined with dual auxiliary switch M22-CK11. Can be used for: NZM3(-4), N(N/O)3(-4)

Product range Accessories
Accessories Remote operator, can be synchronized
Rated operating frequency AC 50/60 Hz
Standard/Approval UL/CSA, IEC
Construction size NZM3
Description

For remote switching of circuit-breakers and switch-disconnectors.

ON and OFF switching and resetting by means of two-wire or three-wire control.

Local switching by hand possible.

Lockable in the 0 position of the remote operator with up to 3 padlocks (hasp thickness: 4 – 8 mm)

Can be synchronized

 Please note during engineering:
Three-wire controlTerminal 70/71:
  NZM-XR: Contact loading according to technical data
NZM2-XRD: Full current flows through the contact during make and break!
RMQ series contact elements can be used for the NZM2(3.4)-XR(D)...remote operators.
 
  
Two-wire controlTerminal 75:
  NZM-XR: Operational readiness signal when cover closed and not locked.
NZM2-XRD: Operational readiness signal when sliding switch set to Auto.
Sliding switch with three positions: Manual/Auto/Locked for reliable
differentiation of connected positions.
AC-15: 400 V; 2 A
DC-13: 220 V; 0.2 A
  
Three-wire control with automatic reset to the 0 position after the switch has tripped
   
 
Switching cycle: 
NZM2-XR
NZM3-XR
NZM4-XR
The time interval between OFF and ON is 3 seconds. On commands received during the time interval are ignored within the first 3 seconds after switch off.
  
Parallel remote operator connection
   
  
Closing delay 80 ms
Break time 1000 ms
Rated control voltage [Us] 208 - 240 V 50/60 Hz V
Number of poles 3/4 pole
For use with NZM3(-4)
N(S)3(-4)
Project planning information Cannot be combined with switch-disconnector PN...
M22-CK11(20/02) dual auxiliary switch cannot be combined with NZM3-XR… remote operator
Engineering information (sheet catalog) 2/3-wire control and circuit diagrams
Rated control voltage [Us ]
>AC [Us ]
208-240 V AC
Operating range
>AC
0.85 - 1.1 x Us
Operating range
>DC
0.85 - 1.1 x Us
Motor rating
>AC
>110 V … 130 V AC [S]
350 VA
Minimum signal duration
>with switch on
30 ms
Minimum signal duration
>with switch off
250 ms
Lifespan, mechanical [Operations] 15000
Maximum operating frequency
>Max. operating frequency
60 Ops/h
Terminal capacities
>Solid or flexible conductor, with ferrule
0,75 - 2,5 mm2
Terminal capacities 18 … 14 AWG
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Type of switch drive Motor drive
Rated control supply voltage Us at AC 50HZ 208 - 240 V
Rated control supply voltage Us at AC 60HZ 208 - 240 V
Rated control supply voltage Us at DC 0 - 0 V
Voltage type for actuating AC
Product Standards UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking
UL File No. E140305
UL Category Control No. DIHS
CSA File No. 022086
CSA Class No. 1437-01
North America Certification UL listed, CSA certified

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.