alt
alt

NZM2/3-XA2A208-240AC
189743 NZM2/3-XA2A208-240AC
189743

Shunt release for NZM2/3, configurable relays, 2NO, 208-240AC, Push-in terminalsOptional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Shunt releases with two relays. Switches are tripped by a voltage pulse or by the application of uninterrupted voltage. For signalizing commands or different states of the circuit-breaker. Two relays per unit. Actuation reason can be configured in the trip unit. Configuration via communication or circuit breaker display or front USB connection and Eaton Power Xpert Protection Manager. When the shunt release is live, contact with the circuit-breaker´s main contacts on switching on is reliably prevented. Only suitable for use in conjunction with circuit-breakers with electronic releases. Shunt release relais modules cannot be installed simultaneously with early-make contact NZM…-XHIV, or untervoltage release NZM…-XU…, or shunt release NZM…-XA… Relay coil actuated by trip unit. Relay contact for control wiring. Control wiring to push-in terminals. Cannot be used with PXR10 NZM-AE electronic release.

Shunt release for NZM2/3, configurable relays, 2NO, 208-240AC, Push-in terminals
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Shunt releases with two relays. Switches are tripped by a voltage pulse or by the application of uninterrupted voltage. For signalizing commands or different states of the circuit-breaker. Two relays per unit. Actuation reason can be configured in the trip unit. Configuration via communication or circuit breaker display or front USB connection and Eaton Power Xpert Protection Manager. When the shunt release is live, contact with the circuit-breaker´s main contacts on switching on is reliably prevented. Only suitable for use in conjunction with circuit-breakers with electronic releases. Shunt release relais modules cannot be installed simultaneously with early-make contact NZM…-XHIV, or untervoltage release NZM…-XU…, or shunt release NZM…-XA… Relay coil actuated by trip unit. Relay contact for control wiring. Control wiring to push-in terminals. Cannot be used with PXR10 NZM-AE electronic release.

Product range Accessories
Accessories Shunt release
Accessories Shunt release with two relays
Standard/Approval UL/CSA, IEC
Construction size NZM2/3
Description The breakers are actuated by a voltage pulse or by applying a no-break current.
For signalizing commands or different states of the circuit-breaker.
Two relays per unit.
The activation criteria can be configured in the trip unit.
Configuration via communication or circuit breaker display or front USB port and Eaton Power Xpert Protection Manager.
If the shunt trip is live, contact with the circuit breaker’s primary contacts is prevented when switched on.
Only for use in combination with circuit-breakers with electronic trips.
Shunt trip relay modules cannot be installed simultaneously with make-before-break auxiliary contact NZM...-XHIV, under-voltage trip NZM...-XU... or shunt trip NZM...-XA.
Relay coil is controlled by trip unit.
Relay contacts for control wiring.
Relays can be used for controlling remote operator with Us=208-204 V AC.
Control wiring on push-in clamps.
Cannot be used with the PXR10 NZM-AX electronic trip.
Connection type with push in terminal
Auxiliary contacts without auxiliary contact
For use with PXR20(25) NZM2(-4)-..X…
PXR20(25) NZM3(-4)-..X…
Number of relays 2
Contact sequence 1230SWI-146
Rated control voltage [Us ]
>AC [Us ]
208-240 V AC
Operating range
>AC [x Us]
0.7 - 1.1
Operating range
>DC [x Us]
0.7 - 1.1
Power consumption
>Pick-up AC/DC
2.5 VA/W
Power consumption
>Power consumption Pick-up = Sealing
2.5 VA/W
Maximum opening delay (response time until opening of the main contacts) Approx. 20 ms
Maximum duty factor ∞ ms
Minimum command time Approx. 10 … 15 ms
Terminal capacity
>Solid
1 x (0.2 – 1.5) mm2
Terminal capacity
>Stranded
1 x (0.25 – 1.5) mm2
Terminal capacity 1 x (24 - 16) AWG
Terminal capacity
>with insulated end sleeve in accordance with DIN46224 / 4
1 x (0,25 - 1,5) mm2
Terminal capacity
>with uninsulated end sleeve in accordance with DIN46228 / 1
1 x (0,25 - 0,75) mm2
Rated control voltage [Us ]
>AC [Us ]
24-240 V AC
Rated control voltage [Us ]
>DC [Us ]
24-24 V DC
Contacts
>Rated impulse withstand voltage [Uimp]
4000 V AC
Contacts
>Rated insulation voltage [Ui ]
250 V
Contacts
>Overvoltage category/pollution degree
II/2
Switching capacity
>Rated operational current
>AC–1
>24 V [Ie]
1 A
Switching capacity
>Rated operational current
>AC–1
>110 V [Ie]
1 A
Switching capacity
>Rated operational current
>AC–1
>230 V [Ie]
1 A
Switching capacity
>Rated operational current
>DC-1
>24 V [Ie ]
1 A
Switching capacity
>Min. switching capacity (reference value)
0.1 mA / 0.1 VDC
Connection
>Stripping length
8 mm
Connection
>Terminal capacity
>Solid
1 x (0.2 – 1.5) mm2
Connection
>Terminal capacity
>Stranded
1 x (0.25 – 1.5) mm2
Connection
>Terminal capacity
1 x (24 - 16) AWG
Connection
>Terminal capacity
>with insulated end sleeve in accordance with DIN46224 / 4
1 x (0,25 - 1,5) mm2
Connection
>Terminal capacity
>with uninsulated end sleeve in accordance with DIN46228 / 1
1 x (0,25 - 0,75) mm2
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated control supply voltage Us at AC 50HZ 208 - 250 V
Rated control supply voltage Us at AC 60HZ 208 - 250 V
Rated control supply voltage Us at DC 0 - 0 V
Voltage type for actuating AC
Initial value of the undelayed short-circuit release - setting range 0 A
End value adjustment range undelayed short-circuit release 0 A
Type of electric connection Spring clamp connection
Number of contacts as normally open contact 2
Number of contacts as normally closed contact 0
Number of contacts as change-over contact 0
Suitable for power circuit breaker Yes
Suitable for off-load switch Yes
Suitable for motor safety switch Yes
Suitable for overload relay No
Product Standards UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking
UL File No. E140305
UL Category Control No. DIHS
CSA File No. 022086
CSA Class No. 1437-01
North America Certification UL listed, CSA certified

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

NZMH2-4-VX250/VAR
Eaton
NZMH2-VX250-SVE
Eaton
NZMS2-4-VX250/VAR
Eaton
NZMS2-4-VX160
Eaton
NZMS2-MX220-SVE
Eaton
NZMS2-VX250-SVE
Eaton
NZMN2-4-VX160/VAR
Eaton
NZMN2-VX100-BT
Eaton