Molded Case Switch, 3p, 800AMolded Case Switch, N4, Switch-disconnectors, 3 pole, Switching capacity SCCR 480Y/277 V 60 Hz Icu: 65 kA, S Switching capacity SCCR 600Y/347 V 60 Hz Icu: 42 kA, Rated current = rated uninterrupted current In = Iu: 800 A, Rated current = rated uninterrupted current In = Iu: 800 A, Standard/Approval: UL/CSA, IEC, Installation type: Fixed, Screw connection, Protective function: Disconnectors/main switches
Molded Case Switch, 3p, 800A
Molded Case Switch, N4, Switch-disconnectors, 3 pole, Switching capacity SCCR 480Y/277 V 60 Hz Icu: 65 kA, S Switching capacity SCCR 600Y/347 V 60 Hz Icu: 42 kA, Rated current = rated uninterrupted current In = Iu: 800 A, Rated current = rated uninterrupted current In = Iu: 800 A, Standard/Approval: UL/CSA, IEC, Installation type: Fixed, Screw connection, Protective function: Disconnectors/main switches
Product range | Switch-disconnectors |
Protective function | Disconnectors/main switches |
Standard/Approval | UL/CSA, IEC |
Installation type | Fixed |
Construction size | N4 |
Description | IEC/EN 60947-2: Circuit-breakers without overcurrent (CBI-X) with main switch characteristics and isolating characteristics to IEC/EN 60204. |
Number of poles | 3 pole |
Standard equipment | Screw connection |
Switch positions | I, +, 0 |
Rated current = rated uninterrupted current [In = Iu] | 800 A |
Rated current = rated uninterrupted current [In = Iu] | 800 A |
SCCR 480Y/277 V 60 Hz [Icu] | 65 kA |
SCCR 480 V 60 Hz [Icu] | 65 kA |
SCCR 600Y/347 V 60 Hz [Icu] | 42 kA |
SCCR 600 V 60 Hz [Icu] | 42 kA |
Non-delayed [Ii = In x …] | 25000 A fixed |
Rated surge voltage invariability [Uimp
] >Main contacts |
8000 V |
Rated surge voltage invariability [Uimp
] >Auxiliary contacts |
6000 V |
Rated operational voltage [Ue] | 690 V AC |
Rated current = rated uninterrupted current [In = Iu] | 800 A |
Rated current = rated uninterrupted current [In = Iu] | 800 A |
Rated uninterrupted current [Iu
] >IEC/EN 61131-3 [Iu ] |
1200 A |
Rated uninterrupted current [Iu
] >UL 489, CSA 22.2 No. 5.1 [Iu ] |
1200 A |
Overvoltage category/pollution degree | III/3 |
Rated insulation voltage [Ui ] | 1000 V |
Other technical data (sheet catalogue) | Weight Temperature dependency, Derating Effective power loss |
Ambient temperature >Ambient temperature, storage |
- 40 - + 70 °C |
Ambient temperature >Operation |
-25 - +70 °C |
Mounting position | |
Direction of incoming supply | as required |
Degree of protection >Device |
In the area of the HMI devices: IP20 (basic protection type) |
Degree of protection >Enclosures |
With insulating surround: IP40 With door coupling rotary handle: IP66 |
Degree of protection >Terminations |
Tunnel terminal: IP10 Phase isolator and band terminal: IP00 |
SCCR 240 V 60 Hz [Icu] | 125 kA |
SCCR 480Y/277 V 60 Hz [Icu] | 65 kA |
SCCR 480 V 60 Hz [Icu] | 65 kA |
SCCR 600Y/347 V 60 Hz [Icu] | 42 kA |
SCCR 600 V 60 Hz [Icu] | 42 kA |
240 V 50/60 Hz [Icm ] | 187 kA |
400/415 V 50/60 Hz [Icm ] | 154 kA |
440 V 50/60 Hz [Icm ] | 143 kA |
525 V 50/60 Hz [Icm ] | 84 kA |
690 V 50/60 H [Ic] | 74 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >240 V 50/60 Hz [Icu ] |
85 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >400/415 V 50 Hz [Icu ] |
70 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >440 V 50/60 Hz [Icu ] |
65 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >525 V 50/60 Hz [Icu ] |
40 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >690 V 50/60 Hz [Icu ] |
35 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >230 V 50/60 Hz [Ics ] |
43 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >400/415 V 50/60 Hz [Ics ] |
35 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >440 V 50/60 Hz [Ics ] |
33 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >525 V 50/60 Hz [Ics ] |
20 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >690 V 50/60 Hz [Ics] |
18 kA |
Lifespan, mechanical [Operations] | 10000 |
Max. operating frequency | 60 Ops/h |
400 V 50/60 Hz [Operations] | 3000 |
415 V 50/60 Hz [Operations] | 2000 |
690 V 50/60 Hz [Operations] | 2000 |
400 V 50/60 Hz [Operations] | 2000 |
415 V 50/60 Hz [Operations] | 2000 |
690 V 50/60 Hz [Operations] | 1000 |
Standard equipment | < 25 ≦ 415 V; < 35 > 415 V ms |
Optional accessories | Screw connection |
Copper conductors and cables >Tunnel terminal >Stranded >4-hole |
Tunnel terminal connection on rear Strip terminal |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >Stranded |
4 x (50 - 240) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >Single hole [min.] |
1 x (120 - 185) 4 x (50 - 185) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >Single hole [max.] |
1 x (120 - 300) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >Double hole [min.] |
2 x (95 - 300) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >Double hole [max.] |
2 x (95 - 185) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Connection width extension >Connection width extension |
4 x (35 - 185) mm2 |
Al conductors, Al cable >Tunnel terminal >Stranded >4-hole |
4 x 300 6 x (95 - 240) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Module plate >Single hole [min.] |
4 x (50 - 240) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Module plate >Single hole [max.] |
1 x (185 - 240) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Module plate >Double hole |
2 x (70 - 185) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Connection width extension >Connection width extension |
4 x 50 mm2 |
Cu strip (number of segments x width x segment thickness) >Flat conductor terminal [min.] |
2 x 240 6 x (70 - 240) mm2 |
Cu strip (number of segments x width x segment thickness) >Flat conductor terminal [max.] |
6 x 16 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) >Module plate >Single hole |
(2 x) 10 x 32 x 1.0 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [min.] |
(2 x) 10 x 50 x 1.0 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [max.] |
(2 x) 10 x 50 x 1.0 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Connection width extension |
(2 x) 10 x 50 x 1.0 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Screw connection |
(2 x) 10 x 80 x 1.0 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [min.] |
M10 |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [max.] |
25 x 5 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Module plate >Single hole [min.] |
2 x (50 x 10) mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Module plate >Single hole [max.] |
25 x 5 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Module plate >Double hole |
2 x (50 x 10) mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Connection width extension >Connection width extension [min.] |
2 x (50 x 10) mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Connection width extension >Connection width extension [max.] |
60 x 10 mm |
Copper conductors and cables >Tunnel terminal >Stranded >4-hole |
2 x (80 x 10) mm |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >1-hole [Min.] |
4 x (0 - 500) AWG/kcmil |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >1-hole [Max.] |
1 x (250 - 600) AWG/kcmil |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >2-hole [Min.] |
2 x (3/0 - 600) AWG/kcmil |
Copper conductors and cables >Bolt terminal and rear-side connection >Module plate >2-hole [Max.] |
2 x (3/0 - 350) AWG/kcmil |
Copper conductors and cables >Bolt terminal and rear-side connection >Connection width extension >Connection width extension |
4 x (2 - 350) AWG/kcmil |
Cu strip (number of segments x width x segment thickness) >Flat conductor terminal [min.] |
4 x 600 6 x (3/0 - 500) AWG/kcmil |
Cu strip (number of segments x width x segment thickness) >Flat conductor terminal [max.] |
6 x 16 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) >Module plate >Single hole |
(2 x) 10 x 32 x 1.0 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [min.] |
(2 x) 10 x 50 x 1.0 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [max.] |
(2 x) 10 x 50 x 1.0 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Connection width extension |
(2 x) 10 x 50 x 1.0 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Screw connection |
(2 x) 10 x 80 x 1.0 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [min.] |
M10 |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [max.] |
25 x 5 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Module plate >Single hole [min.] |
2 x (50 x 10) mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Module plate >Single hole [max.] |
25 x 5 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Module plate >Double hole |
2 x (50 x 10) mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Connection width extension >Connection width extension [min.] |
2 x (50 x 10) mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Connection width extension >Connection width extension [max.] |
60 x 10 mm |
Rated operational current for specified heat dissipation [In] | 2 x (80 x 10) mm |
Equipment heat dissipation, current-dependent [Pvid] | 800 A |
Operating ambient temperature min. | 71.04 W |
Operating ambient temperature max. | -25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+70 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated permanent current Iu | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated voltage | 800 A |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | 690 - 690 V |
Overload release current setting | 70 kA |
Adjustment range short-term delayed short-circuit release | 0 - 0 A |
Adjustment range undelayed short-circuit release | 0 - 0 A |
Integrated earth fault protection | 25000 - 25000 A |
Type of electrical connection of main circuit | No |
Device construction | Screw connection |
Suitable for DIN rail (top hat rail) mounting | Built-in device fixed built-in technique |
DIN rail (top hat rail) mounting optional | No |
Number of auxiliary contacts as normally closed contact | Yes |
Number of auxiliary contacts as normally open contact | 0 |
Number of auxiliary contacts as change-over contact | 0 |
With switched-off indicator | 0 |
With under voltage release | No |
Number of poles | No |
Position of connection for main current circuit | 3 |
Type of control element | Front side |
Complete device with protection unit | Rocker lever |
Motor drive integrated | Yes |
Motor drive optional | No |
Degree of protection (IP) | Yes |
Product Standards | IP20 |
UL File No. | UL 489; CSA-C22.2 No. 5-09; IEC 60947-2; CE marking |
UL Category Control No. | E148671 |
CSA File No. | WJAZ |
CSA Class No. | 022086 |
North America Certification | 4652-06 |
Specially designed for North America | UL listed, CSA certified |
Suitable for | Yes |
Current Limiting Circuit-Breaker | Feeder circuits, branch circuits |
Max. Voltage Rating | No |
Degree of Protection | 600 V |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.