Fieldbus connection, profibus-DPV1-SlaveOptional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: connection to the DMI module. Transfer of phase currents, parameter data, status data and diagnostics data. Transfer of circuit-breaker position (wiring of auxiliary contacts to DMI inputs). Actuation of the DMI motor starter functions and the NZM remote operator. detection of digital inputs and actuation via field Bus. PROFIBUS-DPV1 slave fieldbus connection. Can be operated with class 1 and class 2 masters. Addressable 1 to 126. Can be used for: NZM2, NZM2-4, NZM3, NZM3-4, NZM4, NZM4-4
Fieldbus connection, profibus-DPV1-Slave
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: connection to the DMI module. Transfer of phase currents, parameter data, status data and diagnostics data. Transfer of circuit-breaker position (wiring of auxiliary contacts to DMI inputs). Actuation of the DMI motor starter functions and the NZM remote operator. detection of digital inputs and actuation via field Bus. PROFIBUS-DPV1 slave fieldbus connection. Can be operated with class 1 and class 2 masters. Addressable 1 to 126. Can be used for: NZM2, NZM2-4, NZM3, NZM3-4, NZM4, NZM4-4
Product range | Accessories |
Accessories | Diagnostics, communication |
Description | Connection to the DMI module
|
Bus protocol | PROFIBUS-DP |
Notes | Connected to the DMI module and has the same contour appearance. |
Standards | EN 55011, EN 55022, IEC/EN 61000-4, IEC 60068-2-6, IEC 60068-2-27 |
Dimensions (W x H x D) | 35.5 x 90 x 58 (2 PE) mm |
Weight | 0.15 kg |
Mounting | Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories) |
Solid | 0.2 … 4 (AWG 22 … 12) mm2 |
Flexible with ferrule | 0.2 … 2.5 (AWG 22 … 12) mm2 |
Standard screwdriver | 0.8 x 3.5 mm |
Max. tightening torque | 0.6 Nm |
Operating ambient temperature | -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C |
Condensation | Take appropriate measures to prevent condensation |
Storage | - 40 - 70 °C |
Relative humidity, non-condensing (IEC/EN 60068-2-30) | 5 - 95 % |
Air pressure (operation) | 795 - 1080 hPa |
Corrosion resistance >IEC/EN 60068-2-42 [4 days SO2] |
10 cm3/m3 |
Corrosion resistance >IEC/EN 60068-2-43 [4 days H2S] |
1 cm3/m3 |
Pollution degree | 2 |
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP20 |
Vibrations (IEC/EN 60068-2-6) >Constant amplitude 0.15 mm |
10 - 57 Hz |
Vibrations (IEC/EN 60068-2-6) >Constant acceleration 2 g |
57 - 150 Hz |
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms | 18 Impacts |
Drop to IEC/EN 60068-2-31 [Drop height] | 50 mm |
Free fall, packaged (IEC/EN 60068-2-32) | 1 m |
Mounting position | Vertical or horizontal |
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD) >Air discharge |
8 kV |
Electrostatic discharge (IEC/EN 61000-4-2, Level 3, ESD) >Contact discharge |
6 kV |
Electromagnetic fields (RFI) to IEC EN 61000-4-3 | 10 V/m |
Radio interference suppression | EN 55011 Class B, EN 55022 Class B |
Burst Impulse (IEC/EN 61000-4-4, Level 3) >Supply cable |
2 kV |
Burst Impulse (IEC/EN 61000-4-4, Level 3) >Signal lines |
2 kV |
power pulses (surge) (IEC/EN 61000-4-5, level 2) | 0.5 (supply cables, symmetrical) kV |
Immunity to line-conducted interference to (IEC/EN 61000-4-6) | 10 V |
Clearance in air and creepage distances | EN 50178, UL 508, CSA C22.2, No. 142 |
Insulation resistance | EN 50178 |
Rated operational voltage [Ue] | 24 (-15/+20 %) V |
Admissible range | 20.4 - 28.8 V DC |
Residual ripple | < 5 % |
at 24 V DC | Normally 200 mA |
Voltage dips | ≤ 10 ms |
Heat dissipation at 24 V DC | 4.8 W |
AS-I power supply | Yes |
Supply | Power LED (POW): green |
LED display | PROFIBUS-DP LED (BUS): red |
Connection technique | SUB-D 9 pole, socket |
Potential isolation | Between bus and power supply (simple), between bus and power supply and NZM-XDMI612 (safe isolation) |
Function | PROFIBUS-DP slave |
Interface | RS485 |
Bus protocol | PROFIBUS-DP |
Baud rates | Automatic search up to 12 MBit⁄s |
Bus terminating resistors | Separate external bus termination required |
Bus addresses | 1 … 126 via DMI |
Services >Cyclic |
Status ON/OFF/tripped (detailed), load early warnings, phase currents I1/I2/I3 [A], remote operator actuation, display/operation NZM-XDMI612 inputs/outputs, motor starter functions |
Services >Acyclic |
Display/match protection settings, event list, identification, hours of operation, switching operations, time |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Supply voltage AC 50 Hz | 0 - 0 V |
Supply voltage AC 60 Hz | 0 - 0 V |
Supply voltage DC | 0 - 0 V |
Voltage type of supply voltage | DC |
Supporting protocol for TCP/IP | No |
Supporting protocol for PROFIBUS | Yes |
Supporting protocol for CAN | No |
Supporting protocol for INTERBUS | No |
Supporting protocol for ASI | No |
Supporting protocol for KNX | No |
Supporting protocol for MODBUS | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for SERCOS | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
IO link master | No |
System accessory | Yes |
Degree of protection (IP) | IP20 |
With potential separation | No |
Fieldbus connection over separate bus coupler possible | No |
Rail mounting possible | Yes |
Wall mounting/direct mounting | No |
Front build in possible | Yes |
Rack-assembly possible | No |
Suitable for safety functions | No |
Category according to EN 954-1 | |
SIL according to IEC 61508 | None |
Performance level acc. EN ISO 13849-1 | None |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Explosion safety category for gas | None |
Explosion safety category for dust | Other |
Width | 36 mm |
Height | 90 mm |
Depth | 60 mm |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.