alt
alt

NZM-XCM
229413 NZM-XCM
229413

Shunt release, for capacitor unitOptional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: capacitor unit 230 V 50/60 Hz in conjunction with NZM...-XA208-250 AC/DC shunt release. Enclosure: degree of protection IP20. Not UL/CSA approved. enables the safe use of circuit-breakers as mesh network circuit-breakers in the range from 0–110 % Un with constant switch-off time of 40ms. If the mains voltage is absent, the installed capacitor supplies power for actuating the shunt release for at least 12 hours. The configuration of the capacitor unit is undertaken independently of the circuit-breaker. Connect capacitor unit to the supply side. engineering Guidelines: Connect a standard auxiliary contact (HIN) as N/O in series with the shunt release! Standard auxiliary contact not included as standard. Can be used for: NZM1(-4), N(N/O)1(-4), NZM2(-4), N(N/O)2(-4), NZM3(-4), N(N/O)3(-4), NZM4(-4), N(N/O)4(-4)

Shunt release, for capacitor unit
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: capacitor unit 230 V 50/60 Hz in conjunction with NZM...-XA208-250 AC/DC shunt release. Enclosure: degree of protection IP20. Not UL/CSA approved. enables the safe use of circuit-breakers as mesh network circuit-breakers in the range from 0–110 % Un with constant switch-off time of 40ms. If the mains voltage is absent, the installed capacitor supplies power for actuating the shunt release for at least 12 hours. The configuration of the capacitor unit is undertaken independently of the circuit-breaker. Connect capacitor unit to the supply side. engineering Guidelines: Connect a standard auxiliary contact (HIN) as N/O in series with the shunt release! Standard auxiliary contact not included as standard. Can be used for: NZM1(-4), N(N/O)1(-4), NZM2(-4), N(N/O)2(-4), NZM3(-4), N(N/O)3(-4), NZM4(-4), N(N/O)4(-4)

Product range Accessories
Accessories Shunt release
Accessories Shunt releases Capacitor unit
Standard/Approval IEC
Construction size NZM1/2/3/4
Description Capacitor unit 230 V 50/60 Hz in conjunction with NZM...-XA208-250 AC/DC shunt release
Enclosure: degree of protection IP20
not UL/CSA approved
Enables the safe use of circuit-breakers as mesh network circuit-breakers in the range from 0 – 110 % Un with constant switch-off time of 40 ms.
If the mains voltage is absent, the installed capacitor supplies power for actuating the shunt release for at least 12 hours.
The configuration of the capacitor unit is undertaken independently of the circuit-breaker.
Connect capacitor unit to the supply side!
Engineering Guidelines: Connect a standard auxiliary contact as N/O in series with the shunt release!
Standard auxiliary contact not included as standard.
For use with NZM1(-4), N(S)1(-4)
NZM2(-4), N(S)2(-4)
NZM3(-4), N(S)3(-4)
NZM4(-4), N(S)4(-4)
Contact sequence 123S019
Rated operational voltage [Ue ] 230 V AC
Rated operational current [Ie ] < 10 mA
Inrush current (peak value) [Ie] 3 A
Terminal capacities
>Solid or flexible conductor, with ferrule
1 x (0,5 - 2,5) mm2
Terminal capacities 1 x (20 - 14)
2 x (20 - 16) AWG
Overvoltage category/pollution degree III/3
Main contacts 8000 V
Auxiliary contacts 8000 V
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated control supply voltage Us at AC 50HZ 230 - 230 V
Rated control supply voltage Us at AC 60HZ 230 - 230 V
Rated control supply voltage Us at DC 0 - 0 V
Voltage type for actuating DC
Initial value of the undelayed short-circuit release - setting range 0 A
End value adjustment range undelayed short-circuit release 0 A
Type of electric connection Screw connection
Number of contacts as normally open contact 0
Number of contacts as normally closed contact 0
Number of contacts as change-over contact 0
Suitable for power circuit breaker Yes
Suitable for off-load switch Yes
Suitable for motor safety switch No
Suitable for overload relay No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

NZMH2-4-VX250/VAR
Eaton
NZMH2-VX250-SVE
Eaton
NZMS2-4-VX250/VAR
Eaton
NZMS2-4-VX160
Eaton
NZMS2-MX220-SVE
Eaton
NZMS2-VX250-SVE
Eaton
NZMN2-4-VX160/VAR
Eaton
NZMN2-VX100-BT
Eaton