Link kit, +insulating plates, 4p, /2pOptional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for upper switch side for 4 pole switches N...-S1-DC that are used as 2 pole switches for DC. The links each connect 2 contacts in series. Incoming unit and outgoer at bottom or top, user-definable. = 1250A: for 65 °C ambient air temperature connection at bottom through module plates NZM4-4-XKM2S-1600. Use jumper kit with insulating plates and phase isolator Can be used for: N3-400(500)-S1-DC
Link kit, +insulating plates, 4p, /2p
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for upper switch side for 4 pole switches N...-S1-DC that are used as 2 pole switches for DC. The links each connect 2 contacts in series. Incoming unit and outgoer at bottom or top, user-definable. = 1250A: for 65 °C ambient air temperature connection at bottom through module plates NZM4-4-XKM2S-1600. Use jumper kit with insulating plates and phase isolator Can be used for: N3-400(500)-S1-DC
Number of poles | 2 pole |
Accessories | DC link kit |
Number of conductors | 4 |
Rated current [In] | Jumper kit with insulating plates/phase isolator IP00 |
For use with | 534 (40 °C,) 451 (65 °C) A |
Notes | N3-4-…-S1(-S15)-DC |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Model contains parts for upper switch side for 4 pole switches N...-DC that are used as 2 pole switches for DC. The links each connect contacts in series. Incoming unit and outgoer at bottom or top, user-definable. See figure connection type. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Suitable for number of poles | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Model | 4 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.